SearcharxivSearch

arXiv subjects

Niklas Wahl

Publications and source records attributed to Niklas Wahl.

At least 19 recordsLinked to original sources

GPU-accelerated superiorization on constrained physical problems with SupPy

The superiorization method (SM) is situated between feasibility-seeking and constrained optimization. Instead of aiming at the minimum of a given objective function over a constraint set, it seeks a feasible point at which the objective function value is reduced - though not necessarily minimal - rather than hard targets, or in which a mathematically optimal solution is not strictly required. While the method has been investigated for several applications in physics, its broader use has been limited, in part due to the lack of openly available software for researchers wishing to explore it. In this work we apply superiorization to three problems from applied physics: seismic image reconstruction, low-dose CT reconstruction and intensity-modulated radiotherapy treatment planning. These experiments are conducted with SupPy, an open-source modularized Python toolbox developed for this work, which supports execution of feasibility-seeking algorithms and their superiorized version on both the CPU and the GPU. In all three cases the superiorized algorithms achieve favorable results compared to feasibility-seeking alone, with reduced noise in the imaging examples and lowered body dose in the radiotherapy plans. For the radiotherapy case we further observe that superiorization produces clinically viable plans on infeasible constraint sets.

physics.comp-ph

Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report

Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens, MRI lacks electron density, and cone-beam CT (CBCT) requires correction for dose calculation. Synthetic CT (sCT) generation addresses these by converting MRI or CBCT into CT-equivalent images with accurate Hounsfield Unit (HU) values, enabling MRI-only RT and CBCT-based adaptive workflows. Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers across head and neck, thorax, and abdomen. Two tasks: MRI-to-CT (890 cases) and CBCT-to-CT (1,472 cases), evaluated via image similarity (MAE, PSNR, MS-SSIM), segmentation (Dice, HD95), and dosimetric metrics from photon and proton plans. With 803 participants and 12/13 valid submissions, Task 1 top performance reached MAE $64.8\pm21.3$ HU, PSNR $\sim$30 dB, MS-SSIM $\sim$0.936, Dice 0.79, photon $γ_{2\%/2\text{mm}}>98\%$, proton $γ\approx85\%$. Task 2 improved: MAE $48.3\pm13.4$ HU, PSNR 32.6 dB, MS-SSIM 0.968, Dice 0.86, photon $γ>99\%$, proton $γ\approx89\%$. Strong image--segmentation correlations ($ρ=0.78$--$0.79$) but moderate dose correlations confirmed image quality is insufficient as a dosimetric surrogate. Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability. Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon. SynthRAD2025 demonstrates that deep learning yields clinically relevant sCTs, especially for CBCT-to-CT, while identifying persistent MRI-to-CT challenges and underscoring dose-based evaluation as essential for clinical validation.

physics.med-ph

DoseRAD2026 Challenge dataset: AI accelerated photon and proton dose calculation for radiotherapy

Purpose: Accurate dose calculation is essential in radiotherapy for precise tumor irradiation while sparing healthy tissue. With the growing adoption of MRI-guided and real-time adaptive radiotherapy, fast and accurate dose calculation on CT and MRI is increasingly needed. The DoseRAD2026 dataset and challenge provide a public benchmark of paired CT and MRI data with beam-level photon and proton Monte Carlo dose distributions for developing and evaluating advanced dose calculation methods. Acquisition and validation methods: The dataset comprises paired CT and MRI from 115 patients (75 training, 40 testing) treated on an MRI-linac for thoracic or abdominal lesions, derived from the SynthRAD2025 dataset. Pre-processing included deformable image registration, air-cavity correction, and resampling. Ground-truth photon (6 MV) and proton dose distributions were computed using open-source Monte Carlo algorithms, yielding 40,500 photon beams and 81,000 proton beamlets. Data format and usage notes: Data are organized into photon and proton subsets with paired CT-MRI images, beam-level dose distributions, and JSON beam configuration files. Files are provided in compressed MetaImage (.mha) format. The dataset is released under CC BY-NC 4.0, with training data available from April 2026 and the test set withheld until March 2030. Potential applications: The dataset supports benchmarking of fast dose calculation methods, including beam-level dose estimation for photon and proton therapy, MRI-based dose calculation in MRI-guided workflows, and real-time adaptive radiotherapy.

