Searcharxiv⌕ Search

arXiv subjects

Naiara Korta Martiartu

Publications and source records attributed to Naiara Korta Martiartu.

6 recordsLinked to original sources

On phase aberration estimation using common mid-angle speckle correlations

Phase aberrations, despite degrading ultrasound images, also encode valuable information about the spatial distribution of the speed of sound in tissue. In pulse-echo ultrasound, we can quantify them by exploiting speckle correlations. Among existing strategies, correlations between steered acquisitions that share a common mid-angle have proven particularly effective for inferring the speed of sound. Their phases can be linearly related to the phase aberrations undergone by both the incident and reflected wavefronts. This relationship has so far been demonstrated only through geometric arguments based on point reflectors. Here, we develop a rigorous theoretical formalism that extends this relationship to the speckle regime, completing the previously established linear model and clarifying its underlying assumptions. More importantly, we build on this formalism to analyze correlation-phase fluctuations arising from aberration-induced speckle decorrelation. The analysis reveals that phase variance is governed by the relative loss of coherence, which increases approximately linearly with the square of the correlation phases. Local correlation-phase estimates therefore become increasingly uncertain as their magnitude grows. Experimental measurements in a uniform tissue-mimicking phantom show excellent agreement with the predicted variance. Beyond providing a theoretical basis for advancing speed-of-sound imaging, this formalism establishes the accuracy limit of common-mid-angle correlation phases, offering a benchmark for evaluating more advanced aberration-estimation techniques.

physics.med-ph↗

An angular distortion matrix approach for joint wave-speed tomography and aberration correction in scattering media

Despite being one of the most fundamental properties governing wave propagation, the wave-speed distribution is rarely known accurately in reflection imaging. Its estimation relies on analyzing wave distortions undergone by the incident and reflected waves; however, their contribution is difficult to disentangle from the medium reflectivity, particularly in complex media dominated by speckle. Mismatches between assumed and actual wave speeds result in aberrations that degrade the quality of reflectivity images. Yet these aberrations carry information about the underlying wave-speed heterogeneities. Here, we show that an angular distortion matrix, built upon matrix imaging, can unscramble this information to map the wave speed and correct aberrations across the entire field of view. At each point, this matrix isolates the distortions accumulated by the incident and reflected waves along well-defined propagation directions. It reveals strong angular correlations that can be exploited through time-reversal analysis to estimate local phase aberrations, providing observables for wave-speed tomography. The resulting map improves the propagation model used for matrix imaging, after which the process is iterated to refine the wave speed until residual aberrations become negligible. Using ultrasound as proof of concept, we validate the approach in a tissue-mimicking phantom and illustrate its clinical potential in vivo for breast and liver imaging. Sound-speed maps show contrast consistent with a malignant breast lesion and expected values in a healthy liver, while aberration correction sharpens reflectivity images routinely interpreted by clinicians. Beyond ultrasound, the approach extends naturally to any wave modality in which reflection-matrix imaging can be implemented.

physics.app-ph↗

Learning-based Linear Inversion for Quantitative Pulse-Echo Speed-of-Sound Imaging

Computed ultrasound tomography in echo mode generates maps of tissue speed of sound (SoS) from the shift of echoes when detected under varying steering angles. It solves a linearized inverse problem that requires regularization to complement the echo shift data with a priori constraints. Spatial gradient regularization has been used to enforce smooth solutions, but SoS estimates were found to be biased depending on tissue layer geometry. Here, we propose to train a linear operator to minimize SoS errors on average over a large number of random tissue models that sample the distribution of geometries and SoS values expected in vivo. In an extensive simulation study on liver imaging, we demonstrate that biases are strongly reduced, with residual biases being the result of a partial non-linearity in the actual physical problem. This approach can either be applied directly to echo-shift data or to the SoS maps estimated with gradient regularization, where the former shows slightly better performance, but the latter is computationally more efficient. Experimental phantom results confirm the transferability of our results to real ultrasound data.

