SearcharxivSearch

arXiv subjects

N. Mirabolfathi

Publications and source records attributed to N. Mirabolfathi.

At least 19 recordsLinked to original sources

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

physics.ins-det

Exploring Low Energy Excess in MINER with sapphire detectors using Convolutional Variational Autoencoder (CVAE)

As cryogenic detectors push toward ever-lower energy thresholds, their sensitivity is increasingly constrained by a persistent low-energy background known as the low-energy excess (LEE). We report observation of LEE in the MINER experiment using a sapphire ($\mathrm{Al_2O_3}$) detector at energies around 200 eV, with the excess reproducibly reappearing after each non-operational warm-up period. To address this limiting background, we implement an unsupervised convolutional variational autoencoder (CVAE) framework that identifies anomalous events through a reconstruction-based anomaly score. For the first time in a pulse-shape driven analysis, we uncover a significant deviation in the rise-time of LEE events relative to Monte Carlo simulated ideal signals. Using this feature, we develop a discrimination pipeline based on rise-time selection. This method achieves up to 53\% rejection of LEE events, corresponding to an expected sensitivity improvement of nearly 10\% for MINER at HFIR. These findings are consistent with a scenario in which a substantial fraction of the LEE originates from bulk-related defects or microfractures within the detector crystal, while leaving room for additional detector-related contributions. Our result provides a powerful, data-driven pathway for mitigating LEE and enhancing the discovery potential of next-generation cryogenic experiments.

physics.ins-det

CE$\nu$NS Search with Cryogenic Sapphire Detectors at MINER: Results from the TRIGA reactor data and Future Sensitivity at HFIR

We report on a search for coherent elastic neutrino--nucleus scattering (CE$\nu$NS) using cryogenic sapphire (Al$_2$O$_3$) detectors deployed at the Mitchell Institute Neutrino Experiment at Reactor (MINER), located near the 1~MW$_\text{th}$ TRIGA research reactor at Texas A\&M University. The experiment operated with a primary detector mass of 72~g and achieved a baseline energy resolution of $\sim 40$~eV. Using exposures of 158~g-days (reactor-on) and 381~g-days (reactor-off), we performed a statistical background subtraction in the energy region of 0.25--3~keV. A GEANT4 simulation has been performed to understand the reactor-correlated background present in the data and it agrees with our observations. The resulting best-fit ratio of the observed CE$\nu$NS rate to the Standard Model prediction after rejecting the reactor induced background from the data with the help of simulation, is $\rho = 0.26\pm 1534.74~\mathrm{(stat)} \pm 0.05~\mathrm{(sys)}$ with a significance of $0.007 \pm 0.022~\mathrm{(stat)} \pm 0.001~\mathrm{(sys)}$. This low significance indicates a high background rate at low energies. To have enhanced sensitivity, the MINER collaboration plans to relocate the experiment to the 85~MW$_\text{th}$ High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). With improved shielding, increased detector mass, and higher antineutrino flux, the upgraded setup is projected to achieve a 3$\sigma$ CE$\nu$NS detection within 30~kg$\cdot$days of exposure.

nucl-ex

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

hep-ex

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

physics.ins-det

Low-Energy Calibration of SuperCDMS HVeV Cryogenic Silicon Calorimeters Using Compton Steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. We demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution (HVeV) detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

physics.ins-det

MINER Reactor Based Search for Axion-Like Particles Using Sapphire (Al2O3) Detectors

The absence of definitive results for WIMP dark matter has sparked growing interest in alternative dark matter candidates, such as axions and Axion-Like Particles (ALPs), which also provide insight into the strong CP problem. The Mitchell Institute Neutrino Experiment at Reactor (MINER), conducted at the Nuclear Science Center of Texas A&M University, investigated ALPs near a 1 MW TRIGA nuclear reactor core, positioned approximately 4 meters away. This experiment employed cryogenic sapphire detectors with a low detection threshold (approximately 100 eV), equipped with a Transition Edge Sensor capable of detecting athermal phonons. Due to the low-background environment, we were able to exclude ALPs with axion-photon coupling and axion-electron coupling as small as \(g_{a\gamma\gamma} = 10^{-5}\) and \(g_{aee} = 10^{-7}\), respectively. Energy depositions below 3 keV were not considered and remain blinded for our Coherent Elastic Neutrino Nucleus Scattering (CEvNS) analysis. This is the first result demonstrating the MINER experiment's potential to probe low-mass ALPs, enabled by its low-threshold detector and proximity to a reactor.

