SearcharxivSearch

arXiv subjects

N. Meidinger

Publications and source records attributed to N. Meidinger.

14 recordsLinked to original sources

The SRG/eROSITA All-Sky Survey DR2: Cumulative X-ray catalogues from the first three surveys and multi-wavelength counterparts in the western Galactic hemisphere

The eROSITA telescope array on board the Spektrum-Roentgen-Gamma (SRG) mission began its all-sky survey program in December 2019, scanning the sky at an approximately six-month cadence. Here, we present new catalogues of point-like and extended X-ray sources derived from the first three completed eROSITA all-sky surveys (eRASS:3), covering the western Galactic hemisphere, which Germany's eROSITA consortium holds proprietary rights for. We describe the observational strategy, data processing, and analysis pipelines. We also characterise the resulting X-ray source populations. The eRASS:3 main catalogue contains nearly two million sources, including 1,911,744 point-like and 63,796 extended sources, detected in the 0.2-2.3 keV energy band, eROSITA's most sensitive energy window. This volume has doubled the X-ray source content of eRASS1 and provides a comprehensive census of X-ray-emitting objects across diverse astrophysical classes. We also released a secondary hard catalogue of nearly 15,000 sources detected in the harder 2.3-5.0 keV energy band. In addition, we released six catalogues, three for the main sample and three for the hard sample, in which we identify and classify the optical and infrared counterparts of eRASS:3 point-like sources. This approach delivers a homogeneous, high-quality identification of mostly extragalactic X-ray emitters; for example, we estimate that approximately 88% of the 1.4 million counterparts identified within the footprints of the Legacy Survey Imaging for DESI are extragalactic sources. This work has enabled the generation of samples optimised for completeness and purity, while expanding the discovery space for rare populations. The second data release (DR2) of the SRG/eROSITA all-sky survey is a catalogue-only release, comprising the catalogues presented in this work together with an updated version of the eROSITA upper flux limit server.

astro-ph.HE

The SRG/eROSITA all-sky survey: Cosmology constraints from cluster abundances in the western Galactic hemisphere

The cluster mass function traces the growth of linear density perturbations and provides valuable insights into the growth of structures, the nature of dark matter, and the cosmological parameters governing the Universe. The primary science goal of eROSITA, on board the {\it Spectrum Roentgen Gamma (SRG)} mission, launched in 2019, is to constrain cosmology through the evolution of cluster mass function. In this paper, we present the cosmological constraints obtained from 5259 clusters of galaxies detected over an area of 12791~deg$^2$ in the Western Galactic Hemisphere of the eROSITA's first All-Sky Survey (eRASS1). The common footprint region between the eROSITA Survey and DES, KiDS, and HSC surveys is used for calibration of the scaling between X-ray count rate and their total mass through measurements of their weak gravitational lensing signal. eRASS1 cluster abundances constrain the $\Lambda$CDM parameters, which are the energy density of the total matter to $\Omega_{\mathrm{m}}=0.29^{+0.01}_{-0.02}$, and the normalization of the density fluctuations to $\sigma_8=0.88\pm0.02$ and their combination yields $S_8=\sigma_8 (\Omega_\mathrm{m} / 0.3)^{0.5}=0.86\pm0.01$, consistent and at a similar precision with the state-of-the-art CMB measurements. eRASS1 cosmological experiment places a most stringent upper limit on the summed masses of left-handed light neutrinos to $\sum m_\nu< 0.22\mathrm{~eV}$ (95\% confidence interval). Combining eRASS1 cluster abundance measurements with CMB and ground-based neutrino oscillation experiments, we measure the summed neutrino masses to be $\sum m_\nu=0.08_{-0.02}^{+0.03}\mathrm{~eV}$ or $\sum m_\nu=0.12_{-0.01}^{+0.03}\mathrm{~eV}$ depending on the mass hierarchy scenario for neutrino eigenstates. eRASS1 cluster abundances significantly improve the constraints on the dark energy equation of state parameter to $w=-1.12\pm0.12$. (ABRIDGED)

astro-ph.CO

The SRG/eROSITA all-sky survey: First X-ray catalogues and data release of the western Galactic hemisphere

