Searcharxiv⌕ Search

arXiv subjects

Nicoleta Economou-Zavlanos

Publications and source records attributed to Nicoleta Economou-Zavlanos.

3 recordsLinked to original sources

Beyond Acuity Accuracy: A Multidimensional Framework for Evaluating Patient-Facing Emergency Triage AI Tools

Patient-facing AI triage tools may support care-seeking and emergency department prioritization, but require evaluation beyond acuity accuracy alone. We developed SAFE-Triage, a framework integrating human review, automated metrics, LLM-as-judge evaluation, and simulation testing across clinical performance, patient interaction, and clinician-facing summary quality. We applied SAFE-Triage to 40 MIMIC-IV-derived emergency vignettes and a 10,030-case acuity analysis comparing prompted LLM triage (PLT) with rule-augmented prompted LLM triage (rPLT). PLT achieved higher emergency severity index (ESI) accuracy (57.5% vs 42.8%, $P < 0.001$), lower undertriage (13.1% vs 29.8%, $P < 0.001$), and higher clinician ratings across all domains. rPLT produced shorter and more stable outputs with higher automated readability scores. SAFE-Triage identified trade-offs between acuity accuracy, undertriage risk, communication quality, readability, and summary quality, supporting pre-deployment refinement and ongoing monitoring by showing where triage tools are efficient, need improvement, or need clinician oversight.

cs.CL↗

An Agentic AI System for Multi-Framework Communication Coding

Clinical communication is central to patient outcomes, yet large-scale human annotation of patient-provider conversation remains labor-intensive, inconsistent, and difficult to scale. Existing approaches based on large language models typically rely on single-task models that lack adaptability, interpretability, and reliability, especially when applied across various communication frameworks and clinical domains. In this study, we developed a Multi-framework Structured Agentic AI system for Clinical Communication (MOSAIC), built on a LangGraph-based architecture that orchestrates four core agents, including a Plan Agent for codebook selection and workflow planning, an Update Agent for maintaining up-to-date retrieval databases, a set of Annotation Agents that applies codebook-guided retrieval-augmented generation (RAG) with dynamic few-shot prompting, and a Verification Agent that provides consistency checks and feedback. To evaluate performance, we compared MOSAIC outputs against gold-standard annotations created by trained human coders. We developed and evaluated MOSAIC using 26 gold standard annotated transcripts for training and 50 transcripts for testing, spanning rheumatology and OB/GYN domains. On the test set, MOSAIC achieved an overall F1 score of 0.928. Performance was highest in the Rheumatology subset (F1 = 0.962) and strongest for Patient Behavior (e.g., patients asking questions, expressing preferences, or showing assertiveness). Ablations revealed that MOSAIC outperforms baseline benchmarking.

cs.CL↗

SIMAX: A Scalable and Interpretable Framework for Multi-Fidelity and Annotated Clinician-Patient Dialogue Simulation

Background. The widespread deployment of ambient digital scribes is driving large-scale capture of clinician-patient dialogues. Human coding of clinical communication data remains costly, inconsistent, and difficult to scale, motivating AI-driven communication coding systems. However, evaluating these systems requires real-world dialogues and human-coded labels, both hard to obtain at scale. Methods. We developed SIMAX (Scalable and Interpretable Framework for Multi-Fidelity and Annotated Clinician-Patient Dialogue Simulation), a framework for generating controlled clinical dialogue data with reference behavioral annotations. SIMAX generates clinician-patient dialogues from predefined clinical scenarios, personas and voice conditions, and target communication behaviors. Behaviors are controlled using two codebooks: the Global Codebook for overall communication quality and the WISER Codebook for specific countable behaviors. We evaluated SIMAX using automated and human quality assessments and an example communication coding system. Results. SIMAX generated 3,388 simulated dialogues across three specialties, multiple visit stages, persona characteristics, and accent conditions. Automated assessment showed mean UTMOS and WV-MOS scores of 3.03 and 2.61, WER and CER of 0.07 and 0.05, and CLAP cosine similarity of 0.41, suggesting reasonable speech naturalness, high transcription fidelity, and positive text-audio correspondence. Human evaluation showed a median MOS of 4.67 and a median clinical realism score of 3.00. Downstream evaluation suggests that SIMAX can assess how a communication coding system responds to behavioral targets and reveal insufficient sensitivity in some dimensions. Conclusions. SIMAX generates controlled and reproducible simulated clinician-patient dialogues, providing a data foundation for developing, validating, and refining communication coding systems.

cs.CL↗