SearcharxivSearch

arXiv subjects

Nicolas Kempf

Publications and source records attributed to Nicolas Kempf.

4 recordsLinked to original sources

Overcoming the limitations of NMR Field Probes: A Novel Integrated Sensor Utilizing Pre-Polarization for (Ultra) Low Field MRI

Access to magnetic resonance imaging (MRI) remains severely limited in low- and middle-income countries, especially in sub-Saharan Africa, despite rising rates of non-communicable diseases. Low-field MRI presents an affordable, locally developable diagnostic solution, but its performance is constrained by magnetic field instability. We present a novel NMR field probe designed to overcome these challenges using a rapid non-adiabatic switch-off of a pre-polarization field resulting in precessing spin magnetization. Achieved by first use of high-voltage silicon carbide transistors operating in controlled avalanche breakdown, it measures the Larmor frequency without prior field knowledge, unlike conventional probes. This capability is crucial during magnet development with often unknown fields, allowing early detection of magnet issues, and offering an urgently needed tool for magnet design and image-quality improvement. Validated from 1 mT to 45 mT (up to 1,000 times stronger than similar systems) its low-cost, modular design supports replication, upgrades, and enhanced field control, helping expand global MRI access.

physics.med-ph

Indirect Zero Field NMR Spectroscopy

This study pioneers the two-field correlation spectroscopy (COSY) in zero to ultralow field (ZULF) liquid state NMR, employing hyperpolarized [1-$^{13}$C]pyruvate as a model system. We demonstrate the successful integration of signal amplification by reversible exchange (SABRE) for hyperpolarization, enabling the detection of ZULF COSY spectra with increased sensitivity. The use of field cycling allows the acquisition of two-field COSY spectra at varying magnetic field strengths, including zero-field conditions. This enables insight into both J-coupling and Zeeman-dominated regimes benefiting from ULF field observation sensitivity and mitigation of low-frequency noise by conducting readout at higher fields (>5 $\mu$T). Our study explores the effects of polarization transfer, apodization techniques, and the potential for further application of ZULF NMR in chemical analysis exemplified for three X-nuclei and three corresponding molecules: [1-$^{13}$C]pyruvate, [$^{15}$N]acetonitrile and [3-$^{19}$F]pyridine. These findings pave the way for more sensitive and cost-effective NMR spectroscopy in low-field regimes.

physics.med-ph

LIGHT-SABRE hyperpolarizes 1-^{13}C-pyruvate continuously, without magnetic field cycling

Nuclear spin hyperpolarization enables real-time observation of metabolism and intermolecular interactions in vivo. 1-13C-Pyruvate is the leading hyperpolarized tracer currently under evaluation in several clinical trials as a promising molecular imaging agent. Still, the quest for a simple, fast, and efficient hyperpolarization technique is ongoing. Here, we describe that continuous, weak irradiation in the audio-frequency range of the 13C spin at 121 {\mu}T magnetic field (\sim twiceEarth\apos s field) enables spin order transfer from parahydrogen to 13C magnetization of 1-13C-pyruvate. These so-called LIGHT-SABRE pulses couple nuclear spin states of parahydrogen and pyruvate via the J-coupling network of reversibly exchanging Ir-complexes. Using \sim 100% parahydrogen at ambient pressure, we polarized 51 mM of 1-13C-pyruvate in the presence of 5.1 mM Ir-complex continuously and repeatedly to a polarization of 1.1% averaged over free and catalyst-bound pyruvate. The experiments were conducted at -8{\deg}C), where almost exclusively bound pyruvate was observed, corresponding to an estimated 11% polarization on bound pyruvate. The obtained hyperpolarization levels closely match those obtained via SABRE-SHEATH under otherwise identical conditions. The creation of three different types of spin orders was observed: transverse 13C magnetization along the applied magnetic field, 13C z-magnetization along the main field B_0, and 13C-1H zz-spin-order. With a superconducting quantum interference device (SQUID) for detection, we found that the generated spin orders result from tiny 1H-13C J-coupling interactions, which are not visible even with our narrow linewidth below 0.3 Hz.

physics.chem-ph

Coherent evolution of signal amplification by reversible exchange in two alternating fields (alt-SABRE)

Parahydrogen (pH2) is a convenient and cost efficient source for magnetic resonance signal enhancement. Transient interaction of pH2 with a metal organic complex in a signal amplification by reversible exchange (SABRE) experiment enabled more than 10% polarization for some 15N molecules. Here, we analyzed a variant of SABRE, consisting of an outer magnetic field alternating between a low field of ~1 \muT, where a polarization transfer takes place, and a higher field >50 \muT (alt-SABRE). We found effects of both of these fields on amplitude and the frequency of polarization transfer. Deviation of a lower magnetic field from a "perfect" condition of level anti-crossing increases the frequency of polarization transfer that can be exploited for polarization of short-lived transient SABRE complexes i.e. some substrates. Moreover, the coherences responsible for polarization transfer at a lower field persisted during magnetic field variation and continued their spin evolution at higher field with a frequency of 2.5 kHz at 54 \muT. The latter should be taken into consideration for an efficient alt-SABRE.

physics.chem-ph