The eROSITA telescope array aboard the Spektrum Roentgen Gamma (SRG) satellite began surveying the sky in December 2019, with the aim of producing all-sky X-ray source lists and sky maps of an unprecedented depth. Here we present catalogues of both point-like and extended sources using the data acquired in the first six months of survey operations (eRASS1; completed June 2020) over the half sky whose proprietary data rights lie with the German eROSITA Consortium. We describe the observation process, the data analysis pipelines, and the characteristics of the X-ray sources. With nearly 930000 entries detected in the most sensitive 0.2-2.3 keV energy range, the eRASS1 main catalogue presented here increases the number of known X-ray sources in the published literature by more than 60%, and provides a comprehensive inventory of all classes of X-ray celestial objects, covering a wide range of physical processes. A smaller catalogue of 5466 sources detected in the less sensitive but harder 2.3-5 keV band is the result of the first true imaging survey of the entire sky above 2 keV. We show that the number counts of X-ray sources in eRASS1 are consistent with those derived over narrower fields by past X-ray surveys of a similar depth, and we explore the number counts variation as a function of the location in the sky. Adopting a uniform all-sky flux limit (at 50% completeness) of F_{0.5-2 keV} > 5 \times 10^{-14}$ erg\,s$^{-1}$\,cm$^{-2}$, we estimate that the eROSITA all-sky survey resolves into individual sources about 20% of the cosmic X-ray background in the 1-2 keV range. The catalogues presented here form part of the first data release (DR1) of the SRG/eROSITA all-sky survey. Beyond the X-ray catalogues, DR1 contains all detected and calibrated event files, source products (light curves and spectra), and all-sky maps. Illustrative examples of these are provided.

astro-ph.HE

Spectral performance of the Microchannel X-ray Telescope on board the SVOM mission

The Microchannel X-ray Telescope (MXT) is an innovative compact X-ray instrument on board the SVOM astronomical mission dedicated to the study of transient phenomena such as gamma-ray bursts. During 3 weeks, we have tested the MXT flight model at the Panter X-ray test facility under the nominal temperature and vacuum conditions that MXT will undergo in-flight. We collected data at series of characteristic energies probing the entire MXT energy range, from 0.28 keV up to 9 keV, for multiple source positions with the center of the point spread function (PSF) inside and outside the detector field of view (FOV). We stacked the data of the positions with the PSF outside the FOV to obtain a uniformly illuminated matrix and reduced all data sets using a dedicated pipeline. We determined the best spectral performance of MXT using an optimized data processing, especially for the energy calibration and the charge sharing effect induced by the pixel low energy thresholding. Our results demonstrate that MXT is compliant with the instrument requirement regarding the energy resolution (<80 eV at 1.5 keV), the low and high energy threshold, and the accuracy of the energy calibration ($\pm$20 eV). We also determined the charge transfer inefficiency (~$10^{-5}$) of the detector and modeled its evolution with energy prior to the irradiation that MXT will undergo during its in-orbit lifetime. Finally, we measured the relation of the energy resolution as function of the photon energy. We determined an equivalent noise charge of 4.9 $\pm$ 0.2 e- rms for the MXT detection chain and a Fano factor of 0.131 $\pm$ 0.003 in silicon at 208 K, in agreement with previous works. This campaign confirmed the promising scientific performance that MXT will be able to deliver during the mission lifetime.

astro-ph.IM

The Scientific Performance of the Microchannel X-ray Telescope on board the SVOM Mission

The Microchannel X-ray Telescope (MXT) will be the first focusing X-ray telescope based on a "Lobster-Eye" optical design to be flown on Sino-French mission SVOM. SVOM will be dedicated to the study of Gamma-Ray Bursts and more generally time-domain astrophysics. The MXT telescope is a compact (focal length ~ 1.15 m) and light (< 42 kg) instrument, sensitive in the 0.2--10 keV energy range. It is composed of an optical system, based on micro-pore optics (MPOs) of 40 micron pore size, coupled to a low-noise pnCDD X-ray detector. In this paper we describe the expected scientific performance of the MXT telescope, based on the End-to-End calibration campaign performed in fall 2021, before the integration of the SVOM payload on the satellite.

