SearcharxivSearch

arXiv subjects

N. Smirnov

Publications and source records attributed to N. Smirnov.

18 recordsLinked to original sources

Lumped-element two-section impedance-matched SNAIL parametric amplifier

Broadband impedance-matched Josephson parametric amplifiers are key components for high-fidelity single-shot multi-qubit readout. Nowadays, several types of impedance matched parametric amplifiers have been proposed: the first is an impedance-matched parametric amplifier based on a Klopfenstein taper, and the second is an impedance-matched parametric amplifier based on auxiliary resonators. Here, we present the quantum-limited 3-wave-mixing lumped-element SNAIL parametric amplifier with two-units impedance matching transformer. A two-pole Chebyshev matching network with shunted resonators based on parallel-plate capacitors and superconducting planar coil. Operating in a flux-pumped mode, we experimentally demonstrate an average gain of $15dB$ across a $600MHz$ bandwidth, along with an average saturation power of $-107dBm$ and quantum-limited noise temperature.

quant-ph

Angstrom-scale ion-beam engineering of ultrathin buried oxides for quantum and neuro-inspired computing

Multilayer nanoscale systems incorporating buried ultrathin tunnel oxides, 2D materials, and solid electrolytes are crucial for next-generation logics, memory, quantum and neuro-inspired computing. Still, an ultrathin layer control at angstrom scale is challenging for cutting-edge applications. Here we introduce a scalable approach utilizing focused ion-beam annealing for buried ultrathin oxides engineering with angstrom-scale thickness control. Our molecular dynamics simulations of Ne+ irradiation on Al/a-AlOx/Al structure confirms the pivotal role of ion generated crystal defects. We experimentally demonstrate its performance on Josephson junction tunning in the resistance range of 2 to 37% with a standard deviation of 0.86% across 25x25 mm chip. Moreover, we showcase +-17 MHz frequency control (+-0.172 A tunnel barrier thickness) for superconducting transmon qubits with coherence times up to 500 us, which is promising for useful fault-tolerant quantum computing. This work ensures ultrathin multilayer nanosystems engineering at the ultimate scale by depth-controlled crystal defects generation.

cond-mat.mes-hall

Broadband SNAIL parametric amplifier with microstrip impedance transformer

Josephson parametric amplifiers have emerged as a promising platform for quantum information processing and squeezed quantum states generation. Travelling wave and impedance-matched parametric amplifiers provide broad bandwidth for high-fidelity single-shot readout of multiple qubit superconducting circuits. Here, we present a quantum-limited 3-wave-mixing parametric amplifier based on superconducting nonlinear asymmetric inductive elements (SNAILs), whose useful bandwidth is enhanced with an on-chip two-section impedance-matching circuit based on microstrip transmission lines. The amplifier dynamic range is increased using an array of sixty-seven SNAILs with 268 Josephson junctions, forming a nonlinear quarter-wave resonator. Operating in a current-pumped mode, we experimentally demonstrate an average gain of $17 dB$ across $300 MHz$ bandwidth, along with an average saturation power of $- 100 dBm$, which can go as high as $- 97 dBm$ with quantum-limited noise performance. Moreover, the amplifier can be fabricated using a simple technology with just a one e-beam lithography step. Its central frequency is tuned over a several hundred megahertz, which in turn broadens the effective operational bandwidth to around $1.5 GHz$.

quant-ph

Results from a Prototype Combination TPC Cherenkov Detector with GEM Readout

A combination Time Projection Chamber-Cherenkov prototype detector has been developed as part of the Detector R&D Program for a future Electron Ion Collider. The prototype was tested at the Fermilab test beam facility to provide a proof of principle to demonstrate that the detector is able to measure particle tracks and provide particle identification information within a common detector volume. The TPC portion consists of a 10x10x10cm3 field cage, which delivers charge from tracks to a 10x10cm2 quadruple GEM readout. Tracks are reconstructed by interpolating the hit position of clusters on an array of 2x10mm2 zigzag pads The Cherenkov component consists of a 10x10cm2 readout plane segmented into 3x3 square pads, also coupled to a quadruple GEM. As tracks pass though the drift volume of the TPC, the generated Cherenkov light is able to escape through sparsely arranged wires making up one side of the field cage, facing the CsI photocathode of the Cherenkov detector. The Cherenkov detector is thus operated in a windowless, proximity focused configuration for high efficiency. Pure CF4 is used as the working gas for both detector components, mainly due to its transparency into the deep UV, as well as its high N0. Results from the beam test, as well as results on its particle id capabilities will be discussed.

physics.ins-det

Combination of two Gas Electron Multipliers and a Micromegas as gain elements for a time projection chamber

