SearcharxivSearch

arXiv subjects

Nicholas Konz

Publications and source records attributed to Nicholas Konz.

At least 19 recordsLinked to original sources

Curriculum-Aware Interpolate-then-Refine: Learned Physiological Time-Series Imputation under Realistic Missingness

Imputing physiological time series (arterial blood pressure, blood glucose, etc.) is essential for addressing the missingness that pervades clinical data. Yet modern imputation methods perform poorly in this domain: a recent benchmark found that simple linear interpolation outperformed every learned imputer on real-world clinical signals with realistic gaps. We show that this reflects two properties of physiological missingness that generic imputers ignore: gaps may occur when the signal is clinically extreme rather than typical, and gap lengths can easily span orders of magnitude. To this end, we introduce Curriculum-Aware Interpolate-then-Refine (CAIR), a two-stage framework for physiological time-series imputation. Our key motivation is to learn a coarse base curve and then repeatedly correct it toward physiological realism, rather than predict a gap in a single pass. Consequently, CAIR couples a bidirectional-GRU interpolator with a Transformer refiner that corrects its own estimate over three successive passes, trained jointly under a broad, signal-agnostic random-gap curriculum. We evaluate imputers stratified by gap length and missingness mechanism (MCAR, MAR, NMAR) rather than by a single average, and CAIR is the most accurate under every mechanism on continuous glucose monitoring (AI-READI) and arterial pressure in intensive care (MIMIC-III). Its margin over the strongest baseline grows with difficulty, from 9% under MCAR to 19% under value-dependent dropout, where generic learned imputers are weakest. We further show low reconstruction error alone does not recover the burden metrics clinicians act on: interpolants matching CAIR's error fail to preserve those metrics, imputers that recover them are far less accurate, and CAIR alone ranks among the best on both axes.

cs.LG

GALA: Generation-Aware Cross-Modal Alignment for Text-to-Time-Series Synthesis

Synthesizing time series from natural language is emerging as the most expressive form of controllable time series generation. However, existing text-conditioned generators either take caption embeddings frozen from off-the-shelf text encoders, or adapt the encoder end-to-end, letting the denoising loss shape the embeddings only as a by-product. In either case, the conditioning representation is never deliberately matched to the signal modality, leaving it ill-suited to guide generation. We address this by introducing GALA: Generation-Aware cross-modaL Alignment for text conditional time series generation. GALA is a two-stage approach that first contrastively couples a pretrained text encoder with a time-series foundation model into a shared embedding space with both encoders adapted to generation by an auxiliary generative loss, and then freezes the resulting caption embedding to drive a flow-matching generator. On TSFragment-600K, spanning four domains and three fragment lengths, GALA sets a new state of the art, ranking first in 30 of 36 metric columns and reaching an average rank of 1.08/1.08/1.42 at lengths 24/48/96 against 1.92/2.00/1.75 for the strongest baseline. We further find that generator-internal text encoders force a trade-off between fidelity and caption adherence, whereas conditioning on the aligned embedding breaks it: FID, CTTP, and JFTSD all improve at once. Ablating the auxiliary loss degrades FID, CTTP and JFTSD together, it indicates the generative term is a necessary component of the alignment rather than an add-on.

cs.CL

Represent, Then Generate: Multimodal-Conditioned Time-Series Generation under Irregular Missingness

