Searcharxiv⌕ Search

arXiv subjects

N. Y. Kim

Publications and source records attributed to N. Y. Kim.

At least 37 records · Page 2Linked to original sources

A measurement of the scintillation decay time constant of nuclear recoils in liquid xenon with the XMASS-I detector

We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) and a xenon nucleus. The inner detector volume contains 832 kg of LXe. $^{252}$Cf was used as an external neutron source for irradiating the detector. The scintillation decay time constant of the resulting neutron induced NR was evaluated by comparing the observed photon detection times with Monte Carlo simulations. Fits to the decay time prefer two decay time components, one for each of the Xe$_{2}^{*}$ singlet and triplet states, with $τ_{S}$ = 4.3$\pm$0.6 ns taken from prior research, $τ_{T}$ was measured to be 26.9$^{+0.7}_{-1.1}$ ns with a singlet state fraction F$_{S}$ of 0.252$^{+0.027}_{-0.019}$.We also evaluated the performance of pulse shape discrimination between NR and electron recoil (ER) with the aim of reducing the electromagnetic background in WIMP searches. For a 50\% NR acceptance, the ER acceptance was 13.7${\pm}$1.0\% and 4.1${\pm}$0.7\% in the energy ranges of 5--10 keV$_{\rm ee}$ and 10--15 keV$_{\rm ee}$, respectively.

physics.ins-det↗

Search for sub-GeV dark matter by annual modulation using XMASS-I detector

A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in a total exposure of 2.38 ton-years. No significant modulation signal was observed and 90% confidence level upper limits of $1.6 \times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section. This is the first experimental result of a search for DM mediated by the bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV region (4-20 GeV) was conducted with a lower energy threshold than previous analysis of XMASS. Elastic nuclear scattering was used to search down to a nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9 $\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.

astro-ph.CO↗

Search for dark matter in the form of hidden photons and axion-like particles in the XMASS detector

Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixing of hidden photons and the coupling constant $g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$, resulting in $α' / α< 6 \times 10^{-26}$ and $g_{Ae} < 4 \times 10^{-13}$. These limits are the most stringent derived from both direct and indirect searches to date.

astro-ph.CO↗

The COSINE-100 Data Acquisition System

COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator veto, and 37 muon detector panels. We present details of the data acquisition system of COSINE-100, including waveform storage using flash analog-to-digital converters for crystal events and integrated charge storage using charge-sensitive analog-to-digital converters for liquid scintillator and plastic scintillator muon veto events. We also discuss several trigger conditions developed in order to distinguish signal events from photomultiplier noise events. The total trigger rate observed for the crystal/liquid scintillator (plastic scintillator) detector is 15 Hz (24 Hz).

physics.ins-det↗

Background model for the NaI(Tl) crystals in COSINE-100

The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal detectors located in the Yangyang Underground Laboratory (Y2L). To understand measured backgrounds in the NaI(Tl) crystals we have performed Monte Carlo simulations using the Geant4 toolkit and developed background models for each crystal that consider contributions from both internal and external sources, including cosmogenic nuclides. The background models are based on comparisons of measurement data with Monte Carlo simulations that are guided by a campaign of material assays and are used to evaluate backgrounds and identify their sources. The average background level for the six crystals (70 kg total mass) that are studied is 3.5 counts/day/keV/kg in the (2-6) keV energy interval. The dominant contributors in this energy region are found to be $^{210}$Pb and $^3$H.

astro-ph.IM↗

Direct dark matter search by annual modulation with 2.7 years of XMASS-I data

An annual modulation signal due to the Earth orbiting around the Sun would be one of the strongest indications of the direct detection of dark matter. In 2016, we reported a search for dark matter by looking for this annual modulation with our single-phase liquid xenon XMASS-I detector. That analysis resulted in a slightly negative modulation amplitude at low energy. In this work, we included more than one year of additional data, which more than doubles the exposure to 800 live days with the same 832 kg target mass. When we assume weakly interacting massive particle (WIMP) dark matter elastically scattering on the xenon target, the exclusion upper limit for the WIMP-nucleon cross section was improved by a factor of 2 to 1.9$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ at 90\% confidence level with our newly implemented data selection through a likelihood method. For the model-independent case, without assuming any specific dark matter model, we obtained more consistency with the null hypothesis than before with a $p$-value of 0.11 in the 1$-$20 keV energy region. This search probed this region with an exposure that was larger than that of DAMA/LIBRA. We also did not find any significant amplitude in the data for periodicity with periods between 50 and 600 days in the energy region between 1 to 6 keV.

