Searcharxiv⌕ Search

arXiv subjects

Naama Golan

Publications and source records attributed to Naama Golan.

2 recordsLinked to original sources

Decision language models as affordable and rapid alternatives to LLM judges of clinical generative AI

Automated judges of clinical artificial intelligence (AI) outputs are necessary, but large language model (LLM) judges are costly and slow at scale. We compared Jev, a decision language model that returns structured judgments, with frontier and open-weight LLM judges in four use cases. On 118 pediatric answers, Jev's agreement with physicians' ordinal quality ratings (Gwet's AC2 0.50; expected score 0.53) matched or exceeded that of seven of 12 LLM judges, including frontier models, Claude Opus 5.5 (0.49) and GPT-6 (0.38). On physician-graded binary HealthBench criteria, Jev matched or exceeded four of six LLM judges. On MedHELM's open-ended tasks, Jev's agreement with a three-LLM jury approached or exceeded the jurors' internal agreement. On HealthBench Professional, Jev matched the benchmark's reference judge, GPT-5.4, on 91% of criteria (other judges, 91-93%). Frontier judges cost 73-294 times more than Jev and took 7-57 times longer. Jev may enable efficient clinical AI evaluation at scale.

cs.AI↗

SpiRadar: Radar-Based Non-Contact Spirometry via Sparse Polynomial Framework

Chronic respiratory diseases affect hundreds of millions of people worldwide, with spirometry serving as the gold standard for pulmonary function assessment. However, conventional spirometry's reliance on mouthpieces and nose clips creates discomfort and technical challenges that can compromise test quality, particularly in pediatric populations where cooperation difficulties are amplified. This study presents SpiRadar, a comprehensive radar-based framework for non-contact spirometry that eliminates physical contact requirements while enabling accurate curve reconstruction, clinical parameter estimation, and bronchodilator response (BDR) assessment. Our key contributions include: (1) a methodological framework integrating physiologically-motivated preprocessing for robust signal extraction, a feature-dependent polynomial transformation linking radar-measured thoracic displacement to spirometric volume curves, and sparse optimization enabling generalization to unseen subjects without individual calibration; (2) a rigorous validation on a pediatric cohort of 39 subjects (ages 6-18 years) undergoing 58 spirometry trials, including healthy children and asthma patients tested pre- and post-bronchodilator, using subject-level leave-one-out cross-validation; (3) clinical-grade performance outperforming alternative non-contact methods, achieving accurate curve reconstruction (mean RMSE: 0.23 +- 0.12 L) and strong correlations (above 0.84) for key spirometric parameters. BDR classification achieved 89.5% accuracy with balanced sensitivity (90.9%) and specificity (87.5%). These results establish clinical feasibility for our non-contact spirometry approach, with particular promise for pediatric asthma monitoring and remote patient care.

eess.SP↗