physics.med-ph

Direct optimization of the probability of lesion origin in proton treatment planning for low-grade glioma patients

In proton therapy of low-grade glioma (LGG) patients, contrast-enhancing brain lesions (CEBLs) on magnetic resonance imaging are considered predictive of late radiation-induced lesions. From the observation that CEBLs tend to concentrate in regions of increased dose-averaged linear energy transfer (LET$_{\text{d}}$) and proximal to the ventricular system, the probability of lesion origin (POLO) model has been established as a multivariate logistic regression model for the voxel-wise probability prediction of the CEBL origin. To date, leveraging the predictive power of the POLO model for treatment planning relies on hand tuning the dose and LET$_{\text{d}}$ distribution to minimize the resulting probability predictions. In this paper, we therefore propose automated POLO model-based treatment planning by directly integrating POLO calculation and optimization into plan optimization for LGG patients. We introduce an extension of the original POLO model including a volumetric correction factor, and a model-based optimization scheme featuring a linear reformulation of the model together with feasible optimization functions based on the predicted POLO values. The developed framework is implemented in the open-source treatment planning toolkit matRad. Our framework can generate clinically acceptable treatment plans while automatically taking into account outcome predictions from the POLO model. It also supports the definition of customized POLO model-based objective and constraint functions. Optimization results from a sample LGG patient show that the POLO model-based outcome predictions can be minimized under expectable shifts in dose, LET$_{\text{d}}$, and POLO distributions, while sustaining target coverage ($Δ_{\text{PTV}} \text{D95}_{RBE,fx}\approx{0.00}$, $Δ_{\text{GTV}} \text{D95}_{RBE,fx}\approx{0.03}$), even when NTCP is strongly down-regulated.

physics.med-ph

Trading robustness: a scenario-free approach to robust Multi-Criteria Optimization for Treatment Planning

Treatment planning in radiotherapy is inherently a multi-criteria optimization (MCO) problem. Traditionally, the treatment's robustness is not formulated as a part of this decision making problem, but dealt with separately through margins or robust optimization. This work facilitates integration of robustness into multi-criteria optimization using a recently proposed efficient scenario-free (s-f) robust optimization approach: The s-f approach relies on the fast evaluation of the expected dose distribution and mean variance during optimization. This is achieved by precomputation of probabilistic quantities, which can then be used for repeated solving of subproblems in the two explored MCO approaches: Lexicographic Ordering (LO) and Pareto Front (PF) approximation. Different prioritization strategies within the LO approach are used to assess the impact of variance reduction while a 3-objective PF approximation, including a variance reduction objective, is generated to visualize and analyze trade-offs between the competing objectives. The robust optimization is performed including 100 scenarios modeling setup and range errors, as well as organ motion, on 3D- and 4DCT lung cancer patient datasets. Robustness analysis is performed to assess and explore the efficacy of all optimization strategies. The s-f approach enabled robust optimization in MCO with computational times comparable to nominal MCO. Both MCO strategies highlighted the interplay between dosimetric and variance reduction objectives. The LO approach showed how prioritization affects plan quality and robustness, while the PF analysis revealed a clear trade-off between robustness and organ-at-risk sparing. The reported analysis highlighted the conflicting trade-off nature of plan robustness and dosimetric quality, demonstrating how robust MCO supports a more informed and flexible decision-making process in treatment planning.

physics.med-ph

GPU-accelerated FREDopt package for simultaneous dose and LETd proton radiotherapy plan optimization via superiorization methods

This study presents FREDopt, a newly developed GPU-accelerated open-source optimization software for simultaneous proton dose and dose-averaged LET (LETd) optimization in IMPT treatment planning. FREDopt was implemented entirely in Python, leveraging CuPy for GPU acceleration and incorporating fast Monte Carlo (MC) simulations from the FRED code. The treatment plan optimization workflow includes pre-optimization and optimization, the latter equipped with a novel superiorization of feasibility-seeking algorithms. Feasibility-seeking requires finding a point that satisfies prescribed constraints. Superiorization interlaces computational perturbations into iterative feasibility-seeking steps to steer them toward a superior feasible point, replacing the need for costly full-fledged constrained optimization. The method was validated on two treatment plans of patients treated in a clinical proton therapy center, with dose and LETd distributions compared before and after reoptimization. Simultaneous dose and LETd optimization using FREDopt led to a substantial reduction of LETd and (dose)x(LETd) in organs at risk (OARs) while preserving target dose conformity. Computational performance evaluation showed execution times of 14-50 minutes, depending on the algorithm and target volume size-satisfactory for clinical and research applications while enabling further development of the well-tested, documented open-source software.

