SearcharxivSearch

arXiv subjects

N. Osborne

Publications and source records attributed to N. Osborne.

6 recordsLinked to original sources

Ion Temperature Measurements in the MAST-U Divertor During Steady State Plasmas and ELM Burn Through Phenomena

This study presents ion temperature (\(T_i\)) measurements in the MAST-U divertor, using a Retarding Field Energy Analyzer (RFEA). Steady state measurements were made during an L-Mode plasma with the strike point on the RFEA. ELM measurements were made with the strike point swept over the RFEA. The scenarios are characterized by a plasma current (\(I_p\)) of 750 kA, line average electron density (\(n_e\)) between \(1.6 \times 10^{19}\) and \(4.5 \times 10^{19}\,\text{m}^{-3}\), and Neutral Beam Injection (NBI) power ranging from 1.1 MW to 1.6 MW. The ion temperatures, peaking at approximately 10 eV in steady state, were compared with electron temperatures (\(T_e\)) obtained from Langmuir probes (LP) at the same radial positions. Preliminary findings reveal a \(T_i/T_e\) ratio in the divertor region less than 1 for shot 48008. High temporal resolution measurements captured the dynamics of Edge Localized Modes (ELMs) Burn Through, providing \(T_i\) data as a radial distance from the probe peaking around 20 eV.

physics.plasm-ph

A novel understanding of the role of plasma-molecular kinetics on divertor power exhaust

During detachment, a buffer of neutral atoms and molecules builds up between the target and the ionising plasma. Collisions between the plasma and the molecules play an important role in the detachment process. Studies of plasma-molecular kinetics indicate that the gas temperature is increased during detachment for a wide range of conditions on the MAST-U and TCV tokamaks. This is related to an increased $\mathrm{D}_2$ lifetime during detachment, leading to more plasma-molecule collisions that raise the molecular temperature. Such collisions subsequently result in significant power and momentum losses to the divertor plasma during detachment. Using a simplified inference, these losses are estimated using the rotational temperature, neutral pressure and ionisation front position. Significant power losses (about $10\%$ of $P_{SOL}$) and dominant momentum losses (majority of the upstream pressure) from plasma-molecule collisions are inferred experimentally in long-legged, strongly baffled, detached divertors (MAST-U Super-X divertor), consistent with SOLPS-ITER simulations. The vibrational distribution obtained is compared to a collisional-radiative model setup using the same rate data as SOLPS-ITER, indicating some qualitative agreements and disagreements, potentially highlighting model gaps with regard to the default rates used. These interpretations highlight the importance of plasma-molecular collisions, leading to power and momentum losses during detachment. Our analysis and reduced modelling of these processes provide further insights into detachment control observations, the workings of long-legged divertors and divertor power balance.

physics.plasm-ph

First Ion Temperature Measurements in the MAST-U Divertor via Retarding Field Energy Analyzer

This study presents the first ion temperature (\(T_i\)) measurements from the MAST-U divertor using a Retarding Field Energy Analyzer (RFEA). Embedded within the flat tile of the closed divertor chamber, the RFEA captures \(T_i\) profiles across various plasma scenarios, including transitions to the Super-X configuration. Measurements were conducted under steady-state and transient plasma conditions characterized by a plasma current (\(I_p\)) of 750 kA, electron density (\(n_e\)) between \(2.2 \times 10^{19}\) and \(4.45 \times 10^{19}\,\text{m}^{-3}\), and Neutral Beam Injection (NBI) power ranging from 3.0 MW to 3.2 MW. The ion temperatures, peaking at approximately 17 eV in steady state, were compared with electron temperatures (\(T_e\)) obtained from Langmuir probes (LP) at identical radial positions. The study also examined ion saturation current density (\(J_{\text{sat}}\)) signals to using methodologies similar to previous MAST experiments. Preliminary findings reveal a \(T_i/T_e\) ratio ranging from 1 to 2.2. Additionally, high temporal resolution measurements (100 $\mu s$) captured the dynamics of Edge Localized Modes (ELMs), showing \(T_i\) peaks at 16.03 +- 1.84 eV during ELM events, nearly three times higher than inter-ELM temperatures.

