SearcharxivSearch

arXiv subjects

Nicolas Verrier

Publications and source records attributed to Nicolas Verrier.

17 recordsLinked to original sources

Co-design of an in-line holographic microscope with enhanced axial resolution: selective filtering digital holography

Common-path digital in-line holography is considered as a valuable 3D diagnostic techniques for a wide range of applications. This configuration is cost effective and relatively immune to variation in the experimental environment. Nevertheless, due to its common-path geometry, the signal to noise-ratio of the acquired hologram is weak as most of the detector (i.e. CCD/CMOS sensor) dynamics is occupied by the reference field signal, whose energy is orders of magnitude higher than the field scattered by the imaged object. As it is intrinsically impossible to modify the ratio of energy of reference to the object field, we propose a co-design approach (Optics/Data Processing) to tackle this issue. The reference to object field ratio is adjusted by adding a 4-f device to a conventional in-line holographic setup, making it possible to reduce the weight of the reference field while keeping the object field almost constant. Theoretical analysis of the Cràmer-Rao lower bounds of the corresponding imaging model illustrate the advantages of this approach. These lower bounds can be asymptotically reached using a parametric inverse problems reconstruction. This implementation results in a 60 % gain in axial localization accuracy (for of 100 $μ$m diameter spherical objects) compared to a classical in-line holography setup .

physics.ins-det

High numerical aperture holographic microscopy reconstruction with extended z range

An holographic microscopy reconstruction method compatible with high numerical aperture microscope objective (MO) up to NA=1.4 is proposed. After off axis and reference field curvature corrections, and after selection of the +1 grating order holographic image, a phase mask that transforms the optical elements of the holographic setup into an afocal device is applied in the camera plane. The reconstruction is then made by the angular spectrum method. The field is first propagated in the image half space from the camera to the afocal image of the MO optimal plane (plane for which MO has been designed) by using a quadratic kernel. The field is then propagated from the MO optimal plane to the object with the exact kernel. Calibration of the reconstruction is made by imaging a calibrated object like an USAF resolution target for different positions along $z$. Once the calibration is done, the reconstruction can be made with an object located in any plane $z$. The reconstruction method has been validated experimentally with an USAF target imaged with a NA=1.4 microscope objective. Near-optimal resolution is obtained over an extended range ($\pm 50~μ$m) of $z$ locations.

physics.optics

Holographic vibrometry: Full field holographic vibrometry at ultimate limits

Heterodyne holography is an extremely versatile and powerful holographic technique that is able to fully control the amplitude, phase and frequency of both the illumination and holographic reference beams. Applied to vibration analysis, this technique is able to detect the signal of the carrier or the one of any vibration sideband. A complete analysis of the vibration signal can thus be made, and 2D map of the vibration amplitude and phase in all points of the surface of the vibrating object can be obtained. Since the sensitivity is limited by shot noise, extremely low vibration amplitude (\textless{} 0.01 nm) can be studied.

physics.optics

3D tracking the Brownian motion of colloidal particles using digital holographic microscopy and joint reconstruction

In-line digital holography is a valuable tool for sizing, locating and tracking micro- or nano-objects in a volume. When a parametric imaging model is available, Inverse Problems approaches provide a straightforward estimate of the object parameters by fitting data with the model, thereby allowing accurate reconstruction. As recently proposed and demonstrated, combining pixel super-resolution techniques with Inverse Problems approaches improves the estimation of particle size and 3D-position. Here we demonstrate the accurate tracking of colloidal particles in Brownian motion. Particle size and 3D-position are jointly optimized from video holograms acquired with a digital holographic microscopy set up based on a "low-end" microscope objective ($\times 20$, $\rm NA\ 0.5$). Exploiting information redundancy makes it possible to characterize particles with a standard deviation of 15 nm in size and a theoretical resolution of 2 x 2 x 5 nm$^3$ for position under additive white Gaussian noise assumption.

physics.ins-det

Holographic microscopy reconstruction in both object and image half spaces with undistorted 3D grid

We propose an holographic microscopy reconstruction method, which propagates the hologram, in the object half space, in the vicinity of the object. The calibration yields reconstructions with an undistorted reconstruction grid i.e. with orthogonal $x$, $y$ and $z$ axis and constant pixels pitch. The method is validated with an USAF target imaged by a $\times$60 microscope objective, whose holograms are recorded and reconstructed for different USAF locations along the longitudinal axis: -75 to +75 $μ$m. Since the reconstruction numerical phase mask, the reference phase curvature and MO form an afocal device, the reconstruction can be interpreted as occurring equivalently in the object or in image half space.

physics.optics

Laser Doppler holographic microscopy in transmission: application to fish embryo imaging