physics.med-ph

A high-order deterministic dynamical low-rank method for proton transport in heterogeneous media

Dose calculations in proton therapy require the fast and accurate solution of a high-dimensional transport equation for a large number of (pencil) beams with different energies and directions. Deterministically solving this transport problem at a sufficient resolution can however be prohibitively expensive, especially due to highly forward peaked scattering of the protons. We propose using a model order reduction approach, the dynamical low-rank approximation (DLRA), which evolves the solution on the manifold of low-rank matrices in (pseudo-)time. For this, we compare a collided-uncollided split of the linear Boltzmann equation and its Fokker-Planck approximation. We treat the uncollided part using a ray-tracer and combine high-order phase space discretizations and a mixture model for materials with DLRA for the collided equation. Our method reproduces the results of a full-rank reference code at significantly lower rank, and thus computational cost and memory, and further makes computations feasible at much higher resolutions. At higher resolutions, we also achieve good accuracy with respect to TOPAS MC in homogeneous as well as heterogeneous materials. Finally, we demonstrate that several beam sources with different angles can be computed with little cost increase compared to individual beams.

math.NA

LET-modifying joint optimization for mixed-modality photon-proton treatment planning

As depth increases, linear energy transfer (LET) rises toward the distal edge of the Bragg peak, boosting the radiobiological effectiveness (RBE). To manage the biological variation and limit normal-tissue damage, LET-modifying objective functions on, e.g., dose-weighted LET or dirty dose and/or usage of variable RBE models were introduced. Because shaping LET by proton irradiation alone has its limits, this work proposes to jointly optimize mixed-modality proton-photon treatments based on directly LET-modifying objective functions. The investigated objective functions rely on either dose-weighted LET or dirty dose concepts. To formulate a consistent combined optimization problem, the contribution of secondary electron LET in photon treatments is considered (and discussed) as well. Combined dose/LET calculation and optimization are realized in the open source toolkit matRad. Phantom plans as well as a patient plans are optimized for analysis on the method, combining five proton fractions with 25 photon fractions. Dose-optimized combined plans are used as a reference. The reference plan shows that protons are, in general, dosimetrically superior and thus preferred, with photons aiding in achieving conformity. The introduction of LET modified objectives locally modifies the proton contribution in the targeted regions of interest. Especially at the distal edge, the photon contribution increases to move high-LET/dirty dose out of the OARs. Dirty dose objectives seem to allow a more comprehensive steering of the high-LET regions compared to LETxDose. Incorporating LET-based objectives into a jointly optimized proton-photon system allows for improved dose conformity and reduced high-LET exposure in critical regions in proximity to the distal proton edge. This approach enables the utilization of modality-specific strengths and can contribute to safer, more effective treatment plans.

physics.med-ph

An ion treatment planning framework for inclusion of nanodosimetric ionization detail through cluster dose

Nanodosimetry relates Ionization Detail (ID) and ionization parameters (Ip) to biological endpoints relevant for charged-particle radiotherapy. This supports a more physics-based modeling of biological effectiveness than traditional dose-response relationships and RBE models. Faddegon et al. (2023) introduced cluster dose g(Ip) as a physical quantity, bridging ID to the treatment planning level, which can be directly optimized. We developed a framework enabling cluster dose optimization via a pencil-beam (PB) algorithm, and validated against Monte Carlo (MC) simulations. The framework, integrated into the treatment planning toolkit matRad, uses precomputed Ip values obtained from MC track-structure simulations. We applied our tool for plan optimization with protons, helium, and carbon ions in a water phantom and a prostate case. Recalculation with TOPAS showed 3D gamma passing rates >97% (phantom) and >98% (patient) using a 3%/3mm criterion and a threshold of 10% of the maximum dose. Cluster dose F5 optimization produced homogeneous target coverage, with heavier ions requiring lower absorbed doses for the same prescribed cluster dose level. This demonstrates the feasibility of fast, accurate cluster dose optimization using PB algorithms.