astro-ph.IM

The eROSITA X-ray telescope on SRG

eROSITA (extended ROentgen Survey with an Imaging Telescope Array) is the primary instrument on the Spectrum-Roentgen-Gamma (SRG) mission, which was successfully launched on July 13, 2019, from the Baikonour cosmodrome. After the commissioning of the instrument and a subsequent calibration and performance verification phase, eROSITA started a survey of the entire sky on December 13, 2019. By the end of 2023, eight complete scans of the celestial sphere will have been performed, each lasting six months. At the end of this program, the eROSITA all-sky survey in the soft X-ray band (0.2--2.3\,keV) will be about 25 times more sensitive than the ROSAT All-Sky Survey, while in the hard band (2.3--8\,keV) it will provide the first ever true imaging survey of the sky. The eROSITA design driving science is the detection of large samples of galaxy clusters up to redshifts $z>1$ in order to study the large-scale structure of the universe and test cosmological models including Dark Energy. In addition, eROSITA is expected to yield a sample of a few million AGNs, including obscured objects, revolutionizing our view of the evolution of supermassive black holes. The survey will also provide new insights into a wide range of astrophysical phenomena, including X-ray binaries, active stars, and diffuse emission within the Galaxy. Results from early observations, some of which are presented here, confirm that the performance of the instrument is able to fulfil its scientific promise. With this paper, we aim to give a concise description of the instrument, its performance as measured on ground, its operation in space, and also the first results from in-orbit measurements.

astro-ph.HE

The Microchannel X-ray Telescope on Board the SVOM Satellite

We present the Micro-channel X-ray Telescope (MXT), a new narrow-field (about 1°) telescope that will be flying on the Sino-French SVOM mission dedicated to Gamma-Ray Burst science, scheduled for launch in 2021. MXT is based on square micro pore optics (MPOs), coupled with a low noise CCD. The optics are based on a "Lobster Eye" design, while the CCD is a focal plane detector similar to the type developed for the seven eROSITA telescopes. MXT is a compact and light (<35 kg) telescope with a 1 m focal length, and it will provide an effective area of about 45 cmsq on axis at 1 keV. The MXT PSF is expected to be better than 4.2 arc min (FWHM) ensuring a localization accuracy of the afterglows of the SVOM GRBs to better than 1 arc min (90\% c.l. with no systematics) provided MXT data are collected within 5 minutes after the trigger. The MXT sensitivity will be adequate to detect the afterglows for almost all the SVOM GRBs as well as to perform observations of non-GRB astrophysical objects. These performances are fully adapted to the SVOM science goals, and prove that small and light telescopes can be used for future small X-ray missions.

astro-ph.IM

The Microchannel X-ray Telescope for the Gamma-Ray Burst mission SVOM

We present the Microchannel X-ray Telescope, a new light and compact focussing telescope that will be flying on the Sino-French SVOM mission dedicated to Gamma-Ray Burst science. The MXT design is based on the coupling of square pore micro-channel plates with a low noise pnCCD. MXT will provide an effective area of about 50 cmsq, and its point spread function is expected to be better than 3.7 arc min (FWHM) on axis. The estimated sensitivity is adequate to detect all the afterglows of the SVOM GRBs, and to localize them to better then 60 arc sec after five minutes of observation.

astro-ph.IM

The Hot and Energetic Universe: The Wide Field Imager (WFI) for Athena+

The Wide Field Imager (WFI) is one of the two scientific instruments proposed for the Athena+ X-ray observatory. It will provide imaging in the 0.1-15 keV band over a wide field, simultaneously with spectrally and time-resolved photon counting. The instrument is designed to make optimal use of the grasp (collecting area times solid angle product) provided by the optical design of the Athena+ mirror system (Willingale et al. 2013), by combining a sensitive approx. 40' diameter field of view (baseline; 50' goal) DEPFET detector with a pixel size properly sampling the angular resolution of 5 arc sec on-axis (half energy width).This synthesis makes the WFI a very powerful survey instrument, significantly surpassing currently existing capabilities (Nandra et al. 2013; Aird et al. 2013). In addition, the WFI will provide unprecedented simultaneous high-time resolution and high count rate capabilities for the observation of bright sources with low pile-up and high efficiency. In this paper, we summarize the instrument design, the status of the technology development, and the baseline performance.