Continuous physiological time series underpin modern clinical monitoring, yet many of the most informative signals are invasive, expensive, or simply unavailable for a given patient. Conditional generation offers a remedy: an absent signal can be synthesized from co-recorded signals and routine clinical variables. Existing generators, however, are built around a single conditioning modality and degrade when forced to handle the heterogeneous, irregularly missing mix of time-variant signals and static covariates seen in practice. We propose ReCoGen (Represent Conditions, then Generate), a two-stage framework that decouples multimodal condition representation from target generation. Stage I trains one masked autoencoder per modality, distilling each time-variant condition into a compact and missingness-tolerant token sequence. Stage II trains a flow-matching generator that fuses these tokens with static conditions to synthesize the target signal. Across three physiological benchmarks, including continuous glucose monitoring on AI-READI and arterial blood pressure generation on MIMIC-III and MIMIC-IV, ReCoGen attains the best downstream utility on all sixteen (dataset, task, metric) settings, surpassing six representative conditional generators; on thirteen of them its utility also reaches or exceeds the utility measured on the real signal, a reference we read as an approximate anchor rather than a ceiling. Ablations trace the gains to the conditioning path: learnable cross-attention over the frozen per-modality encoders, and a dual token-plus-AdaLN route for the static conditions. ReCoGen thus turns routinely collected signals into informative surrogates for invasive or unavailable ones, a step toward less invasive, lower-cost continuous clinical monitoring.

cs.LG

ConceptM$^3$oE: Concept-Guided Multimodal Mixture of Experts for Interpretable Computational Pathology

Healthcare models are transitioning from unimodal prediction toward multimodal reasoning over heterogeneous diagnostic inputs. In computational pathology, for complex tumor subtypes where morphology alone can be challenging to distinguish, pathology reports and molecular measurements may provide additional diagnostic evidence alongside whole-slide images, yet existing models often fail to clarify how diverse signals assemble into recognizable diagnostic concepts. We propose ConceptM$^3$oE (Concept Multimodal MoE), which embeds concept formation directly within interaction-aware mixture-of-experts (MoE) pathways. The architecture decomposes evidence into modality-specific, redundant, and synergistic experts, which are then projected into structured concept bottlenecks mapping latent features to a hierarchy of morphology and biomarker concepts. To prevent the information loss typical of interpretable bottlenecks, we utilize residual pathways within each expert to allow task-relevant signals to flow both through the concepts and directly to the final task prediction, so that high performance is maintained alongside interpretability. Across an institutional pediatric brain tumor cohort and a public glioma cohort, the framework delivers competitive performance to unconstrained models while producing reasoning traces validated by an independent neuropathologist. In data-limited regimes, ConceptM$^3$oE improves limited-data performance, increasing macro-F1 from 56.41% to 66.70% at small training sizes compared to non-concept-informed baselines, while also showing faster training convergence consistent with the regularizing effect of concept learning. This work offers a scalable path toward high-performance medical AI that is inherently verifiable and better aligned with the complex decision-making of clinical practice.

cs.AI

Clinically-Informed Modeling for Pediatric Brain Tumor Classification from Whole-Slide Histopathology Images

Accurate diagnosis of pediatric brain tumors, starting with histopathology, presents unique challenges for deep learning, including severe data scarcity, class imbalance, and fine-grained morphologic overlap across diagnostically distinct subtypes. While pathology foundation models have advanced patch-level representation learning, their effective adaptation to weakly supervised pediatric brain tumor classification under limited data remains underexplored. In this work, we introduce an expert-guided contrastive fine-tuning framework for pediatric brain tumor diagnosis from whole-slide images (WSI). Our approach integrates contrastive learning into slide-level multiple instance learning (MIL) to explicitly regularize the geometry of slide-level representations during downstream fine-tuning. We propose both a general supervised contrastive setting and an expert-guided variant that incorporates clinically informed hard negatives targeting diagnostically confusable subtypes. Through comprehensive experiments on pediatric brain tumor WSI classification under realistic low-sample and class-imbalanced conditions, we demonstrate that contrastive fine-tuning yields measurable improvements in fine-grained diagnostic distinctions. Our experimental analyses reveal complementary strengths across different contrastive strategies, with expert-guided hard negatives promoting more compact intra-class representations and improved inter-class separation. This work highlights the importance of explicitly shaping slide-level representations for robust fine-grained classification in data-scarce pediatric pathology settings.

cs.CV

PathMoE: Interpretable Multimodal Interaction Experts for Pediatric Brain Tumor Classification

