Publications and source records attributed to Nick Scholand.

10 recordsLinked to original sources

Dynamic transitions for fast joint acquisition and reconstruction of CEST-Rex and T1

Purpose: This work proposes a method for the simultaneous estimation of the exchange-dependent relaxation rate Rex and the longitudinal relaxation time T1 from a single acquisition. Methods: A novel acquisition scheme was developed that combines CEST saturation with an inversion pulse and a Look-Locker readout to capture the magnetization evolution starting from the inverse transient Z-spectrum. The corresponding signal model, derived from the Bloch-McConnell equations, describes both the transient Z-spectrum and the Look-Locker dynamics. A model-based reconstruction approach is employed to jointly estimate Rex and T1. The proposed method was validated using a numerical phantom and benchmarked against conventional CEST and Look-Locker T1 mapping in phantom and in vivo on a clinical 3T scanner. Results: The joint estimation approach demonstrated strong agreement with ground truth and conventional methods across a wide range of T1 and CEST parameters. The acquisition time was reduced by 20-30% compared to standard CEST protocols, while providing higher signal-to-noise ratio (SNR) in parameter maps. Conclusion: The proposed technique enables robust and efficient simultaneous quantification of CEST Rex and T1 in a single acquisition. It improves parameter map quality and reduces scan time, making it suitable for both phantom and in vivo imaging across a wide range of physiological conditions.

physics.med-ph

Rational Approximation of Golden Angles: Accelerated Reconstructions for Radial MRI

Purpose: To develop a generic radial sampling scheme that combines the advantages of golden ratio sampling with simplicity of equidistant angular patterns. The irrational angle between consecutive spokes in golden ratio based sampling schemes enables a flexible retrospective choice of temporal resolution, while preserving good coverage of k-space for each individual bin. Nevertheless, irrational increments prohibit precomputation of the point-spread function (PSF), can lead to numerical problems, and require more complex processing steps. To avoid these problems, a new sampling scheme based on a rational approximation of golden angles (RAGA) is developed. Methods: The theoretical properties of RAGA sampling are mathematically derived. Sidelobe-to-peak ratios (SPR) are numerically computed and compared to the corresponding golden ratio sampling schemes. The sampling scheme is implemented in the BART toolbox and in a radial gradient-echo sequence. Feasibility is shown for quantitative imaging in a phantom and a cardiac scan of a healthy volunteer. Results: RAGA sampling can accurately approximate golden ratio sampling and has almost identical PSF and SPR. In contrast to golden ratio sampling, each frame can be reconstructed with the same equidistant trajectory using different sampling masks, and the angle of each acquired spoke can be encoded as a small index, which simplifies processing of the acquired data. Conclusion: RAGA sampling provides the advantages of golden ratio sampling while simplifying data processing, rendering it a valuable tool for dynamic and quantitative MRI.

physics.med-ph

Model-Based Reconstruction for Joint Estimation of $T_{1}$, $R_{2}^{*}$ and $B_{0}$ Field Maps Using Single-Shot Inversion-Recovery Multi-Echo Radial FLASH

Purpose: To develop a model-based nonlinear reconstruction for simultaneous water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or fat fraction (FF) mapping using single-shot inversion-recovery (IR) multi-echo radial FLASH. Methods: The proposed model-based reconstruction jointly estimates water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF maps, as well as a set of coil sensitivities directly from $k$-space obtained with a single-shot IR multi-echo radial FLASH sequence using blip gradients across echoes. Joint sparsity constraints are exploited on multiple quantitative maps to improve precision. Validations are performed on numerical and NIST phantoms and with in vivo studies of the human brain and liver at 3 T. Results: Numerical phantom studies demonstrate the effects of fat signals in $T_{1}$ estimation and confirm good quantitative accuracy of the proposed method for all parameter maps. NIST phantom results confirm good quantitative $T_{1}$ and $R_{2}^{*}$ accuracy in comparison to Cartesian references. Apart from good quantitative accuracy and precision for multiple parameter maps, in vivo studies show improved image details utilizing the proposed joint estimation. The proposed method can achieve simultaneous water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF mapping for brain (0.81 $\times$ 0.81 $\times$ 5 mm$^{3}$) and liver (1.6 $\times$ 1.6 $\times$ 6 mm$^{3}$) imaging within four seconds. Conclusion: The proposed model-based nonlinear reconstruction, in combination with a single-shot IR multi-echo radial FLASH acquisition, enables joint estimation of accurate water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF maps within four seconds. The present work is of potential value for specific clinical applications.

physics.med-ph

Quantitative Magnetic Resonance Imaging by Nonlinear Inversion of the Bloch Equations

