SearcharxivSearch

arXiv subjects

N. Shiga

Publications and source records attributed to N. Shiga.

5 recordsLinked to original sources

Stability Transfer between Two Clock Lasers Operating at Different Wavelengths for Absolute Frequency Measurement of Clock Transition in 87Sr

We demonstrated transferring the stability of one highly stable clock laser operating at 729 nm to another less stable laser operating at 698 nm. The two different wavelengths were bridged using an optical frequency comb. The improved stability of the clock laser at 698 nm enabled us to evaluate the systematic frequency shifts of the Sr optical lattice clock with shorter averaging time. We determined the absolute frequency of the clock transition 1S0 - 3P0 in 87Sr to be 429 228 004 229 873.9 (1.4) Hz referenced to the SI second on the geoid via International Atomic Time (TAI).

physics.atom-ph

Diamagnetic correction to the $\bm{^9}$Be$\bm{^+}$ ground-state hyperfine constant

We report an experimental determination of the diamagnetic correction to the $^9$Be$^+$ ground state hyperfine constant $A$. We measured $A$ = $-625\,008\,837.371(11)$ Hz at a magnetic field $B$ of 4.4609 T. Comparison with previous results, obtained at lower values of $B$ (0.68 T and 0.82 T), yields the diamagnetic shift coefficient $k$ = $2.63(18) \times 10^{-11}$ T$^{-2}$, where $A(B)=A_0\times (1+k B^2)$. The zero-field hyperfine constant $A_0$ is determined to be $-625\,008\,837.044(12)$ Hz. The $g$-factor ratio ${g_I}^\prime/g_J$ is determined to be $2.134\,779\,852\,7(10) \times 10^{-4}$, which is equal to the value measured at lower $B$ to within experimental error. Upper limits are placed on some other corrections to the Breit-Rabi formula. The measured value of $k$ agrees with theoretical estimates.

physics.atom-ph

Simplified motional heating rate measurements of trapped ions

We have measured motional heating rates of trapped atomic ions, a factor that can influence multi-ion quantum logic gate fidelities. Two simplified techniques were developed for this purpose: one relies on Raman sideband detection implemented with a single laser source, while the second is even simpler and is based on time-resolved fluorescence detection during Doppler recooling. We applied these methods to determine heating rates in a microfrabricated surface-electrode trap made of gold on fused quartz, which traps ions 40 microns above its surface. Heating rates obtained from the two techniques were found to be in reasonable agreement. In addition, the trap gives rise to a heating rate of 300 plus or minus 30 per second for a motional frequency of 5.25 MHz, substantially below the trend observed in other traps.

quant-ph

A microfabricated surface-electrode ion trap in silicon

The prospect of building a quantum information processor underlies many recent advances ion trap fabrication techniques. Potentially, a quantum computer could be constructed from a large array of interconnected ion traps. We report on a micrometer-scale ion trap, fabricated from bulk silicon using micro-electromechanical systems (MEMS) techniques. The trap geometry is relatively simple in that the electrodes lie in a single plane beneath the ions. In such a trap we confine laser-cooled 24Mg+ ions approximately 40 microns above the surface. The fabrication technique and planar electrode geometry together make this approach amenable to scaling up to large trap arrays. In addition we observe that little laser cooling light is scattered by the electrodes.

quant-ph

A microfabricated surface-electrode ion trap for scalable quantum information processing

We demonstrate confinement of individual atomic ions in a radio-frequency Paul trap with a novel geometry where the electrodes are located in a single plane and the ions confined above this plane. This device is realized with a relatively simple fabrication procedure and has important implications for quantum state manipulation and quantum information processing using large numbers of ions. We confine laser-cooled Mg-24 ions approximately 40 micrometer above planar gold electrodes. We measure the ions' motional frequencies and compare them to simulations. From measurements of the escape time of ions from the trap, we also determine a heating rate of approximately five motional quanta per millisecond for a trap frequency of 5.3 MHz.

quant-ph