We have extended Laser Doppler holographic microscopy to transmission geometry. The technique is validated with living fish embryos imaged by a modified upright bio-microcope. By varying the frequency of the holographic reference beam, and the combination of frames used to calculate the hologram, multimodal imaging has been performed. Doppler images of the blood vessels for different Doppler shifts, images where the flow direction is coded in RGB colors or movies showing blood cells individual motion have been obtained as well. The ability to select the Fourier space zone that is used to calculate the signal, makes the method quantitative.

physics.optics

Phase-sensitive narrowband heterodyne holography

We report on amplitude and phase imaging of out-of-plane sinusoidal surface vibration at nanometer scales with a heterodyne holographic interferometer. The originality of the proposed method is to make use of a multiplexed local oscillator to address several optical sidebands into the temporal bandwidth of a sensor array. This process is called coherent frequency-division multiplexing. It enables simultaneous recording and pixel-to-pixel division of sideband holograms, which permits quantitative wide-field mapping of optical phase modulation depths. Additionally, a linear frequency chirp ensures the retrieval of the local mechanical phase shift of the vibration with respect to the excitation signal. The proposed approach is validated by quantitative motion characterization of the lamellophone of a musical box, behaving as a group of harmonic oscillators, under weak sinusoidal excitation. Images of the vibration amplitude versus excitation frequency show the resonance of the nanometric flexural response of one individual cantilever, at which a phase hop is measured. ©Optical Society of America.

physics.optics

Vibration motions studied by Heterodyne Holography

Playing with amplitude, phase and frequency of both reference and signal arms, heterodyne holography is well adapted to vibration analysis. Vibration sidebands can be imaged and stroboscopic measurement sensitive to mechanical phase can be made

physics.optics

Signal and Noise scaling factors in digital holography

An experimental study on how reconstructed image signal and noise scale with acquisition and reconstruction parameters is proposed. Monte-carlo simulation is performed to emphasize that the measured noise is shot-noise.

physics.optics

Phase-resolved heterodyne holographic vibrometry with a strobe local oscillator

We report a demonstration of phase-resolved vibrometry, in which out-of-plane sinusoidal motion is assessed by heterodyne holography. In heterodyne holography, the beam in the reference channel is an optical local oscillator (LO). It is frequency-shifted with respect to the illumination beam to enable frequency conversion within the sensor bandwidth. The proposed scheme introduces a strobe LO, where the reference beam is frequency-shifted and modulated in amplitude, to alleviate the issue of phase retrieval. The strobe LO is both tuned around the first optical modulation side band at the vibration frequency, and modulated in amplitude to freeze selected mechanical vibration states sequentially. The phase map of the vibration can then be derived from the demodulation of successive vibration states.

physics.optics

Digital in-line holography in thick optical systems: application to visualization in pipes

In this paper we apply digital in-line holography to image opaque objects through a thick plano-concave pipe. Opaque fibers and opaque particles are considered}. Analytical expression of the intensity distribution in the CCD sensor plane is derived using generalized Fresnel transform. \textbf{The proposed model has the ability to deal with various pipe shape and thickness and compensates for the lack of versatility of classical DIH models. Holograms obtained with a 12 mm thick plano-concave pipe are then reconstructed using fractional Fourier transform (FRFT).} This method allows us to get rid of astigmatism. Numerical and experimental results are presented.

physics.optics

Absolute measurement of small-amplitude vibrations by time-averaged heterodyne holography with a dual local oscillator

We report a demonstration of the measurement of the ratio between an optical modulation side band component and the non-shifted light component by time-averaged heterodyne holography in off-axis and frequency-shifting configuration, through coherent frequency-division multiplexing with a dual optical local oscillator. Experimental results of sinusoidal vibration sensing are reported. This technique enables absolute measurements of sub-nanometric out-of-plane vibration amplitudes.

physics.optics

(DH) Noise and Signal scaling factors in Digital Holography in week illumination: relationship with Shot Noise

We have performed off axis heterodyne holography with very weak illumination by recording holograms of the object with and without object illumination in the same acquisition run. We have experimentally studied, how the reconstructed image signal (with illumination) and noise background (without) scale with the holographic acquisition and reconstruction parameters that are the number of frames, and the number of pixels of the reconstruction spatial filter. The first parameter is related to the frequency bandwidth of detection in time, the second one to the bandwidth in space. The signal to background ratio varies roughly like the inverse of the bandwidth in time and space. We have also compared the noise background with the theoretical shot noise background calculated by Monte Carlo simulation. The experimental and Monte Carlo noise background agree very well together.

physics.optics

Off-axis digital hologram reconstruction: some practical considerations

Holographic rendering of off-axis intensity digital holograms is discussed. A review of some of the main numerical processing methods, based either on the Fourier transform interpretation of the propagation integral or on its linear system counterpart, is reported. Less common methods such as adjustable magnification reconstruction schemes and Fresnelet decomposition are presented and applied to the digital treatment of off-axis holograms. The influence of experimental parameters on the classical hologram reconstruction methods is assessed, offering guidelines for optimal image rendering regarding the hologram recording conditions.

physics.optics