astro-ph.CO↗

Measurement of low-energy background events due to $^{222}$Rn contamination on the surface of a NaI(Tl) crystal

It has been known that decays of daughter elements of $^{222}$Rn on the surface of a detector cause significant background at energies below 10 keV. In particular $^{210}$Pb and $^{210}$Po decays on the crystal surface result in significant background for dark matter search experiments with NaI(Tl) crystals. In this report, measurement of $^{210}$Pb and $^{210}$Po decays on surfaces are obtained by using a $^{222}$Rn contaminated crystal. Alpha decay events of $^{210}$Po on the surface are measured by coincidence requirements of two attached crystals. Due to recoiling of $^{206}$Pb, rapid nuclear recoil events are observed. A mean time characterization demonstrates that $^{206}$Pb recoil events can be statistically separated from those of sodium or iodine nuclear recoil events, as well as electron recoil events.

astro-ph.IM↗

Study of fast neutron detector for COSINE-100 experiment

A monitoring system for fast neutrons is planned in the COSINE experiment, a dark matter experiment with NaI crystals. We pursued several R&D approaches for a neutron detector using a liquid scintillator (LS). A pulse shape discrimination (PSD) technique is used for the identification of neutron events and the PSD properties of two different LS were compared. A good separation power between neutrons and $γ$ has been achieved for energies between 200 keVee to 1500 keVee. The combination of alumina adsorption, filtration, and water extraction is effective in purifying the LS, which leads to a reduction in the $α$ contamination by $^{210}$Po of more than a factor of two. The measured activities of the internal $α$ are 0.36$\pm$0.04~mBq/kg and 0.21$\pm$0.03~mBq/kg before and after purification, respectively.

physics.ins-det↗

Improved search for two-neutrino double electron capture on $^{124}$Xe and $^{126}$Xe using particle identification in XMASS-I

We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant signal was found when fitting the observed energy spectra with the expected signal and background. Therefore, we set the most stringent lower limits on the half-lives at $2.1 \times 10^{22}$ and $1.9 \times 10^{22}$ years for $^{124}$Xe and $^{126}$Xe, respectively, with 90% confidence level. These limits improve upon previously reported values by a factor of 4.5.

nucl-ex↗

Initial Performance of the COSINE-100 Experiment

COSINE is a dark matter search experiment based on an array of low background NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly of COSINE-100 was completed in the summer of 2016 and the detector is currently collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment that reported an annual modulation signal. Stable operation has been achieved and will continue for at least two years. Here, we describe the design of COSINE-100, including the shielding arrangement, the configuration of the NaI(Tl) crystal detection elements, the veto systems, and the associated operational systems, and we show the current performance of the experiment.

physics.ins-det↗

Identification of $^{210}$Pb and $^{210}$Po in the bulk of copper samples with a low-background alpha particle counter

We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in the bulk of copper samples using a low-background alpha particle counter. The achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po contaminations in oxygen free copper bulk were identified and measured for the first time. The $^{210}$Pb contaminations of our oxygen free copper samples were 17-40 mBq/kg. Based on our investigation of copper samples in each production step, the $^{210}$Pb in oxygen free copper was understood to be a small residual of an electrolysis process. This method to measure bulk contaminations of $^{210}$Pb and $^{210}$Po could be applied to other materials.

physics.ins-det↗

Muon detector for the COSINE-100 experiment

The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic scintillator panels in the outermost layer of the shield surrounding the COSINE-100 detector. It is used to detect cosmic ray muons in order to understand the impact of the muon annual modulation on dark matter analysis. Assembly and initial performance test of each module have been performed at a ground laboratory. The installation of the detector in Yangyang Underground Laboratory (Y2L) was completed in the summer of 2016. Using three months of data, the muon underground flux was measured to be 328 $\pm$ 1(stat.)$\pm$ 10(syst.) muons/m$^2$/day. In this report, the assembly of the muon detector and the results from the analysis are presented.

