SearcharxivSearch

arXiv subjects

N. Moggi

Publications and source records attributed to N. Moggi.

At least 19 recordsLinked to original sources

Measurement of muon (anti-)neutrino charged-current quasielastic-like cross section using off-axis NuMI beam at ICARUS

This paper presents the first neutrino cross-section measurement from the ICARUS detector at Fermilab, using NuMI (Neutrinos at the Main Injector) beam data collected from two beam operation periods corresponding to $2.5\times10^{20}$ protons-on-target in neutrino beam mode. The signal is defined by events with no pions produced in the final state, a topology dominated by charged-current quasielastic-like (CCQE-like) signatures. The measurement is reported as flux-averaged differential cross sections as functions of kinematic variables that provide sensitivity to the complex nuclear effects which often dominate the systematic uncertainty budgets of neutrino oscillation measurements. Specifically, this work reports cross sections in two angular variables -- the angle of the outgoing lepton and the opening angle between the lepton and leading proton -- and two variables characterizing the kinematic imbalance between the muon and proton in the plane transverse to the incoming neutrino. These results are compared against predictions from a variety of neutrino event generators, with $p$-values calculated between the extracted cross sections and each prediction. Overall, the predictions agree with the data; however, the current budget of uncertainties does not yet provide sufficient discriminating power to favor a specific model.

hep-ex

Operation of the Trigger System for the ICARUS Detector at Fermilab

The ICARUS liquid argon TPC detector is taking data on the Booster (BNB) and Main Injector (NuMI) Neutrino beam lines at Fermilab with a trigger system based on the scintillation light produced by charged particles in coincidence with the proton beam extraction from the accelerators. The architecture and the deployment of the trigger system in the first two runs for physics are presented, as well as the triggered event rates. The event recognition efficiency has been evaluated as a function of the deposited energy and the position of cosmic muons stopping inside the detector.

hep-ex

Design and Implementation of the Cosmic Ray Tagger System for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system ($\sim$1100 m$^2$), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

hep-ex

Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber

This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination on the angle of the ionizing particle track relative to the drift electric field is observed. An ellipsoid modified box (EMB) model of recombination describes the data across all measured angles. These measurements are used for the calorimetric energy scale calibration of the ICARUS TPC, which is also presented. The impact of the EMB model is studied on calorimetric particle identification, as well as muon and proton energy measurements. Accounting for the angular dependence in EMB recombination improves the accuracy and precision of these measurements.

physics.ins-det

Calibration and simulation of ionization signal and electronics noise in the ICARUS liquid argon time projection chamber

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedure removes non-uniformities in the ICARUS TPC response to charge in space and time. This work leverages the copious number of cosmic ray muons available to ICARUS at the surface. The ionization signal shape simulation applies a novel procedure that tunes the simulation to match what is measured in data. The end result of the equalization procedure and simulation tuning allows for a comparison of charge measurements in ICARUS between Monte Carlo simulation and data, showing good performance with minimal residual bias between the two.

hep-ex

Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE

The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta ($0 νββ$) decay. Here we show results from the search for $0 νββ$ decay of $^{130}$Te, using the latest advanced cryogenic calorimeters with the CUORE experiment. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultra-low temperatures, operational longevity, and the low levels of ionising radiation emanating from the cryogenic infrastructure. We find no evidence for $0 νββ$ decay and set a lower bound of $T_{1/2}^{0 ν} > 2.2 \times 10^{25}$ years at a 90% credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultra-low temperature cryogenic environment.

nucl-ex

Coded masks for imaging of neutrino events

The capture of scintillation light emitted by liquid Argon and Xenon under molecular excitations by charged particles is still a challenging task. Here we present a first attempt to design a device able to grab sufficiently high luminosity in order to reconstruct the path of ionizing particles. This preliminary study is based on the use of masks to encode the light signal combined with single-photon detectors. In this respect, the proposed system is able to detect tracks over focal distances of about tens of centimeters. From numerical simulations it emerges that it is possible to successfully decode and recognize signals, even complex, with a relatively limited number of acquisition channels. Such innovative technique can be very fruitful in a new generation of detectors devoted to neutrino physics and dark matter search. Indeed the introduction of coded masks combined with SiPM detectors is proposed for a liquid-Argon target in the Near Detector of the DUNE experiment.

