SearcharxivSearch

arXiv subjects

N. Hughes

Publications and source records attributed to N. Hughes.

10 recordsLinked to original sources

Buoy measurements of strong waves in ice amplitude modulation: a signature of complex physics governing waves in ice attenuation

The Marginal Ice Zone (MIZ) forms a critical transition region between the ocean and sea ice cover as it protects the close ice further in from the effect of the steepest and most energetic open ocean waves. As waves propagate through the MIZ, they get exponentially attenuated. Unfortunately, the associated attenuation coefficient is difficult to accurately estimate and model, and there are still large uncertainties around which attenuation mechanisms dominate depending on the conditions. This makes it challenging to predict waves in ice attenuation, as well as sea ice breakup and dynamics. Here, we report in-situ observations of strongly modulated waves-in-ice amplitude, with a modulation period of around 12 hours. We show that simple explanations, such as changes in the incoming open water waves, or the effect of tides and currents and bathymetry, cannot explain for the observed modulation. Therefore, the significant wave height modulation observed in the ice most likely comes from a modulation of the waves-in-ice attenuation coefficient. To explain this, we conjecture that one or several waves-in-ice attenuation mechanisms are periodically modulated and switched on and off in the area of interest. We gather evidence that sea ice convergence and divergence is likely the factor driving this change in the waves in ice attenuation mechanisms and attenuation coefficient, for example by modulating the intensity of floe-floe interaction mechanisms.

physics.ao-ph

Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance

The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.

astro-ph.CO

Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.

astro-ph.IM

Noise Properties of the Planck-LFI Receivers

The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.

astro-ph.IM

The linearity response of the Planck-LFI flight model receivers

In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best parameter set representing the receiver response and discuss the impact of non linearity on in-flight calibration, which is shown to be negligible.

astro-ph.IM

Advanced modelling of the Planck-LFI radiometers

The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic microwave background (CMB) with unprecedented precision. In this paper we describe the development and validation of a software model of the LFI pseudo-correlation receivers which enables to reproduce and predict all the main system parameters of interest as measured at each of the 44 LFI detectors. These include system total gain, noise temperature, band-pass response, non-linear response. The LFI Advanced RF Model (LARFM) has been constructed by using commercial software tools and data of each radiometer component as measured at single unit level. The LARFM has been successfully used to reproduce the LFI behavior observed during the LFI ground-test campaign. The model is an essential element in the database of LFI data processing center and will be available for any detailed study of radiometer behaviour during the survey.

astro-ph.IM

Cryogenic environment and performance for testing the Planck radiometers

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In this paper the facilities and the related instrumentation are described. The main satellite thermal interfaces for the single chains have to be reproduced and stability requirements have to be satisfied. Setup design, problems occurred and improving solutions implemented are discussed. Performance of the cryogenic setup are reported.

astro-ph.IM

Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.

astro-ph.IM

Planck pre-launch status: Design and description of the Low Frequency Instrument

In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.

astro-ph.IM

Advanced pseudo-correlation radiometers for the Planck-LFI instrument

The LFI (Low Frequency Instrument) on board the ESA Planck satellite is constituted by an array of radiometric detectors actively cooled at 20 K in the 30-70 GHz frequency range in the focal plane of the Planck telescope. In this paper we present an overview of the LFI instrument, with a particular focus on the radiometer design. The adopted pseudo-correlation scheme uses a software balancing technique (with a tunable parameter called gain modulation factor) which is effective in reducing the radiometer susceptibility to amplifier instabilities also in presence of small non-idealities in the radiometric chain components, provided that the gain modulation factor is estimated with an accuracy of the order of 0.2%. These results have been recently confirmed by experimental laboratory measurements conducted on the LFI prototype radiometers at 30, 70 and 100 GHz.

astro-ph