physics.ins-det↗

Search for solar Kaluza-Klein axion by annual modulation with the XMASS-I detector

In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits around the Sun. They would decay into two photons inside a terrestrial detector. The event rate is expected to modulate annually depending on the distance from the Sun. We have searched for the annual modulation signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant event rate modulation is found, and hence we set the first experimental constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\, \mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of $\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number of extra dimensions $n = 2$, and the number of extra dimensions $δ= 2$ that axions can propagate in.

hep-ex↗

Understanding NaI(Tl) crystal background for dark matter searches

We have developed ultra-low-background NaI(Tl) crystals to reproduce the DAMA results with the ultimate goal of achieving purity levels that are comparable to or better than those of the DAMA/LIBRA crystals. Even though the achieved background level does not approach that of DAMA/LIBRA, it is crucial to have a quantitative understanding of the backgrounds. We have studied background simulations toward a deeper understanding of the backgrounds and developed background models for a 9.16-kg NaI(Tl) crystal used in the test arrangement. In this paper we describe the contributions of background sources quantitatively by performing Geant4 Monte Carlo simulations that are fitted to the measured data to quantify the unknown fractions of the background compositions. In the fitted results, the overall simulated background spectrum well describes the measured data with a 9.16-kg NaI(Tl) crystal and shows that the background sources are dominated by surface $^{210}$Pb and internal $^{40}$K in the 2 to 6-keV energy interval, which produce 2.4 counts/day/keV/kg (dru) and 0.5 dru, respectively.

astro-ph.IM↗

Performance of a prototype active veto system using liquid scintillator for a dark matter search experiment

We report the performance of an active veto system using a liquid scintillator with NaI(Tl) crystals for use in a dark matter search experiment. When a NaI(Tl) crystal is immersed in the prototype detector, the detector tags 48% of the internal K-40 background in the 0-10 keV energy region. We also determined the tagging efficiency for events at 6-20 keV as 26.5 +/- 1.7% of the total events, which corresponds to 0.76 +/- 0.04 events/keV/kg/day. According to a simulation, approximately 60% of the background events from U, Th, and K radioisotopes in photomultiplier tubes are tagged at energies of 0-10 keV. Full shielding with a 40-cm-thick liquid scintillator can increase the tagging efficiency for both the internal K-40 and external background to approximately 80%.

astro-ph.IM↗

A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector

We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming two decay components, $τ_1$ and $τ_2$, the decay time constant $τ_2$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with $τ_1 \sim 2$ ns was necessary to reproduce data. Energy dependencies of $τ_2$ and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.

physics.ins-det↗

Direct dark matter search by annual modulation in XMASS-I

A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without assuming any specific dark matter model but including electron/$γ$ events, showed a slight negative amplitude. The $p$-values obtained with two independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we obtained 90\% C.L. upper bounds that can be used to test various models. This is the first extensive annual modulation search probing this region with an exposure comparable to DAMA/LIBRA.

astro-ph.CO↗

Search for two-neutrino double electron capture on $^{124}$Xe with the XMASS-I detector

Double electron capture is a rare nuclear decay process in which two orbital electrons are captured simultaneously in the same nucleus. Measurement of its two-neutrino mode would provide a new reference for the calculation of nuclear matrix elements whereas observation of its neutrinoless mode would demonstrate lepton number violation. A search for two-neutrino double electron capture on $^{124}$Xe is performed using 165.9 days of data collected with the XMASS-I liquid xenon detector. No significant excess above background was observed and we set a lower limit on the half-life as $4.7 \times 10^{21}$ years at 90% confidence level. The obtained limit has ruled out parts of some theoretical expectations. We obtain a lower limit on the $^{126}$Xe two-neutrino double electron capture half-life of $4.3 \times 10^{21}$ years at 90% confidence level as well.

nucl-ex↗