astro-ph.IM

eROSITA Science Book: Mapping the Structure of the Energetic Universe

eROSITA is the primary instrument on the Russian SRG mission. In the first four years of scientific operation after its launch, foreseen for 2014, it will perform a deep survey of the entire X-ray sky. In the soft X-ray band (0.5-2 keV), this will be about 20 times more sensitive than the ROSAT all sky survey, while in the hard band (2-10 keV) it will provide the first ever true imaging survey of the sky at those energies. Such a sensitive all-sky survey will revolutionize our view of the high-energy sky, and calls for major efforts in synergic, multi-wavelength wide area surveys in order to fully exploit the scientific potential of the X-ray data. The design-driving science of eROSITA is the detection of very large samples (~10^5 objects) of galaxy clusters out to redshifts z>1, in order to study the large scale structure in the Universe, test and characterize cosmological models including Dark Energy. eROSITA is also expected to yield a sample of around 3 millions Active Galactic Nuclei, including both obscured and un-obscured objects, providing a unique view of the evolution of supermassive black holes within the emerging cosmic structure. The survey will also provide new insights into a wide range of astrophysical phenomena, including accreting binaries, active stars and diffuse emission within the Galaxy, as well as solar system bodies that emit X-rays via the charge exchange process. Finally, such a deep imaging survey at high spectral resolution, with its scanning strategy sensitive to a range of variability timescales from tens of seconds to years, will undoubtedly open up a vast discovery space for the study of rare, unpredicted, or unpredictable high-energy astrophysical phenomena. In this living document we present a comprehensive description of the main scientific goals of the mission, with strong emphasis on the early survey phases.

astro-ph.HE

Accelerator experiments with soft protons and hyper-velocity dust particles: application to ongoing projects of future X-ray missions

We report on our activities, currently in progress, aimed at performing accelerator experiments with soft protons and hyper-velocity dust particles. They include tests of different types of X-ray detectors and related components (such as filters) and measurements of scattering of soft protons and hyper-velocity dust particles off X-ray mirror shells. These activities have been identified as a goal in the context of a number of ongoing space projects in order to assess the risk posed by environmental radiation and dust and qualify the adopted instrumentation with respect to possible damage or performance degradation. In this paper we focus on tests for the Silicon Drift Detectors (SDDs) used aboard the LOFT space mission. We use the Van de Graaff accelerators at the University of Tübingen and at the Max Planck Institute for Nuclear Physics (MPIK) in Heidelberg, for soft proton and hyper-velocity dust tests respectively. We present the experimental set-up adopted to perform the tests, status of the activities and some very preliminary results achieved at present time.

astro-ph.IM

eROSITA on SRG: a X-ray all-sky survey mission

eROSITA (extended ROentgen Survey with an Imaging Telescope Array) is the core instrument on the Russian Spektrum-Roentgen-Gamma (SRG) mission which is scheduled for launch in late 2012. eROSITA is fully approved and funded by the German Space Agency DLR and the Max-Planck-Society. The design driving science is the detection of 50 - 100 thousands Clusters of Galaxies up to redshift z ~ 1.3 in order to study the large scale structure in the Universe and test cosmological models, especially Dark Energy. This will be accomplished by an all-sky survey lasting for four years plus a phase of pointed observations. eROSITA consists of seven Wolter-I telescope modules, each equipped with 54 Wolter-I shells having an outer diameter of 360 mm. This would provide and effective area at 1.5 keV of ~ 1500 cm2 and an on axis PSF HEW of 15" which would provide an effective angular resolution of 25"-30". In the focus of each mirror module, a fast frame-store pn-CCD will provide a field of view of 1 deg in diameter for an active FOV of ~ 0.83 deg^2. At the time of writing the instrument development is currently in phase C/D.

astro-ph.IM

CTI history of the EPIC pn camera

The pn camera of EPIC is inherently robust against radiation damage effects. Nevertheless, the knowledge of charge transfer inefficiency (CTI) of the pn camera is crucial for obtaining the correct energy scale. We describe detailed in-orbit monitoring of this effect, utilizing the internal calibration source. We find that during the first two years in orbit the CTI increased by about 4% for Al-K and by about 7% for Mn-K. The increases in the CTI are well within expectations, with no measurable effect on the energy resolution.

astro-ph

The first broad-band X-ray images and spectra of the 30 Doradus region in the LMC

We present the XMM-Newton first light image, taken in January 2000 with the EPIC pn camera during the instrument's commissioning phase, when XMM-Newton was pointing towards the Large Magellanic Cloud (LMC). The field is rich in different kinds of X-ray sources: point sources, supernova remnants (SNRs) and diffuse X-ray emission from LMC interstellar gas. The observations are of unprecedented sensitivity, reaching a few 10^32 erg/s for point sources in the LMC. We describe how these data sets were analysed and discuss some of the spectroscopic results. For the SNR N157B the power law spectrum is clearly steeper than previously determined from ROSAT and ASCA data. The existence of a significant thermal component is evident and suggests that N157B is not a Crab-like but a composite SNR. Most puzzling is the spectrum of the LMC hot interstellar medium, which indicates a significant overabundance of Ne and Mg of a few times solar.

astro-ph