physics.med-ph↗

Self-Portrait of the Focusing Process in Speckle: II. Gouy Phase Shift for Defocus Correction and Pixel Depth Reassignment

This is the second article in a series of three dealing with the exploitation of speckle for aberration correction and reverberation compensation in reflection imaging. When probing heterogeneous media with waves, we have to cope with multi-scale fluctuations of the wave velocity. On the one hand, short-scale heterogeneities induce back-scattered echoes whose random interference generate a speckle pattern on the beamformed image. On the other hand, large-scale fluctuations of the wave-velocity can distort the focused wave-fronts, resulting in aberrations on the same image. In this paper, we show how the self-portrait of the wave evolves as a function of the speed-of-sound model. Strikingly, a Gouy phase shift is observed when the speed-of-sound model is optimal. This particularly sensitive feature enables: (i) an optimization of the speed-of-sound model for each pixel of the image; (ii) a local and fine compensation of defocus across the field-of-view, thereby compensating for most aberrations in the image. Experiment in a tissue-mimicking phantom and numerical simulations are first presented to validate our method. It is then applied to in-vivo liver data of a difficult-to-image patient. The speed-of-sound optimization allows an axial compensation of aberrations and a depth-reassignment of each singly-scattered echo to the actual position of the associated scatterer. As distance measurement is often critical for diagnosis, such a wave speed optimization can be crucial for ultrasound but also for any other imaging methods based on the principle of echo-location.

physics.med-ph↗

Pulse-echo ultrasound attenuation tomography

We present the first fully two-dimensional attenuation imaging technique developed for pulse-echo ultrasound systems. Unlike state-of-the-art techniques, which use line-by-line acquisitions, our method uses steered emissions to constrain attenuation values at each location with multiple crossing wave paths, essential to resolve the spatial variations of this tissue property. At every location, we compute normalized cross-correlations between the beamformed images that are obtained from emissions at different steering angles. We demonstrate that their log-amplitudes provide the changes between attenuation-induced amplitude losses undergone by the different incident waves. This allows us to formulate a linear tomographic problem, which we efficiently solve via a Tikhonov-regularized least-squares approach. The performance of our tomography technique is first validated in numerical examples and then experimentally demonstrated in custom-made tissue-mimicking phantoms with inclusions of varying size, echogenicity, and attenuation. We show that this technique is particularly good at resolving lateral variations in tissue attenuation and remains accurate in media with varying echogenicity. Based on a similar principle, this method can be easily combined with computed ultrasound tomography in echo mode (CUTE) for speed-of-sound imaging, paving the way towards a multi-modal ultrasound tomography framework characterizing multiple acoustic tissue properties simultaneously.

physics.med-ph↗

Pulse-echo speed-of-sound imaging using convex probes

Computed ultrasound tomography in echo mode (CUTE) is a new ultrasound (US)-based medical imaging modality with promise for diagnosing various types of disease based on the tissue's speed of sound (SoS). It is developed for conventional pulse-echo US using handheld probes and can thus be implemented in state-of-the-art medical US systems. One promising application is the quantification of the liver fat fraction in fatty liver disease. So far, CUTE was demonstrated using linear array probes where the imaging depth is comparable to the aperture size. For liver imaging, however, convex probes are preferred since they provide a larger penetration depth and a wider view angle allowing to capture a large area of the liver. With the goal of liver imaging in mind, we adapt CUTE to convex probes, with a special focus on discussing strategies that make use of the convex geometry in order to make our implementation computationally efficient. We then demonstrate in an abdominal imaging phantom that accurate quantitative SoS using convex probes is feasible, in spite of the smaller aperture size in relation to the image area compared to linear arrays. A preliminary in vivo result of liver imaging confirms this outcome, but also indicates that deep quantitative imaging in the real liver can be more challenging, probably due to the increased complexity of the tissue compared to phantoms.

physics.med-ph↗