SearcharxivSearch

arXiv subjects

N. Terunuma

Publications and source records attributed to N. Terunuma.

18 recordsLinked to original sources

The Development of Low-Q Cavity Type Beam Position Monitor with a Position Resolution of Nanometer for Future Colliders

The nano-meter beam size in future linear colliders requires very high resolution beam position monitor since higher resolution allows more accurate position measurement in the interaction point. We developed and tested a low-Q C-band beam position monitor with position resolution of nanometer. The C-band BPM was tested for the fast beam feedback system at the interaction point of ATF2 in KEK, in which C-band beam position monitor is called to IPBPM (Interaction Point Beam Position Monitor). The average position resolution of the developed IPBPMs was measured to be 10.1 nm at a nominal beam charge of $87\%$ of ATF2. From the measured beam position resolution, we can expect beam position resolution of around 8.8 nm and 4.4 nm with nominal ATF2 and ILC beam charge conditions, respectively, in which the position resolution is below the vertical beam size in ILC. In this paper, we describe the development of the IPBPM and the beam test results at the nanometer level in beam position resolution

physics.acc-ph

Beam halo from Touschek scattering in the KEK Accelerator Test Facility

Beam halo is one of the crucial issues limiting the machine performance and causing radioactivation in high-intensity accelerators. A clear picture of beam-halo formation is of great importance for successful suppression of the undesired beam loss. We present numerical and experimental studies of transverse and longitudinal halos in the KEK Accelerator Test Facility. The fair accordance between predictions and observations in various conditions indicates that the Touschek scattering is the dominant mechanism forming the horizontal and momentum halos.

physics.acc-ph

A sub-micron resolution, bunch-by-bunch beam trajectory feedback system and its application to reducing wakefield effects in single-pass beamlines

A high-precision intra-bunch-train beam orbit feedback correction system has been developed and tested in the ATF2 beamline of the Accelerator Test Facility at the High Energy Accelerator Research Organization in Japan. The system uses the vertical position of the bunch measured at two beam position monitors (BPMs) to calculate a pair of kicks which are applied to the next bunch using two upstream kickers, thereby correcting both the vertical position and trajectory angle. Using trains of two electron bunches separated in time by 187.6~ns, the system was optimised so as to stabilize the beam offset at the feedback BPMs to better than 350~nm, yielding a local trajectory angle correction to within 250~nrad. The quality of the correction was verified using three downstream witness BPMs and the results were found to be in agreement with the predictions of a linear lattice model used to propagate the beam trajectory from the feedback region. This same model predicts a corrected beam jitter of c.~1~nm at the focal point of the accelerator. Measurements with a beam size monitor at this location demonstrate that reducing the trajectory jitter of the beam by a factor of 4 also reduces the increase in the measured beam size as a function of beam charge by a factor of c.~1.6.

physics.acc-ph

Evaluation of Beam Halo from Beam-Gas Scattering at the KEK-ATF

In circular colliders, as well as in damping rings and synchrotron radiation light sources, beam halo is one of the critical issues limiting the performance as well as potentially causing component damage and activation. It is imperative to clearly understand the mechanisms that lead to halo formation and to test the available theoretical models. Elastic beam-gas scattering can drive particles to large oscillation amplitudes and be a potential source of beam halo. In this paper, numerical estimation and Monte Carlo simulations of this process at the ATF of KEK are presented. Experimental measurements of beam halo in the ATF2 beam line using a diamond sensor detector are also described, which clearly demonstrates the influence of the beam-gas scattering process on the transverse halo distribution.

physics.acc-ph

Sub - THz Radiation from Dielectric Capillaries with Reflectors

In this report we present experimental investigations of THz radiation generated from a corrugated and a non-corrugated capillary with reflectors, using a femtosecond electron beam of LUCX accelerator at KEK, Japan. We discuss measurements of radiation angular distributions and their comparison with Particle In Cell simulations, and also investigate an off-central propagation of the beam in the capillaries based on experimental measurements and simulations.

physics.acc-ph

Development of optical resonant cavities for laser-Compton scattering

We have been developing optical resonant cavities for laser-Compton scattering experiment at the Accelerator Test Facility in KEK. The main subject of the R&D is to increase laser pulse energy by coherently accumulating the pulses in an optical resonant cavity. We report previous results, current status and future prospects, including a new idea of an optical resonant cavity.

physics.acc-ph

Femtosecond response time measurements of a Cs2Te photocathode

We present the response time measurements of a Cs2Te photocathode illuminated with two 100 fs duration, variable time separation laser pulses at 266 nm wavelength. The response time was confirmed in dispersive region downstream of a 12-cell standing wave S-band acceleration structure using a well-known RF zero-crossing technique. At the same time it was also measured by changing mechanical path-length difference between two micro-bunches. Both methods agree that Cs2Te photocathode time response is of the order of 250 fs and thereby it is possible to generate and control a THz sequence of relativistic electron bunches by a conventional S-band RF gun. This result further opens a possibility to construct wide-range tunable THz FEL.

physics.acc-ph

Monochromaticity of coherent Smith-Purcell radiation from finite size grating

Investigation of coherent Smith-Purcell Radiation (SPR) spectral characteristics was performed both experimentally and by numerical simulation. The measurement of SPR spectral line shapes of different diffraction orders was carried out at KEK LUCX facility. A pair of room-temperature Schottky barrier diode (SBD) detectors with sensitivity bands of $60-90$~GHz and $320-460$~GHz was used in the measurements. Reasonable agreement of experimental results and simulations performed with CST Studio Suite justifies the use of different narrow-band SBD detectors to investigate different SPR diffraction orders. It was shown that monochromaticity of the SPR spectral lines increases with diffraction order. The comparison of coherent transition radiation and coherent SPR intensities in sub-THz frequency range showed that the brightnesses of both radiation mechanisms were comparable. A fine tuning feasibility of the SPR spectral lines is discussed.