Purpose: Development of a generic model-based reconstruction framework for multi-parametric quantitative MRI that can be used with data from different pulse sequences. Methods: Generic nonlinear model-based reconstruction for quantitative MRI estimates parametric maps directly from the acquired k-space by numerical optimization. This requires numerically accurate and efficient methods to solve the Bloch equations and their partial derivatives. In this work, we combine direct sensitivity analysis and pre-computed state-transition matrices into a generic framework for calibrationless model-based reconstruction that can be applied to different pulse sequences. As a proof-of-concept, the method is implemented and validated for quantitative $T_1$ and $T_2$ mapping with single-shot inversion-recovery (IR) FLASH and IR bSSFP sequences in simulations, phantoms, and the human brain. Results: The direct sensitivity analysis enables a highly accurate and numerically stable calculation of the derivatives. The state-transition matrices efficiently exploit repeating patterns in pulse sequences, speeding up the calculation by a factor of 10 for the examples considered in this work, while preserving the accuracy of native ODE solvers. The generic model-based method reproduces quantitative results of previous model-based reconstructions based on the known analytical solutions for radial IR FLASH. For IR bSFFP it produces accurate $T_1$ and $T_2$ maps for the NIST phantom in numerical simulations and experiments. Feasibility is also shown for human brain, although results are affected by magnetization transfer effects. Conclusion: By developing efficient tools for numerical optimizations using the Bloch equations as forward model, this work enables generic model-based reconstruction for quantitative MRI.

physics.med-ph

Free-Breathing Myocardial T1 Mapping using Inversion-Recovery Radial FLASH and Motion-Resolved Model-Based Reconstruction

Purpose: To develop a free-breathing myocardial T1 mapping technique using inversion-recovery (IR) radial fast low-angle shot (FLASH) and calibrationless motion-resolved model-based reconstruction. Methods: Free-running (free-breathing, retrospective cardiac gating) IR radial FLASH is used for data acquisition at 3T. First, to reduce the waiting time between inversions, an analytical formula is derived that takes the incomplete T1 recovery into account for an accurate T1 calculation. Second, the respiratory motion signal is estimated from the k-space center of the contrast varying acquisition using an adapted singular spectrum analysis (SSA-FARY) technique. Third, a motion-resolved model-based reconstruction is used to estimate both parameter and coil sensitivity maps directly from the sorted k-space data. Thus, spatiotemporal total variation, in addition to the spatial sparsity constraints, can be directly applied to the parameter maps. Validations are performed on an experimental phantom, eleven human subjects, and a young landrace pig with myocardial infarction. Results: In comparison to an IR spin-echo reference, phantom results confirm good T1 accuracy when reducing the waiting time from five seconds to one second using the new correction. The motion-resolved model-based reconstruction further improves precision compared to the spatial regularization-only reconstruction. Aside from showing that a reliable respiratory motion signal can be estimated using modified SSA-FARY, in vivo studies demonstrate that dynamic myocardial T1 maps can be obtained within two minutes with good precision and repeatability. Conclusion: Motion-resolved myocardial T1 mapping during free-breathing with good accuracy, precision and repeatability can be achieved by combining inversion-recovery radial FLASH, self-gating and a calibrationless motion-resolved model-based reconstruction.

physics.med-ph

Free-Breathing Liver Fat, $R_2^*$ and $B_0$ Field Mapping Using Multi-Echo Radial FLASH and Regularized Model-based Reconstruction

This work introduced a stack-of-radial multi-echo asymmetric-echo MRI sequence for free-breathing liver volumetric acquisition. Regularized model-based reconstruction was implemented in Berkeley Advanced Reconstruction Toolbox (BART) to jointly estimate all physical parameter maps (water, fat, R2*, and B0 field inhomogeneity maps) and coil sensitivity maps from self-gated k-space data. Specifically, locally low rank and temporal total variation regularization were employed directly on physical parameter maps. The proposed free-breathing radial technique was tested on a water/fat & iron phantom, a young volunteer, and obesity/diabetes/hepatic steatosis patients. Quantitative fat fraction and R2* accuracy were confirmed by comparing our technique with the reference breath-hold Cartesian scan. The multi-echo radial sampling sequence achieves fast k-space coverage and is robust to motion. Moreover, the proposed motion-resolved model-based reconstruction allows for free-breathing liver fat and R2* quantification in multiple motion states. Overall, our proposed technique offers a convenient tool for non-invasive liver assessment with no breath holding requirement.