physics.ins-det

Search for Double-Beta Decay of $\mathrm{^{130}Te}$ to the $0^+$ States of $\mathrm{^{130}Xe}$ with CUORE

The CUORE experiment is a large bolometric array searching for the lepton number violating neutrino-less double beta decay ($0νββ$) in the isotope $\mathrm{^{130}Te}$. In this work we present the latest results on two searches for the double beta decay (DBD) of $\mathrm{^{130}Te}$ to the first $0^{+}_2$ excited state of $\mathrm{^{130}Xe}$: the $0νββ$ decay and the Standard Model-allowed two-neutrinos double beta decay ($2νββ$). Both searches are based on a 372.5 kg$\times$yr TeO$_2$ exposure. The de-excitation gamma rays emitted by the excited Xe nucleus in the final state yield a unique signature, which can be searched for with low background by studying coincident events in two or more bolometers. The closely packed arrangement of the CUORE crystals constitutes a significant advantage in this regard. The median limit setting sensitivities at 90\% Credible Interval (C.I.) of the given searches were estimated as $\mathrm{S^{0ν}_{1/2} = 5.6 \times 10^{24} \: \mathrm{yr}}$ for the ${0νββ}$ decay and $\mathrm{S^{2ν}_{1/2} = 2.1 \times 10^{24} \: \mathrm{yr}}$ for the ${2νββ}$ decay. No significant evidence for either of the decay modes was observed and a Bayesian lower bound at $90\%$ C.I. on the decay half lives is obtained as: $\mathrm{(T_{1/2})^{0ν}_{0^+_2} > 5.9 \times 10^{24} \: \mathrm{yr}}$ for the $0νββ$ mode and $\mathrm{(T_{1/2})^{2ν}_{0^+_2} > 1.3 \times 10^{24} \: \mathrm{yr}}$ for the $2νββ$ mode. These represent the most stringent limits on the DBD of $^{130}$Te to excited states and improve by a factor $\sim5$ the previous results on this process.

nucl-ex

Measurement of the 2$νββ$ Decay Half-life of $^{130}$Te with CUORE

We measured two-neutrino double beta decay of $^{130}$Te using an exposure of 300.7 kg$\cdot$yr accumulated with the CUORE detector. Using a Bayesian analysis to fit simulated spectra to experimental data, it was possible to disentangle all the major background sources and precisely measure the two-neutrino contribution. The half-life is in agreement with past measurements with a strongly reduced uncertainty: $T^{2ν}_{1/2} = 7.71^{+0.08}_{-0.06}\mathrm{(stat.)}^{+0.12}_{-0.15}\mathrm{(syst.)}\times10^{20}$ yr. This measurement is the most precise determination of the $^{130}$Te 2$νββ$ decay half-life to date.

nucl-ex

New results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its 2\textsuperscript{nd} result of the search for $0νββ$ with a TeO$_2$ exposure of 372.5 kg$\cdot$yr and a median exclusion sensitivity to a $^{130}$Te $0νββ$ decay half-life of $1.7\cdot 10^{25}$ yr. We find no evidence for $0νββ$ decay and set a 90\% C.I. (credibility interval) Bayesian lower limit of $3.2\cdot 10^{25}$ yr on the $^{130}$Te $0νββ$ decay half-life. In this work, we present the current status of CUORE's search for $0νββ$, as well as review the detector performance. Finally, we give an update of the CUORE background model and the measurement of the $^{130}$Te two neutrino double-beta ($2νββ$) decay half-life.

physics.ins-det

Improved Limit on Neutrinoless Double-Beta Decay in $^{130}$Te with CUORE

We report new results from the search for neutrinoless double-beta decay in $^{130}$Te with the CUORE detector. This search benefits from a four-fold increase in exposure, lower trigger thresholds and analysis improvements relative to our previous results. We observe a background of $(1.38\pm0.07)\cdot10^{-2}$ counts$/($keV$\cdot$kg$\cdot$yr$)$ in the $0νββ$ decay region of interest and, with a total exposure of 372.5 kg$\cdot$yr, we attain a median exclusion sensitivity of $1.7\cdot10^{25}$ yr. We find no evidence for $0νββ$ decay and set a $90\%$ CI Bayesian lower limit of $3.2\cdot10^{25}$ yr on the $^{130}$Te half-life for this process. In the hypothesis that $0νββ$ decay is mediated by light Majorana neutrinos, this results in an upper limit on the effective Majorana mass of 75-350 meV, depending on the nuclear matrix elements used.