Accurate classification of pediatric central nervous system tumors remains challenging due to histological complexity and limited training data. While pathology foundation models have advanced whole-slide image (WSI) analysis, they often fail to leverage the rich, complementary information found in clinical text and tissue microarchitecture. To this end, we propose PathMoE, an interpretable multimodal framework that integrates H\&E slides, pathology reports, and nuclei-level cell graphs via an interaction-aware mixture-of-experts architecture built on state-of-the-art foundation models for each modality. By training specialized experts to capture modality uniqueness, redundancy, and synergy, PathMoE employs an input-dependent gating mechanism that dynamically weights these interactions, providing sample-level interpretability. We evaluate our framework on two dataset-specific classification tasks on an internal pediatric brain tumor dataset (PBT) and external TCGA datasets. PathMoE improves macro-F1 from 0.762 to 0.799 (+0.037) on PBT when integrating WSI, text, and graph modalities; on TCGA, augmenting WSI with graph knowledge improves macro-F1 from 0.668 to 0.709 (+0.041). These results demonstrate significant performance gains over state-of-the-art image-only baselines while revealing the specific modality interactions driving individual predictions. This interpretability is particularly critical for rare tumor subtypes, where transparent model reasoning is essential for clinical trust and diagnostic validation.

cs.CV

Are Vision Foundation Models Ready for Out-of-the-Box Medical Image Registration?

Foundation models, pre-trained on large image datasets and capable of capturing rich feature representations, have recently shown potential for zero-shot image registration. However, their performance has mostly been tested in the context of rigid or less complex structures, such as the brain or abdominal organs, and it remains unclear whether these models can handle more challenging, deformable anatomy. Breast MRI registration is particularly difficult due to significant anatomical variation between patients, deformation caused by patient positioning, and the presence of thin and complex internal structure of fibroglandular tissue, where accurate alignment is crucial. Whether foundation model-based registration algorithms can address this level of complexity remains an open question. In this study, we provide a comprehensive evaluation of foundation model-based registration algorithms for breast MRI. We assess five pre-trained encoders, including DINO-v2, SAM, MedSAM, SSLSAM, and MedCLIP, across four key breast registration tasks that capture variations in different years and dates, sequences, modalities, and patient disease status (lesion versus no lesion). Our results show that foundation model-based algorithms such as SAM outperform traditional registration baselines for overall breast alignment, especially under large domain shifts, but struggle with capturing fine details of fibroglandular tissue. Interestingly, additional pre-training or fine-tuning on medical or breast-specific images in MedSAM and SSLSAM, does not improve registration performance and may even decrease it in some cases. Further work is needed to understand how domain-specific training influences registration and to explore targeted strategies that improve both global alignment and fine structure accuracy. We also publicly release our code at \href{https://github.com/mazurowski-lab/Foundation-based-reg}{Github}.

eess.IV

SegmentAnyMuscle: A universal muscle segmentation model across different locations in MRI

The quantity and quality of muscles are increasingly recognized as important predictors of health outcomes. While MRI offers a valuable modality for such assessments, obtaining precise quantitative measurements of musculature remains challenging. This study aimed to develop a publicly available model for muscle segmentation in MRIs and demonstrate its applicability across various anatomical locations and imaging sequences. A total of 362 MRIs from 160 patients at a single tertiary center (Duke University Health System, 2016-2020) were included, with 316 MRIs from 114 patients used for model development. The model was tested on two separate sets: one with 28 MRIs representing common sequence types, achieving an average Dice Similarity Coefficient (DSC) of 88.45%, and another with 18 MRIs featuring less frequent sequences and abnormalities such as muscular atrophy, hardware, and significant noise, achieving 86.21% DSC. These results demonstrate the feasibility of a fully automated deep learning algorithm for segmenting muscles on MRI across diverse settings. The public release of this model enables consistent, reproducible research into the relationship between musculature and health.