We measured the properties of a novel combination of two Gas Electron Multipliers with a Micromegas for use as amplification devices in high-rate gaseous time projection chambers. The goal of this design is to minimize the buildup of space charge in the drift volume of such detectors in order to eliminate the standard gating grid and its resultant dead time, while preserving good tracking and particle identification performance. We measured the positive ion back-flow and energy resolution at various element gains and electric fields, using a variety of gases, and additionally studied crosstalk effects and discharge rates. At a gain of 2000, this configuration achieves an ion back-flow below 0.4% and an energy resolution better than $σ/\text{E}=12\%$ for $^{55}$Fe X-rays.

physics.ins-det

Cosmic Ray Test of Mini-drift Thick Gas Electron Multiplier Chamber for Transition Radiation Detector

A thick gas electron multiplier (THGEM) chamber with an effective readout area of 10$\times$10 cm$^{2}$ and a 11.3 mm ionization gap has been tested along with two regular gas electron multiplier (GEM) chambers in a cosmic ray test system. The thick ionization gap makes the THGEM chamber a mini-drift chamber. This kind mini-drift THGEM chamber is proposed as part of a transition radiation detector (TRD) for identifying electrons at an Electron Ion Collider (EIC) experiment. Through this cosmic ray test, an efficiency larger than 94$\%$ and a spatial resolution $\sim$220 $μ$m are achieved for the THGEM chamber at -3.65 kV. Thanks to its outstanding spatial resolution and thick ionization gap, the THGEM chamber shows excellent track reconstruction capability. The gain uniformity and stability of the THGEM chamber are also presented.

physics.ins-det

First observation of Cherenkov rings with a large area CsI-TGEM-based RICH prototype

We have built a RICH detector prototype consisting of a liquid C6F14 radiator and six triple Thick Gaseous Electron Multipliers (TGEMs), each of them having an active area of 10x10 cm2. One triple TGEM has been placed behind the liquid radiator in order to detect the beam particles, whereas the other five have been positioned around the central one at a distance to collect the Cherenkov photons. The upstream electrode of each of the TGEM stacks has been coated with a 0.4 micron thick CsI layer. In this paper, we will present the results from a series of laboratory tests with this prototype carried out using UV light, 6 keV photons from 55Fe and electrons from 90Sr as well as recent results of tests with a beam of charged pions where for the first time Cherenkov Ring images have been successfully recorded with TGEM photodetectors. The achieved results prove the feasibility of building a large area Cherenkov detector consisting of a matrix of TGEMs.

physics.ins-det

VHMPID: a new detector for the ALICE experiment at LHC

This article presents the basic idea of VHMPID, an upgrade detector for the ALICE experiment at LHC, CERN. The main goal of this detector is to extend the particle identification capabilities of ALICE to give more insight into the evolution of the hot and dense matter created in Pb-Pb collisions. Starting from the physics motivations and working principles the challenges and current status of development is detailed.

hep-ex

The Forward GEM Tracker of STAR at RHIC

The STAR experiment at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL) is in the process of designing and constructing a forward tracking system based on triple GEM technology. This upgrade is necessary to give STAR the capability to reconstruct and identify the charge sign of W bosons over an extended rapidity range through their leptonic decay mode into an electron (positron) and a neutrino. This will allow a detailed study of the flavor-separated spin structure of the proton in polarized p + p collisions uniquely available at RHIC. The Forward GEM Tracker FGT will consist of six triple GEM disks with an outer radius of ~39 cm and an inner radius of ~10.5 cm, arranged along the beam pipe, covering the pseudo-rapidity range from 1.0 to 2.0 over a wide range of collision vertices. The GEM foils will be produced by Tech-Etch, Inc. Beam tests with test detectors using 10 cm x 10 cm Tech-Etch GEM foils and a two dimensional orthogonal strip readout have demonstrated a spatial resolution of 70 um or better and high efficiency.

physics.ins-det

New Prototype Multi-gap Resistive Plate Chambers with Long Strips

A new kind of Multi-gap Resistive Plate Chamber (MRPC) has been built for the large-area Muon Telescope Detector (MTD) for the STAR experiment at RHIC. These long read-out strip MRPCs (LMRPCs) have an active area of 87.0 x 17.0 cm2 and ten 250 um-thick gas gaps arranged as a double stack. Each read-out strip is 2.5 cm wide and 90 cm long. The signals are read-out at both ends of each strip. Cosmic ray tests indicate a time resolution of ~70 ps and a detection efficiency of greater than 95%. Beam tests performed at T963 at Fermilab indicate a time resolution of 60-70 ps and a spatial resolution of ~1 cm along the strip direction.