physics.plasm-ph

Investigations of atomic \& molecular processes of NBI-heated discharges in the MAST Upgrade Super-X divertor with implications for reactors

This experimental study presents an in-depth investigation of the performance of the MAST-U Super-X divertor during NBI-heated operation (up to 2.5 MW) focussing on volumetric ion sources and sinks as well as power losses during detachment. The particle balance and power loss analysis revealed the crucial role of Molecular Activated Recombination and Dissociation (MAR and MAD) ion sinks in divertor particle and power balance, which remain pronounced in the change from ohmic to higher power (NBI heated) L-mode conditions. The importance of MAR and MAD remains with double the absorbed NBI heating. MAD results in significant power dissipation (up to $\sim 20 \%$ of $P_{SOL}$), mostly in the cold ($T_e < 5$ eV) detached region. Theoretical and experimental evidence is found for the potential contribution of $D^-$ to MAR and MAD, which warrants further study. These results suggest that MAR and MAD can be relevant in higher power conditions than the ohmic conditions studied previously. Post-processing reactor-scale simulations shows that MAR and MAD can play a significant role in divertor physics and synthetic diagnostic signals of reactor-scale devices, which are currently underestimated in exhaust simulations. This raises implications for the accuracy of reactor-scale divertor simulations of particularly tightly baffled (alternative) divertor configurations.

physics.plasm-ph

Divertor shaping with neutral baffling as a solution to the tokamak power exhaust challenge

Exhausting power from the hot fusion core to the plasma-facing components is one of the biggest challenges in fusion energy. The MAST Upgrade tokamak uniquely integrates strong containment of neutrals within the exhaust area (divertor) with extreme divertor shaping capability. By systematically altering the divertor shape, this study shows the strongest evidence to date that long-legged divertors with a high magnetic field gradient (total flux expansion) deliver key power exhaust benefits without adversely impacting the hot fusion core. These benefits are already achieved with relatively modest geometry adjustments that are more feasible to integrate in reactor designs. Benefits include reduced target heat loads and improved access to, and stability of, a neutral gas buffer that 'shields' the target and enhances power exhaust (detachment). Analysis and model comparisons shows these benefits are obtained by combining multiple shaping aspects: long-legged divertors have expanded plasma-neutral interaction volume that drive reductions in particle and power loads, while total flux expansion enhances detachment access and stability. Containing the neutrals in the exhaust area with physical structures further augments these shaping benefits. These results demonstrate strategic variation in the divertor geometry and magnetic topology is a potential solution to one of fusion's biggest challenges: power exhaust.

physics.plasm-ph

Initial Fulcher band observations from high resolution spectroscopy in the MAST-U divertor

High resolution Fulcher band spectroscopy was used in the MAST-U divertors during Super-X and elongated conventional divertor density ramps with $\text{D}_{2}$ fuelling from the mid-plane high-field side. In the Super-X case (density ramp from Greenwald fraction 0.12 to 0.24), the upper divertor showed ground state rotational temperatures of the $\text{D}_{2}$ molecules increasing from $\sim$6000 K, starting at the detachment onset, to $\sim$9000 K during deepening detachment. This was correlated with the movement of the Fulcher emission region, which is correlated with the ionisation source. The increase in rotational temperature did not occur near the divertor entrance, where the plasma was still ionising. Qualitative agreement was obtained between the lower and upper divertor. Similar rotational temperatures were obtained in the elongated divertor before the detachment onset, although the increase in rotational temperature during detachment was less clearly observed as less deep detachment was obtained. %In the elongated conventional divertor there was some qualitative agreement of this effect impeded by low signal. The measured vibrational distribution of the upper Fulcher state (first four bands) does not agree with a ground state Boltzmann distribution but shows a different characteristic with an elevated population especially in the $\nu = 2$ and $\nu = 3$ bands. The populations of the $\nu = 2$ and $\nu = 3$ band relative to the $\nu = 0$ band are roughly proportional to the $\textit{rotational}$ temperature.

physics.plasm-ph