eess.SP

MRI-CORE: A Foundation Model for Magnetic Resonance Imaging

The widespread use of Magnetic Resonance Imaging (MRI) in combination with deep learning shows promise for many high-impact automated diagnostic and prognostic tools. However, training new models requires large amounts of labeled data, a challenge due to high cost of precise annotations and data privacy. To address this issue, we introduce the MRI-CORE, a vision foundation model trained using more than 6 million slices from over 110 thousand MRI volumes across 18 body locations. Our experiments show notable improvements in performance over state-of-the-art methods in 13 data-restricted segmentation tasks, as well as in image classification, and zero-shot segmentation, showing the strong potential of MRI-CORE to enable data-efficient development of artificial intelligence models. We also present data on which strategies yield most useful foundation models and a novel analysis relating similarity between pre-training and downstream task data with transfer learning performance. Our model is publicly available with a permissive license.

eess.IV

GuidedMorph: Two-Stage Deformable Registration for Breast MRI

Accurately registering breast MR images from different time points enables the alignment of anatomical structures and tracking of tumor progression, supporting more effective breast cancer detection, diagnosis, and treatment planning. However, the complexity of dense tissue and its highly non-rigid nature pose challenges for conventional registration methods, which primarily focus on aligning general structures while overlooking intricate internal details. To address this, we propose \textbf{GuidedMorph}, a novel two-stage registration framework designed to better align dense tissue. In addition to a single-scale network for global structure alignment, we introduce a framework that utilizes dense tissue information to track breast movement. The learned transformation fields are fused by introducing the Dual Spatial Transformer Network (DSTN), improving overall alignment accuracy. A novel warping method based on the Euclidean distance transform (EDT) is also proposed to accurately warp the registered dense tissue and breast masks, preserving fine structural details during deformation. The framework supports paradigms that require external segmentation models and with image data only. It also operates effectively with the VoxelMorph and TransMorph backbones, offering a versatile solution for breast registration. We validate our method on ISPY2 and internal dataset, demonstrating superior performance in dense tissue, overall breast alignment, and breast structural similarity index measure (SSIM), with notable improvements by over 13.01% in dense tissue Dice, 3.13% in breast Dice, and 1.21% in breast SSIM compared to the best learning-based baseline.

eess.IV

Accelerating Volumetric Medical Image Annotation via Short-Long Memory SAM 2

Manual annotation of volumetric medical images, such as magnetic resonance imaging (MRI) and computed tomography (CT), is a labor-intensive and time-consuming process. Recent advancements in foundation models for video object segmentation, such as Segment Anything Model 2 (SAM 2), offer a potential opportunity to significantly speed up the annotation process by manually annotating one or a few slices and then propagating target masks across the entire volume. However, the performance of SAM 2 in this context varies. Our experiments show that relying on a single memory bank and attention module is prone to error propagation, particularly at boundary regions where the target is present in the previous slice but absent in the current one. To address this problem, we propose Short-Long Memory SAM 2 (SLM-SAM 2), a novel architecture that integrates distinct short-term and long-term memory banks with separate attention modules to improve segmentation accuracy. We evaluate SLM-SAM 2 on four public datasets covering organs, bones, and muscles across MRI, CT, and ultrasound videos. We show that the proposed method markedly outperforms the default SAM 2, achieving an average Dice Similarity Coefficient improvement of 0.14 and 0.10 in the scenarios when 5 volumes and 1 volume are available for the initial adaptation, respectively. SLM-SAM 2 also exhibits stronger resistance to over-propagation, reducing the time required to correct propagated masks by 60.575% per volume compared to SAM 2, making a notable step toward more accurate automated annotation of medical images for segmentation model development.

eess.IV

Quantifying the Limits of Segmentation Foundation Models: Modeling Challenges in Segmenting Tree-Like and Low-Contrast Objects

