Searcharxiv⌕ Search

arXiv subjects

N. Yu. Muchnoi

Publications and source records attributed to N. Yu. Muchnoi.

At least 37 records · Page 2Linked to original sources

Measurement of the $e^+e^- \to ηπ^+π^-$ cross section with the SND detector at the VEPP-2000 collider

The $e^+e^- \to ηπ^+π^-$ cross section is measured at the SND detector in the $η$ decay mode $η\to 3π^0$. The analysis is based on the data sample with an integrated luminosity of 32.7 pb$^{-1}$ collected at the VEPP-2000 $e^+e^-$ collider in the center-of-mass energy range $\sqrt{s}=1.075-2.000$ GeV. The data obtained in the $η\to 3π^0$ decay mode are found to be in agreement with the previous SND measurements in the $η\to γγ$ mode. Therefore the measurements in the two modes are combined.

hep-ex↗

Energy scale calibration of KEDR detector tagging system

The tagging system of the KEDR detector is a symmetrical focusing magnetic spectrometer for electrons and positrons scattered at small angles; it is embedded into the lattice of the VEPP-4M collider and intended for two-photon processes study. It measures scattered electron energy with resolution $ΔE/E_0=0.03\%...0.6\%$ ($E_0$ is the beam energy). For precise energy scale calibration two methods are used: tagging of bremsstrahlung electron/positron by the photon energy measured by BGO calorimeter, and direct calibration using Compton backscattering spectrum edge. This report covers design and current status of the calibration system.

physics.ins-det↗

Proposal for VEPP-4M beam energy measurement using magnetic spectrometer with Compton calibration and photon detector

A method for circular e$^-$/e$^+$ accelerator beam energy measurement is proposed. Coordinate of an electron (or a positron) in a focusing magnetic spectrometer built in a circular accelerator depends on its energy, two spectrometer parameters, and the circulating beam energy. The spectrometer parameters can be defined using minimum electron energies from Compton backscattering with two laser wavelengths, and an additional photon coordinate detector. The photon detector is calibrated at once at well-known beam energy. The VEPP-4M collider has appropriate equipment for the method implementation: built-in focusing magnetic spectrometer, Compton calibration system with two lasers and a photon coordinate detector. Thus, the proposed technique could be implemented with minimum efforts; tests and further upgrade are planned. The beam energy can be defined with expected uncertainty better than $10^{-4}$.

physics.ins-det↗

Measurement of $R$ between 1.84 and 3.05 GeV at the KEDR detector

Using the KEDR detector at the VEPP-4M $e^+e^-$ collider, we have determined the values of $R$ at thirteen points of the center-of-mass energy between 1.84 and 3.05 GeV. The achieved accuracy is about or better than $3.9\%$ at most of the energy points with a systematic uncertainty less than $2.4\%$.

hep-ex↗

Measurement of $R_{\text{uds}}$ and $R$ between 3.12 and 3.72 GeV at the KEDR detector

Using the KEDR detector at the VEPP-4M $e^+e^-$ collider, we have measured the values of $R_{\text{uds}}$ and $R$ at seven points of the center-of-mass energy between 3.12 and 3.72 GeV. The total achieved accuracy is about or better than $3.3\%$ at most of energy points with a systematic uncertainty of about $2.1\%$. At the moment it is the most accurate measurement of $R(s)$ in this energy range.

hep-ex↗

Upgrade of Beam Energy Measurement System at BEPC-II

The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. Many advanced techniques and precise instruments are employed to realize the highly accurate measurement of positron/electron beam energy. During five year's running period, in order to meet the requirement of data taking and improve the capacity of measurement itself, the upgradation of system is continued, which involve the component reformation of laser and optics subsystem, replacement of view-port of the laser to vacuum insertion subsystem, the purchase of electric cooling system for high purity germanium detector, and the improvement of data acquisition and processing subsystem. The upgrading of system guarantees the smooth and efficient measuring of beam energy at BEPC-II and accommodates the accurate offline energy values for further physics analysis at BES-III.

physics.ins-det↗

On a search for the $η\rightarrow e^+ e^-$ decay at the VEPP-2000 $e^+e^-$ collider

A sensitivity of the VEPP-2000 $e^+e^-$ collider in a search for the rare decay $η\rightarrow e^+ e^-$ has been studied. The inverse reaction $e^+ e^- \rightarrow η$ is proposed for this search. We have analyzed a data sample with an integrated luminosity of 108 nb$^{-1}$ collected with the SND detector in the center-of-mass energy range 520-580 MeV and found no background events for the reaction $e^+ e^- \rightarrow η$ in the decay mode $η\toπ^0π^0π^0$. In the absence of background, a sensitivity to ${\cal B}(η\rightarrow e^+ e^-)$ of $10^{-6}$ can be reached during two weeks of VEPP-2000 operation. Such a sensitivity is better than the current upper limit on ${\cal B}(η\rightarrow e^+ e^-)$ by a factor of 2.3.

hep-ex↗

Search for the $η^{\prime}\to e^+e^-$ decay with the SND detector

A search for the process $e^+e^- \to η^\prime$ has been performed with the SND detector at the VEPP-2000 $e^+e^-$ collider. The data were accumulated at the center-of-mass energy of $957.78\pm 0.06$ MeV with an integrated luminosity of about 2.9 pb$^{-1}$. For reconstruction of the $η^\prime$ meson five decay chains have been used: $η^{\prime}\toηπ^+π^-$ followed by the $η$ decays to $γγ$ and $3π^0 $, and $η^{\prime} \to ηπ^0π^0$ followed by the $η$ decays to $π^+π^-π^0$, $γγ$, and $3π^0$. As a result, the upper limit has been set on the $η^\prime$ electronic width: $Γ_{η^{\prime}\to e^+e^-} < 0.0020$ eV at the 90\% confidence level.