physics.acc-ph

Laserwire at the Accelerator Test Facility 2 with Sub-Micrometre Resolution

A laserwire transverse electron beam size measurement system has been developed and operated at the Accelerator Test Facility 2 (ATF2) at KEK. Special electron beam optics were developed to create an approximately 1 x 100 μm (vertical x horizontal) electron beam at the laserwire location, which was profiled using a 150 mJ, 71 ps laser pulse with a wavelength of 532 nm. The precise characterisation of the laser propagation allows the non-Gaussian transverse profiles of the electron beam caused by the laser divergence to be deconvolved. A minimum vertical electron beam size of 1.07 ${\pm}$ 0.06 (stat.) ${\pm}$ 0.05 (sys.) μm was measured. A vertically focussing quadrupole just before the laserwire was varied whilst making laserwire measurements and the projected vertical emittance was measured to be 82.56 ${\pm}$ 3.04 pm rad.

physics.acc-ph

Principal Component Analysis of Cavity Beam Position Monitor Signals

Model-independent analysis (MIA) methods are generally useful for analysing complex systems in which relationships between the observables are non-trivial and noise is present. Principle Component Analysis (PCA) is one of MIA methods allowing to isolate components in the input data graded to their contribution to the variability of the data. In this publication we show how the PCA can be applied to digitised signals obtained from a cavity beam position monitor (CBPM) system on the example of a 3-cavity test system installed at the Accelerator Test Facility 2 (ATF2) at KEK in Japan. We demonstrate that the PCA based method can be used to extract beam position information, and matches conventional techniques in terms of performance, while requiring considerably less settings and data for calibration.

physics.acc-ph

Observation of the Stimulated Coherent Diffraction Radiation in an Open Resonator at LUCX Facility

We present an initial test of a new type of a pre-bunched beam pumped free electron maser based on Stimulated Coherent Diffraction Radiation (SCDR) generated in an open resonator. An ultra-fast Schottky Barrier Diode (time response $<1\,$ns) has enabled to investigate the properties of the radiation stored in the cavity as well as the intrinsic properties of the cavity itself. We observed a turn-by-turn SCDR generated by a multibunch beam. When the cavity length was exactly a half of the bunch spacing a clear resonance was observed. Moreover, turn-by-turn measurements revealed the cavity quality factor of $72.88$, which was rather high for an open resonator in the wavelength range of $3-5\,$mm. An exponential growth of the photon intensity as a function of the number of bunches was also demonstrated.

physics.acc-ph

Cavity beam position monitor system for the Accelerator Test Facility 2

The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at 6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The cavities, electronics, and digital processing are described. The resolution of the C-band system with attenuators was determined to be approximately 250 nm and 1 m for the S-band system. Without attenuation the best recorded C-band cavity resolution was 27 nm.

physics.acc-ph

High Resolution BPM Upgrade for the ATF Damping Ring at KEK

A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and processing, and also implements a new automatic gain error correction schema. The technical concept and realization as well as results of beam studies are presented.

physics.acc-ph

Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

physics.acc-ph

Effect of Compton Scattering on the Electron Beam Dynamics at the ATF Damping Ring

Compton scattering provides one of the most promising scheme to obtain polarized positrons for the next generation of $e^-$ -- $e^+$ colliders. Moreover it is an attractive method to produce monochromatic high energy polarized gammas for nuclear applications and X-rays for compact light sources. In this framework a four-mirror Fabry-Pérot cavity has been installed at the Accelerator Test Facility (ATF - KEK, Tsukuba, Japan) and is used to produce an intense flux of polarized gamma rays by Compton scattering \cite{ipac-mightylaser}. For electrons at the ATF energy (1.28 GeV) Compton scattering may result in a shorter lifetime due to the limited bucket acceptance. We have implemented the effect of Compton scattering on a 2D tracking code with a Monte-Carlo method. This code has been used to study the longitudinal dynamics of the electron beam at the ATF damping ring, in particular the evolution of the energy spread and the bunch length under Compton scattering. The results obtained are presented and discussed. Possible methods to observe the effect of Compton scattering on the ATF beam are proposed.

physics.acc-ph

Shintake Monitor in ATF2: Performance Evaluation

The beam test for the Shintake monitor succeeded in measuring signal modulation with the laser interference fringe pattern in November 2009. We have studied the error sources, and evaluated the systematic error to be less than 30% for 1 minute measurements. This paper centers on the evaluation of the Shintake monitor performance through analyzing beam tests deta. Most systematic error sources are well understood, enabling accurate measurement of the beam size when it reaches 37 nm.

physics.ins-det

Design of a Polarised Positron Source Based on Laser Compton Scattering

We describe a scheme for producing polarised positrons at the ILC from polarised X-rays created by Compton scattering of a few-GeV electron beam off a CO2 or YAG laser. This scheme is very energy effective using high finesse laser cavities in conjunction with an electron storage ring.

physics.acc-ph

Double Kicker system in ATF

A double kicker system which extracts the ultra-low emittance multi-bunch beam stably from ATF damping ring was developed. The performance of the system was studied comparing an orbit jitter with single kicker extraction in single bunch mode. The position jitter reduction was estimated from the analysis of the extraction orbits. The reduction was confirmed for the double kicker system within a resolution of BPMs. More precise tuning of the system with a wire scanner has been tried by changing a beta function at the second kicker to get more reduction of kick angle jitter. The results of these studies are described in detail.

physics.acc-ph