physics.med-ph

Physics-based Reconstruction Methods for Magnetic Resonance Imaging

Conventional Magnetic Resonance Imaging (MRI) is hampered by long scan times and only qualitative image contrasts that prohibit a direct comparison between different systems. To address these limitations, model-based reconstructions explicitly model the physical laws that govern the MRI signal generation. By formulating image reconstruction as an inverse problem, quantitative maps of the underlying physical parameters can then be extracted directly from efficiently acquired k-space signals without intermediate image reconstruction -- addressing both shortcomings of conventional MRI at the same time. This review will discuss basic concepts of model-based reconstructions and report about our experience in developing several model-based methods over the last decade using selected examples that are provided complete with data and code.

eess.IV

Model-Based Reconstruction for Simultaneous Multi-Slice T1 Mapping using Single-Shot Inversion-Recovery Radial FLASH

Purpose: To develop a single-shot multi-slice T1 mapping method by combing simultaneous multi-slice (SMS) excitations, single-shot inversion-recovery (IR) radial fast low-angle shot (FLASH) and a nonlinear model-based reconstruction method. Methods: SMS excitations are combined with a single-shot IR radial FLASH sequence for data acquisition. A previously developed single-slice calibrationless model-based reconstruction is extended to SMS, formulating the estimation of parameter maps and coil sensitivities from all slices as a single nonlinear inverse problem. Joint-sparsity constraints are further applied to the parameter maps to improve T1 precision. Validations of the proposed method are performed for a phantom and for the human brain and liver in six healthy adult subjects. Results: Phantom results confirm good T1 accuracy and precision of the simultaneously acquired multi-slice T1 maps in comparison to single-slice references. In-vivo human brain studies demonstrate the better performance of SMS acquisitions compared to the conventional spoke-interleaved multi-slice acquisition using model-based reconstruction. Apart from good accuracy and precision, the results of six healthy subjects in both brain and abdominal studies confirm good repeatability between scan and re-scans. The proposed method can simultaneously acquire T1 maps for five slices of a human brain ($0.75 \times 0.75 \times 5$ mm$^3$) or three slices of the abdomen ($1.25 \times 1.25 \times 6$ mm$^3$) within four seconds. Conclusion: The IR SMS radial FLASH acquisition together with a non-linear model-based reconstruction enable rapid high-resolution multi-slice T1 mapping with good accuracy, precision, and repeatability.

physics.med-ph

Cardiac and Respiratory Self-Gating in Radial MRI using an Adapted Singular Spectrum Analysis (SSA-FARY)

Cardiac Magnetic Resonance Imaging (MRI) is time-consuming and error-prone. To ease the patient's burden and to increase the efficiency and robustness of cardiac exams, interest in methods based on continuous steady-state acquisition and self-gating has been growing in recent years. Self-gating methods extract the cardiac and respiratory signals from the measurement data and then retrospectively sort the data into cardiac and respiratory phases. Repeated breathholds and synchronization with the heart beat using some external device as required in conventional MRI are then not necessary. In this work, we introduce a novel self-gating method for radially acquired data based on a dimensionality reduction technique for time-series analysis (SSA-FARY). Building on Singular Spectrum Analysis, a zero-padded, time-delayed embedding of the auto-calibration data is analyzed using Principle Component Analysis. We demonstrate the basic functionality of SSA-FARY using numerical simulations and apply it to in-vivo cardiac radial single-slice bSSFP and Simultaneous Multi-Slice radiofrequency-spoiled gradient-echo measurements, as well as to Stack-of-Stars bSSFP measurements. SSA-FARY reliably detects the cardiac and respiratory motion and separates it from noise. We utilize the generated signals for high-dimensional image reconstruction using parallel imaging and compressed sensing with in-plane wavelet and (spatio-)temporal total-variation regularization.

physics.med-ph

Model-Based Reconstruction for Quantitative MRI using the Bloch Equations

In this work a generic model-based reconstruction for the quantification of relaxation parameters is developed. In contrast to previous approaches that rely on simplified models derived from the Bloch equations, this work includes the Bloch equations directly into the reconstruction. Therefore, non-linear calibrationless parallel imaging is combined with a generic Runge-Kutta 5(4) based forward operator to simulate spin dynamics described by arbitrary sequences. Gradients are determined by using a sensitivity analysis and solving the resulting ordinary differential equations parallel to the signal simulation. Based on this formulation an IRGNM-FISTA algorithm is used to estimate quantitative maps for $T_1$, $T_2$, $M_0$, and the coil profiles $c_N$ from fully-sampled multi-inversion and golden-angle single-shot inversion-recovery radial bSSFP measurement with a custom-built $T_1$-$T_2$ phantom.

physics.med-ph