Image segmentation foundation models (SFMs) like Segment Anything Model (SAM) have achieved impressive zero-shot and interactive segmentation across diverse domains. However, they struggle to segment objects with certain structures, particularly those with dense, tree-like morphology and low textural contrast from their surroundings. These failure modes are crucial for understanding the limitations of SFMs in real-world applications. To systematically study this issue, we introduce interpretable metrics quantifying object tree-likeness and textural separability. On carefully controlled synthetic experiments and real-world datasets, we show that SFM performance (\eg, SAM, SAM 2, HQ-SAM) noticeably correlates with these factors. We attribute these failures to SFMs misinterpreting local structure as global texture, resulting in over-segmentation or difficulty distinguishing objects from similar backgrounds. Notably, targeted fine-tuning fails to resolve this issue, indicating a fundamental limitation. Our study provides the first quantitative framework for modeling the behavior of SFMs on challenging structures, offering interpretable insights into their segmentation capabilities.

cs.CV

Fr\'echet Radiomic Distance (FRD): A Versatile Metric for Comparing Medical Imaging Datasets

Determining whether two sets of images belong to the same or different distributions or domains is a crucial task in modern medical image analysis and deep learning; for example, to evaluate the output quality of image generative models. Currently, metrics used for this task either rely on the (potentially biased) choice of some downstream task, such as segmentation, or adopt task-independent perceptual metrics (e.g., Fr\'echet Inception Distance/FID) from natural imaging, which we show insufficiently capture anatomical features. To this end, we introduce a new perceptual metric tailored for medical images, FRD (Fr\'echet Radiomic Distance), which utilizes standardized, clinically meaningful, and interpretable image features. We show that FRD is superior to other image distribution metrics for a range of medical imaging applications, including out-of-domain (OOD) detection, the evaluation of image-to-image translation (by correlating more with downstream task performance as well as anatomical consistency and realism), and the evaluation of unconditional image generation. Moreover, FRD offers additional benefits such as stability and computational efficiency at low sample sizes, sensitivity to image corruptions and adversarial attacks, feature interpretability, and correlation with radiologist-perceived image quality. Additionally, we address key gaps in the literature by presenting an extensive framework for the multifaceted evaluation of image similarity metrics in medical imaging -- including the first large-scale comparative study of generative models for medical image translation -- and release an accessible codebase to facilitate future research. Our results are supported by thorough experiments spanning a variety of datasets, modalities, and downstream tasks, highlighting the broad potential of FRD for medical image analysis.

cs.CV

The Impact of Scanner Domain Shift on Deep Learning Performance in Medical Imaging: an Experimental Study

Purpose: Medical images acquired using different scanners and protocols can differ substantially in their appearance. This phenomenon, scanner domain shift, can result in a drop in the performance of deep neural networks which are trained on data acquired by one scanner and tested on another. This significant practical issue is well-acknowledged, however, no systematic study of the issue is available across different modalities and diagnostic tasks. Materials and Methods: In this paper, we present a broad experimental study evaluating the impact of scanner domain shift on convolutional neural network performance for different automated diagnostic tasks. We evaluate this phenomenon in common radiological modalities, including X-ray, CT, and MRI. Results: We find that network performance on data from a different scanner is almost always worse than on same-scanner data, and we quantify the degree of performance drop across different datasets. Notably, we find that this drop is most severe for MRI, moderate for X-ray, and quite small for CT, on average, which we attribute to the standardized nature of CT acquisition systems which is not present in MRI or X-ray. We also study how injecting varying amounts of target domain data into the training set, as well as adding noise to the training data, helps with generalization. Conclusion: Our results provide extensive experimental evidence and quantification of the extent of performance drop caused by scanner domain shift in deep learning across different modalities, with the goal of guiding the future development of robust deep learning models for medical image analysis.

eess.IV

Pre-processing and Compression: Understanding Hidden Representation Refinement Across Imaging Domains via Intrinsic Dimension