hep-ex↗

The system for delivery of IR laser radiaton into high vacuum

The system for insertion of a laser beam into the vacuum chamber of high-energy storage ring is described. The main part of the system is the high-vacuum viewport for the IR radiation, based on ZnSe or GaAs crystals. The design of the viewports is presented.

physics.acc-ph↗

Measurement of the two-photon exchange contribution to the elastic $e^{\pm}p$ scattering cross sections at the VEPP-3 storage ring

The ratio of the elastic $e^+ p$ to $e^- p$ scattering cross sections has been measured precisely, allowing the determination of the two-photon exchange contribution to these processes. This neglected contribution is believed to be the cause of the discrepancy between the Rosenbluth and polarization transfer methods of measuring the proton electromagnetic form factors. The experiment was performed at the VEPP-3 storage ring at beam energies of 1.6 and 1.0 GeV and at lepton scattering angles between $15^\circ$ and $105^\circ$. The data obtained show evidence of a significant two-photon exchange effect. The results are compared with several theoretical predictions.

nucl-ex↗

Search for the process $e^+e^-\to η^\prime(958)$ with the CMD-3 detector

A search for the process $\epem\to η^\prime(958)$ in the $\pipiη\to\pipiγγ$ final state has been performed with the CMD-3 detector at the VEPP-2000 $e^+e^-$ collider. Using an integrated luminosity of 2.69 pb$^{-1}$ collected at the center-of-mass energy \Ecm = 957.68 MeV we set an upper limit for the product of electronic width and branching fractions $Γ_{η^\prime(958)\to\epem}\cdot\BR_{η^\prime(958)\to\pipiη}\cdot\BR_{η\toγγ}<0.00041$ eV at 90\% C.L.

hep-ex↗

Measurement of $J/ψ\toγη_{\rm c}$ decay rate and $η_{\rm c}$ parameters at KEDR

Using the inclusive photon spectrum based on a data sample collected at the $J/ψ$ peak with the KEDR detector at the VEPP-4M $e^+e^-$ collider, we measured the rate of the radiative decay $J/ψ\toγη_{\rm c}$ as well as $η_{\rm c}$ mass and width. Taking into account an asymmetric photon lineshape we obtained $Γ^0_{γη_{\rm c}}=2.98\pm0.18 \phantom{|}^{+0.15}_{-0.33}$ keV, $M_{η_{\rm c}} = 2983.5 \pm 1.4 \phantom{|}^{+1.6}_{-3.6}$ MeV/$c^2$, $Γ_{η_{\rm c}} = 27.2 \pm 3.1 \phantom{|}^{+5.4}_{-2.6}$ MeV.

hep-ex↗

Compton Backscattering for the Calibration of KEDR Tagging System

KEDR detector has the tagging system (TS) to study the gamma-gamma processes. To determine the two-photon invariant mass, the energies of the scattered at small angles electrons and positrons are measured by the magnetic spectrometer embedded into the lattice of the VEPP--4M collider. The energy resolution (scattered electron/positron energy resolution divided by the beam energy) of this spectrometer varies from 0.6% to 0.03% depending on the electron/positron energy. The Compton backscattering of laser radiation on the electron/positron beam is used for the accurate energy scale and resolution calibration of the tagging system. The report covers the design, recent results and current status of the KEDR TS calibration system.

physics.ins-det↗

Beam energy measurements for an experiment on elastic $e^{\pm}p$ scattering at the VEPP-3 storage ring

A precise comparison of the cross sections for the elastic scattering of electrons and positrons on protons was performed recently at the VEPP-3 storage ring in Novosibirsk, Russia. To provide the proposed accuracy, the energies of the electron and positron beams used during the experiment needed to be carefully maintained. This paper describes a special beam energy measurement system used in this experiment. This system is based on measuring the maximum energy of laser photons backscattered from electron and positron beams. It provides continuous beam energy measurements with a total relative uncertainty of less than $4.4 \cdot 10^{-5}$.

physics.ins-det↗

Measurement of the ratio of the leptonic widths $Γ_{ee}/Γ_{μμ}$ for the $J/ψ$ meson

The ratio of the electron and muon widths of the $J/ψ$ meson has been measured using direct $J/ψ$ decays in the KEDR experiment at the VEPP-4M electron-positron collider. The result $Γ_{ee}(J/ψ)/Γ_{μμ}(J/ψ)=1.0022\pm0.0044\pm0.0048\ (0.65\%)$ is in good agreement with the lepton universality. The experience collected during this analysis will be used for a $J/ψ$ lepton width determination with up to 1% accuracy.

hep-ex↗

Parameters of charmonium states from KEDR

We report results of experiments performed with the KEDR detector at the VEPP-4M $e^+e^-$ collider. They include final results for the mass and other parameters of the $J/ψ$, $ψ(2S)$ and $ψ(3770)$ and $J/ψ\toγη_c$ branching fraction determination.

hep-ex↗

A system of beam energy measurement based on the Compton backscattered laser photons for the VEPP-2000 electron-positron collider

The beam energy measurement system for the VEPP-2000 electron-positron collider is described. The method of Compton backscattering of $CO$ laser photons on the electron beam is used. The relative systematic uncertainty of the beam energy determination is estimated as 6\cdot10^{-5}. It was obtained through comparison of the results of the beam energy measurements using the Compton backscattering and resonance depolarization methods.

physics.acc-ph↗