physics.ins-det

Development of Tracking Detectors with industrially produced GEM Foils

The planned tracking upgrade of the STAR experiment at RHIC includes a large-area GEM tracker used to determine the charge sign of electrons and positrons produced from W+(-) decays. For such a large-scale project commercial availability of GEM foils is necessary. We report first results obtained with a triple GEM detector using GEM foils produced by Tech-Etch Inc. of Plymouth, MA, USA. Measurements of gain uniformity, long-term stability as well as measurements of the energy resolution for X-Rays are compared to results obtained with an identical detector using GEM foils produced at CERN. A quality assurance procedure based on optical tests using an automated high-resolution scanner has been established, allowing a study of the correlation of the observed behavior of the detector and the geometrical properties of the GEM foils. Detectors based on Tech-Etch and CERN produced foils both show good uniformity of the gain over the active area and stable gain after an initial charge-up period, making them well suited for precision tracking applications.

physics.ins-det

Expression of Interest for a Comprehensive New Detector at RHIC II

There are compelling physics questions to be addressed by a new comprehensive detector at a future, high-luminosity RHIC II collider. These form the basis for this Expression of Interest. What precisely are the properties of the strongly-coupled Quark Gluon Plasma (sQGP)? Can a more weakly interacting QGP state be formed and investigated at RHIC? How do particles acquire mass and what is the effect of chiral symmetry restoration on hadronization in a dense medium? What is the chiral structure of the QCD vacuum and its influence on and contributions of different QCD vacuum states to the masses of particles? Is there another phase of matter at low Bjorken-x, i.e. the Color Glass Condensate (CGC)? If present, what are its features and how does it evolve into the QGP? If not, are parton distribution functions understood at low Bjorken-x and can they describe particle production? What are the structure and dynamics inside the proton, including parton spin and orbital angular momentum? What are the contributions of gluons and the QCD sea to the polarization of the proton? What is the flavor-dependence? Are there tests for new physics beyond the Standard Model from spin measurements at RHIC II (such as parity-violating interactions)? We propose that a new comprehensive detector system is needed for RHIC II to address these questions adequately and in an effective way.

nucl-ex

Search for light pseudoscalar sgoldstino in K- decays

A search for the light pseudoscalar sgoldstino production in the three body K- decay K-->pipi0P has been performed with the ISTRA+ detector exposed to the 25 GeV negative secondary beam of the U70 proton synchrotron. No signal is seen. An upper limit for the branching ratio Br(K->pipi0P), at 90% confidence level, is found to be around 9*10**-6 in the effective mass m(P) range from 0 till 200 MeV, excluding the region near m(pi0) where it degrades to 3.5*10**-5.

hep-ex

A Comprehensive New Detector for Detailed Study of the Quark Gluon Plasma, Initial Conditions and Spin Physics at RHIC II

A case is presented for compelling physics at a high luminosity RHIC II collider and a comprehensive new detector system to address this physics. The experimental focus is on detailed jet tomography of the quark gluon plasma (QGP), measuring gluon saturation in the nucleus, investigating the color glass condensate, measuring effects of the QCD vacuum on particle masses, determining the structure and dynamics within the proton, and possible new phenomena. The physics and detector capabilities are introduced.

nucl-ex

Identification of High $\rm p_{\perp}$ Particles with the STAR-RICH Detector

The STAR-RICH detector extends the particle identification capapbilities of the STAR experiment for charged hadrons at mid-rapidity. This detector represents the first use of a proximity-focusing CsI-based RICH detector in a collider experiment. It provides identification of pions and kaons up to 3 GeV/c and protons up to 5 GeV/c. The characteristics and performance of the device in the inaugural RHIC run are described.

nucl-ex

Study of the K- -> mu- nu pi0 decay

The decay $K^{-} \to μ^{-} \barν π^{0}$ has been studied using in-flight decays detected with ``ISTRA+'' setup operating in the 25 GeV negative secondary beam of the U-70 PS. About 112K events were used for the analysis. The $λ_{+}$ and $λ_{0}$ slope parameters of the decay formfactors $f_{+}(t)$, $f_{0}(t)$ have been measured : $λ_{+}= 0.0321 \pm 0.004$(stat) $\pm 0.002$(syst) $λ_{0}= 0.0209 \pm 0.004$(stat) $\pm 0.002$(syst); the correlation $d λ_{0}/d λ_{+}=-0.46$ The limits on the possible tensor and scalar couplings have been derived: $f_{T}/f_{+}(0)=-0.021 \pm 0.028$(stat) $\pm 0.014$(theory); $f_{S}/f_{+}(0)=0.004 \pm 0.005$(stat) $\pm 0.005$(theory)

hep-ph

Study of the K- -> pi0 e- nu decay

The decay K- -> pi0 e- nu has been studied using in-flight decays detected with "ISTRA+" setup operating at the 25 GeV negative secondary beam of the U-70 PS. About 130K events were used for the analysis. The lambda_+ parameter of the vector formfactor has been measured: lambda_+ = 0.0293 +- 0.0015(stat) +- 0.002(syst). The limits on the possible tensor and scalar couplings have been derived: f_T/f_+(0)=-0.044 +0.059 -0.057 (stat) f_S/f_+(0)=-0.020 +0.025 -0.016 (stat)

hep-ex