In recent years, there has been interest in how geometric properties such as intrinsic dimension (ID) of a neural network's hidden representations change through its layers, and how such properties are predictive of important model behavior such as generalization ability. However, evidence has begun to emerge that such behavior can change significantly depending on the domain of the network's training data, such as natural versus medical images. Here, we further this inquiry by exploring how the ID of a network's learned representations changes through its layers, in essence, characterizing how the network successively refines the information content of input data to be used for predictions. Analyzing eleven natural and medical image datasets across six network architectures, we find that how ID changes through the network differs noticeably between natural and medical image models. Specifically, medical image models peak in representation ID earlier in the network, implying a difference in the image features and their abstractness that are typically used for downstream tasks in these domains. Additionally, we discover a strong correlation of this peak representation ID with the ID of the data in its input space, implying that the intrinsic information content of a model's learned representations is guided by that of the data it was trained on. Overall, our findings emphasize notable discrepancies in network behavior between natural and non-natural imaging domains regarding hidden representation information content, and provide further insights into how a network's learned features are shaped by its training data.

cs.CV

Rethinking Perceptual Metrics for Medical Image Translation

Modern medical image translation methods use generative models for tasks such as the conversion of CT images to MRI. Evaluating these methods typically relies on some chosen downstream task in the target domain, such as segmentation. On the other hand, task-agnostic metrics are attractive, such as the network feature-based perceptual metrics (e.g., FID) that are common to image translation in general computer vision. In this paper, we investigate evaluation metrics for medical image translation on two medical image translation tasks (GE breast MRI to Siemens breast MRI and lumbar spine MRI to CT), tested on various state-of-the-art translation methods. We show that perceptual metrics do not generally correlate with segmentation metrics due to them extending poorly to the anatomical constraints of this sub-field, with FID being especially inconsistent. However, we find that the lesser-used pixel-level SWD metric may be useful for subtle intra-modality translation. Our results demonstrate the need for further research into helpful metrics for medical image translation.

eess.IV

ContourDiff: Unpaired Medical Image Translation with Structural Consistency

Accurately translating medical images between different modalities, such as Computed Tomography (CT) to Magnetic Resonance Imaging (MRI), has numerous downstream clinical and machine learning applications. While several methods have been proposed to achieve this, they often prioritize perceptual quality with respect to output domain features over preserving anatomical fidelity. However, maintaining anatomy during translation is essential for many tasks, e.g., when leveraging masks from the input domain to develop a segmentation model with images translated to the output domain. To address these challenges, we propose ContourDiff with Spatially Coherent Guided Diffusion (SCGD), a novel framework that leverages domain-invariant anatomical contour representations of images. These representations are simple to extract from images, yet form precise spatial constraints on their anatomical content. We introduce a diffusion model that converts contour representations of images from arbitrary input domains into images in the output domain of interest. By applying the contour as a constraint at every diffusion sampling step, we ensure the preservation of anatomical content. We evaluate our method on challenging lumbar spine and hip-and-thigh CT-to-MRI translation tasks, via (1) the performance of segmentation models trained on translated images applied to real MRIs, and (2) the foreground FID and KID of translated images with respect to real MRIs. Our method outperforms other unpaired image translation methods by a significant margin across almost all metrics and scenarios. Moreover, it achieves this without the need to access any input domain information during training and we further verify its zero-shot capability, showing that a model trained on one anatomical region can be directly applied to unseen regions without retraining (GitHub: https://github.com/mazurowski-lab/ContourDiff).

eess.IV

Medical Image Segmentation with InTEnt: Integrated Entropy Weighting for Single Image Test-Time Adaptation

Test-time adaptation (TTA) refers to adapting a trained model to a new domain during testing. Existing TTA techniques rely on having multiple test images from the same domain, yet this may be impractical in real-world applications such as medical imaging, where data acquisition is expensive and imaging conditions vary frequently. Here, we approach such a task, of adapting a medical image segmentation model with only a single unlabeled test image. Most TTA approaches, which directly minimize the entropy of predictions, fail to improve performance significantly in this setting, in which we also observe the choice of batch normalization (BN) layer statistics to be a highly important yet unstable factor due to only having a single test domain example. To overcome this, we propose to instead integrate over predictions made with various estimates of target domain statistics between the training and test statistics, weighted based on their entropy statistics. Our method, validated on 24 source/target domain splits across 3 medical image datasets surpasses the leading method by 2.9% Dice coefficient on average.

cs.CV