nucl-ex

Results of CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) at the Laboratori Nazionali del Gran Sasso, Italy, is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently in data taking, searching for the neutrinoless double beta decay of 130 Te. CUORE is operational since the spring of 2017. The initial science run already allowed to provide the most stringent limit on the neutrinoless double beta decay half-life of 130Te, and to perform the most precise measurement of the two-neutrino double beta decay half-life. Up to date, we have more than doubled the collected exposure. In this talk, we presenteded the most recent results and discuss the present status of the CUORE experiment.

nucl-ex

Double-beta decay of ${}^{130}$Te to the first $0^+$ excited state of ${}^{130}$Xe with CUORE-0

We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the half-lives: $τ^{0ν}_{0^+}>7.9\cdot 10^{23}$ yr and $τ^{2ν}_{0^+}>2.4\cdot 10^{23}$ yr. Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: $τ^{0ν}_{0^+}>1.4\cdot 10^{24}$ yr and $τ^{2ν}_{0^+}>2.5\cdot 10^{23}$ yr.

nucl-ex

Update on the recent progress of the CUORE experiment

CUORE is a 741 kg array of 988 TeO$_2$ bolometeric crystals designed to search for the neutrinoless double beta decay of $^{130}$Te and other rare processes. CUORE has been taking data since summer 2017, and as of summer 2018 collected a total of 86.3 kg$\cdot$yr of TeO$_2$ exposure. Based on this exposure, we were able to set a limit on the $0νββ$ half-life of $^{130}$Te of $T^{0ν}_{1/2}>1.5\times10^{25}$ yr at 90% C.L. At this conference, we showed the decomposition of the CUORE background and were able to extract a $^{130}$Te $2νββ$ half-life of $T_{1/2}^{2ν}=[7.9\pm0.1 \mathrm{(stat.)}\pm0.2 \mathrm{(syst.)}]\times10^{20}$ yr. This is the most precise measurement of this half-life and is consistent with previous measurements.

nucl-ex

First Results from CUORE: A Search for Lepton Number Violation via $0νββ$ Decay of $^{130}$Te

The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we find no evidence for neutrinoless double-beta decay. The median statistical sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic uncertainties, we place a lower limit on the decay half-life of $T^{0ν}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find $T^{0ν}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find $m_{ββ}<(110 - 520)$ meV, where the range reflects the nuclear matrix element estimates employed.

nucl-ex

Study of Rare Nuclear Processes with CUORE

TeO2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0ν} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment looking for neutrinoless double beta decay, it is not the only study that CUORE will contribute to in the field of nuclear and particle physics. As already done over the years with many small-scale experiments, CUORE will investigate both rare decays (such as the two-neutrino double beta decay of 130-Te and the hypothesized electron capture in 123-Te), and rare processes (e.g., dark matter and axion interactions). This paper describes some of the achievements of past experiments that used TeO2 bolometers, and perspectives for CUORE.

nucl-ex

Low Energy Analysis Techniques for CUORE

CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils in CUORE-0.

physics.ins-det

Search for Neutrinoless $β^{+}\hspace{-0.2em}EC$ Decay of $^{120}$Te with CUORE-0

We have performed a search for neutrinoless $β^{+}\hspace{-0.2em}EC$ decay of $^{120}$Te using the final CUORE-0 data release. We describe a new analysis method for the simultaneous fit of signatures with different event topology, and of data subsets with different signal efficiency, obtaining a limit on the half-life of the decay of $T_{1/2}>1.6\cdot10^{21}$ yr at $90\%$ CI. Combining this with results from Cuoricino, a predecessor experiment, we obtain the strongest limit to date, corresponding to $T_{1/2}>2.7\cdot10^{21}$ yr at $90\%$ CI.

nucl-ex