SearcharxivSearch

arXiv subjects

N. Redaelli

Publications and source records attributed to N. Redaelli.

8 recordsLinked to original sources

The CMS Barrel Timing Layer: test beam confirmation of module timing performance

First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of $2\times10^{14}$ 1 MeV $n_{eq}/cm^2$). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum ionizing particles in the range between 30-60 ps throughout the entire operation at the High Luminosity LHC. A thorough optimization of its components has led to the final detector module layout which exploits 25 $\rm \mu m$ cell size SiPMs and 3.75 mm thick crystals. This design achieved the target performance in a series of test beam campaigns. In this paper we present test beam results which demonstrate the desired performance of detector modules in terms of radiation tolerance, time resolution and response uniformity.

physics.ins-det

Optimization of LYSO crystals and SiPM parameters for the CMS MIP timing detector

For the High-Luminosity (HL-LHC) phase, the upgrade of the Compact Muon Solenoid (CMS) experiment at CERN will include a novel MIP Timing Detector (MTD). The central part of MTD, the barrel timing layer (BTL), is designed to provide a measurement of the time of arrival of charged particles with a precision of 30 ps at the beginning of HL-LHC, progressively degrading to 60 ps while operating in an extremely harsh radiation environment for over a decade. In this paper we present a comparative analysis of the time resolution of BTL module prototypes made of LYSO:Ce crystal bars read out by silicon photo-multipliers (SiPMs). The timing performance measured in beam test campaigns is presented for prototypes with different construction and operation parameters, such as different SiPM cell sizes (15, 20, 25 and 30 $\rm \mu m$), SiPM manufacturers and crystal bar thicknesses. The evolution of time resolution as a function of the irradiation level has been studied using non-irradiated SiPMs as well as SiPMs exposed up to $2\times 10^{14}~n_{eq}/cm^2$ fluence. The key parameters defining the module time resolution such as SiPM characteristics (gain, photon detection efficiency, radiation induced dark count rate) and crystal properties (light output and dimensions) are discussed. These results have informed the final choice of the MTD barrel sensor configuration and offer a unique starting point for the design of future large-area scintillator-based timing detectors in either low or high radiation environments.

physics.ins-det

TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector

The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.

physics.ins-det

Effective exploitation of a geyser bubble-chamber equipment as a background-free fast neutron detector

MOSCAB equipment, a geyser-concept bubble-chamber originally thought for the search of dark matter in the form of WIMPs, is employed for the detection of fast neutrons. Once the background-free operating conditions are determined such that the detector is sensitive only to neutrons, which occurs when the neutron energy threshold required for nucleation is higher than approximately 2.5 MeV, the detector response to fast neutrons is investigated using an AmBe neutron source. Sets of detection efficiency functions are then produced via Monte Carlo simulations and post-processing, their validation being performed experimentally and discussed. Finally, the use of the detector to measure the fast neutron activity of very weak n-sources in clean environments, as well as to monitor the cosmic ray variations through the neutron component of the Extensive Air Showers, is considered.

physics.ins-det

MOSCAB: A geyser-concept bubble chamber to be used in a dark matter search

The MOSCAB experiment (Materia OSCura A Bolle) uses the "geyser technique", a variant of the superheated liquid technique of extreme simplicity. Operating principles of the new dark matter detector and technical solutions of the device are reported in detail. First results obtained in a series of test runs taken in laboratory demonstrate that we have successfully built and tested a geyser-concept bubble chamber that can be used in particle physics, especially in dark matter searches, and that we are ready to move underground for extensive data taking.

physics.ins-det

A new technique for direct investigation of dark matter

The MOSCAB experiment (Materia OSCura A Bolle) uses a new technique for Dark Matter search. The Geyser technique is applied to the construction of a prototype detector with a mass of 0.5 kg and the encouraging results are reported here; an accent is placed on a big detector of 40 kg in construction at the Milano-Bicocca University and INFN.

astro-ph.IM

A new concept for streamer quenching in resistive plate chambers

In this paper we propose a new concept for streamer quenching in Resistive Plate Chambers (RPCs). In our approach, the multiplication process is quenched by the appropriate design of a mechanical structure inserted between the two resistive electrodes. We show that stable performance is achieved with binary gas mixtures based on argon and a small fraction of isobutane. Fluorocarbons, deemed responsible for the degradation of the electrode inner surface of RPC detectors, are thus fully eliminated from the gas mixture. This design {also resulted} in a simplified assembly procedure. Preliminary results obtained with a few prototypes of ``Mechanically Quenched RPCs'' and some prospects for future developments are discussed.

physics.ins-det

Measurement of neutrino oscillations by means of a high density detector on the atmospheric neutrino beam

A high-density calorimeter, consisting of magnetized iron planes interleaved by RPCs, as tracking and timing devices, is a good candidate for a next generation experiment on atmospheric neutrinos. With 34 kt of mass and in four years of data taking, this experiment will be sensitive to $ν_μ\to ν_x$ oscillation with $Δm^2 > 6 \times 10^{-5}$ and mixing near to maximal and fully cover the region of oscillation parameters suggested by Super-Kamiokande results. Moreover, the experimental method will enable to measure the oscillation parameters from the modulation of the L/E spectrum ($ν_μ$ disappearance). For $Δm^2 > 3 \times 10^{-3}$ eV$^2$, this experiment can also establish whether the oscillation occurs into a tau or a sterile neutrino, by looking for an excess of muon-less events at high energies produced by upward-going tau neutrinos ($ν_τ$ appearance).

hep-ex