hep-ex

Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection

This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.

hep-ex

Improved Modelling of Detector Response Effects in Phonon-based Crystal Detectors used for Dark Matter Searches

Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number of electron-hole pairs created by the interaction. However, crystal impurities and surface effects can cause propagating charges to either become trapped inside the crystal or create additional unpaired charges, producing non-quantized measured energy as a result. A new analytical model for describing these detector response effects in phonon-based crystal detectors is presented. This model improves upon previous versions by demonstrating how the detector response, and thus the measured energy spectrum, is expected to differ depending on the source of events. We use this model to extract detector response parameters for SuperCDMS HVeV detectors, and illustrate how this robust modelling can help statistically discriminate between sources of events in order to improve the sensitivity of dark matter search experiments.

physics.ins-det

First measurement of the nuclear-recoil ionization yield in silicon at 100 eV

We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.

physics.ins-det

A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS

We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search provides overall considerably more stringent limits and excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.

hep-ex

A portable and high intensity 24 keV neutron source based on $^{124}$Sb-$^{9}$Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the $^{124}$Sb-$^9$Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from $^{124}$Sb decays while letting through the neutrons. To increase the $^{124}$Sb activity and thus the neutron flux, a $>$1 GBq $^{124}$Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20-25 keV to be 5.36$\pm$0.20 neutrons per cm$^2$ per second and the total gamma flux to be 213$\pm$6 gammas per cm$^2$ per second (numbers scaled to 1 GBq activity of the $^{124}$Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

physics.ins-det

Development of a large-mass, low-threshold detector system with simultaneous measurements of athermal phonons and scintillation light

We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to the difference in their scintillation light yield. While such systems with simultaneous phonon and light detection have been demonstrated earlier with smaller detectors, our system is designed to provide a large detector mass with high amplification for the limited scintillation light. Future work will focus on at least an order of magnitude improvement in the light collection efficiency by having a highly reflective detector housing and custom phonon mask design to maximize light collection by the silicon high-voltage detector.

physics.ins-det

Effective Field Theory Analysis of CDMSlite Run 2 Data

CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$\sigma$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.

astro-ph.CO

Investigating the sources of low-energy events in a SuperCDMS-HVeV detector

Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.

hep-ex

Large-mass, low-threshold sapphire detector for rare event searches

Low mass nuclear recoil dark matter and coherent-elastic-neutrino-nucleus-scattering (CENNS) searches confront similar challenges in choosing ultra-low threshold and large-mass detectors. We report experimental results from the first-of-its-kind 100 g single-crystal sapphire detector design with a diameter of 76 mm and thickness of 4 mm. The detector is designed to be sensitive for low-energy rare interactions with an intention to investigate the low mass region of dark matter phase-space and search for CENNS at the reactor site. Sapphire is a crystal of aluminum oxide (Al2O3) and has been found to be a good candidate for light mass spin-dependent dark matter search experiments due to its lower atomic mass compared to other detector materials such as germanium and silicon. Using the data collected from the test facility at Texas A&M University, we were able to resolve low energy lines from calibration sources and estimated that our newly developed sapphire detector has a baseline recoil energy resolution of 18 eV. These detectors are operated at 0 V with the phonon-assisted detection providing a quenching-free low-threshold operation.

physics.ins-det

A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility

The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion. The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.

physics.ins-det

A novel active veto prototype detector with an inner target for improved rare event searches

We report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass $\sim$500 g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced. A 25 mm diameter germanium inner target detector of mass $\sim$10 g was mounted inside the veto detector. The detector was designed using inputs from a GEANT4 based simulation, where it was modeled to be sandwiched between two germanium detectors. The simulation showed that the background rates (dominantly gamma interactions) could be reduced by $>$ 90$\%$, and that such an arrangement is sufficient for aggressive background reduction needed for neutrino and dark matter search experiments. During testing at the experimental site the veto detector prototype achieved a baseline resolution of 1.24 $\pm$ 0.02 keV while hosting a functional inner target detector. The baseline resolution of the inner target detector was 147 $\pm$ 2 eV. The detectors were operated at mK temperatures. The experimental results of an identical detector arrangement are in excellent agreement with the simulation.

physics.ins-det