Searcharxiv⌕ Search

arXiv subjects

Negar Sadat Rafiee Tabatabaee

Publications and source records attributed to Negar Sadat Rafiee Tabatabaee.

2 recordsLinked to original sources

Coronary Artery Segmentation and Vessel-Type Classification in X-Ray Angiography

X-ray coronary angiography (XCA) is the clinical reference standard for assessing coronary artery disease, yet quantitative analysis is limited by the difficulty of robust vessel segmentation in routine data. Low contrast, motion, foreshortening, overlap, and catheter confounding degrade segmentation and contribute to domain shift across centers. Reliable segmentation, together with vessel-type labeling, enables vessel-specific coronary analytics and downstream measurements that depend on anatomical localization. From 670 cine sequences (407 subjects), we select a best frame near peak opacification using a low-intensity histogram criterion and apply joint super-resolution and enhancement. We benchmark classical Meijering, Frangi, and Sato vesselness filters under per-image oracle tuning, a single global mean setting, and per-image parameter prediction via Support Vector Regression (SVR). Neural baselines include U-Net, FPN, and a Swin Transformer, trained with coronary-only and merged coronary+catheter supervision. A second stage assigns vessel identity (LAD, LCX, RCA). External evaluation uses the public DCA1 cohort. SVR per-image tuning improves Dice over global means for all classical filters (e.g., Frangi: 0.759 vs. 0.741). Among deep models, FPN attains 0.914+/-0.007 Dice (coronary-only), and merged coronary+catheter labels further improve to 0.931+/-0.006. On DCA1 as a strict external test, Dice drops to 0.798 (coronary-only) and 0.814 (merged), while light in-domain fine-tuning recovers to 0.881+/-0.014 and 0.882+/-0.015. Vessel-type labeling achieves 98.5% accuracy (Dice 0.844) for RCA, 95.4% (0.786) for LAD, and 96.2% (0.794) for LCX. Learned per-image tuning strengthens classical pipelines, while high-resolution FPN models and merged-label supervision improve stability and external transfer with modest adaptation.

cs.CV↗

GraphDerm: Fusing Imaging, Physical Scale, and Metadata in a Population-Graph Classifier for Dermoscopic Lesions

Introduction. Dermoscopy aids melanoma triage, yet image-only AI often ignores patient metadata (age, sex, site) and the physical scale needed for geometric analysis. We present GraphDerm, a population-graph framework that fuses imaging, millimeter-scale calibration, and metadata for multiclass dermoscopic classification, to the best of our knowledge the first ISIC-scale application of GNNs to dermoscopy. Methods. We curate ISIC 2018/2019, synthesize ruler-embedded images with exact masks, and train U-Nets (SE-ResNet-18) for lesion and ruler segmentation. Pixels-per-millimeter are regressed from the ruler-mask two-point correlation via a lightweight 1D-CNN. From lesion masks we compute real-scale descriptors (area, perimeter, radius of gyration). Node features use EfficientNet-B3; edges encode metadata/geometry similarity (fully weighted or thresholded). A spectral GNN performs semi-supervised node classification; an image-only ANN is the baseline. Results. Ruler and lesion segmentation reach Dice 0.904 and 0.908; scale regression attains MAE 1.5 px (RMSE 6.6). The graph attains AUC 0.9812, with a thresholded variant using about 25% of edges preserving AUC 0.9788 (vs. 0.9440 for the image-only baseline); per-class AUCs typically fall in the 0.97-0.99 range. Conclusion. Unifying calibrated scale, lesion geometry, and metadata in a population graph yields substantial gains over image-only pipelines on ISIC-2019. Sparser graphs retain near-optimal accuracy, suggesting efficient deployment. Scale-aware, graph-based AI is a promising direction for dermoscopic decision support; future work will refine learned edge semantics and evaluate on broader curated benchmarks.

cs.CV↗