physics.med-ph

Helium Range Viability for Online Range Probing in Mixed Carbon-Helium Beams

Background: Recently, mixed carbon-helium beams were proposed for range verification in carbon ion therapy: Helium, with three times the range of carbon, serves as an on-line range probe, and is mixed into a therapeutic carbon beam. Purpose: Treatment monitoring is of special interest for lung cancer therapy, however the helium range might not always be sufficient to exit the patient distally. Therefore mixed beam use cases of several patient sites are considered. Methods: An extension to the open-source planning toolkit, matRad allows for calculation and optimization of mixed beam treatment plans. The use of the mixed beam method in 15 patients with lung cancer, as well as in a prostate and liver case, for various potential beam configurations was investigated. Planning strategies to optimize the residual helium range considering the sensitive energy range of the imaging detector were developed. A strategy involves adding helium to energies whose range is sufficient. Another one is to use range shifters to increase the helium energy and thus range. Results: In most patient cases, the residual helium range of at least one spot is too low. All investigated planning strategies can be used to ensure a high enough helium range while still keeping a low helium dose and a satisfactory total mixed carbon-helium beam dose. The use of range shifters allows for the detection of more spots. Conclusion: The mixed beam method shows promising results for online motioning. The use of range shifters ensures a high enough helium range and more detectable spots, allowing for a wider-spread application.

physics.med-ph

SynthRAD2025 Grand Challenge dataset: generating synthetic CTs for radiotherapy

Medical imaging is essential in modern radiotherapy, supporting diagnosis, treatment planning, and monitoring. Synthetic imaging, particularly synthetic computed tomography (sCT), is gaining traction in radiotherapy. The SynthRAD2025 dataset and Grand Challenge promote advancements in sCT generation by providing a benchmarking platform for algorithms using cone-beam CT (CBCT) and magnetic resonance imaging (MRI). The dataset includes 2362 cases: 890 MRI-CT and 1472 CBCT-CT pairs from head-and-neck, thoracic, and abdominal cancer patients treated at five European university medical centers (UMC Groningen, UMC Utrecht, Radboud UMC, LMU University Hospital Munich, and University Hospital of Cologne). Data were acquired with diverse scanners and protocols. Pre-processing, including rigid and deformable image registration, ensures high-quality, modality-aligned images. Extensive quality assurance validates image consistency and usability. All imaging data is provided in MetaImage (.mha) format, ensuring compatibility with medical image processing tools. Metadata, including acquisition parameters and registration details, is available in structured CSV files. To maintain dataset integrity, SynthRAD2025 is divided into training (65%), validation (10%), and test (25%) sets. The dataset is accessible at https://doi.org/10.5281/zenodo.14918089 under the SynthRAD2025 collection. This dataset supports benchmarking and the development of synthetic imaging techniques for radiotherapy applications. Use cases include sCT generation for MRI-only and MR-guided photon/proton therapy, CBCT-based dose calculations, and adaptive radiotherapy workflows. By integrating diverse acquisition settings, SynthRAD2025 fosters robust, generalizable image synthesis algorithms, advancing personalized cancer care and adaptive radiotherapy.

physics.med-ph

A Deterministic Dynamical Low-rank Approach for Charged Particle Transport

Deterministically solving charged particle transport problems at a sufficient spatial and angular resolution is often prohibitively expensive, especially due to their highly forward peaked scattering. We propose a model order reduction approach which evolves the solution on a low-rank manifold in time, making computations feasible at much higher resolutions and reducing the overall run-time and memory footprint. For this, we use a hybrid dynamical low-rank approach based on a collided-uncollided split, i.e., the transport equation is split through a collision source method. Uncollided particles are described using a ray tracer, facilitating the inclusion of boundary conditions and straggling, whereas collided particles are represented using a moment method combined with the dynamical low-rank approximation. Here the energy is treated as a pseudo-time and a rank adaptive integrator is chosen to dynamically adapt the rank in energy. We can reproduce the results of a full-rank reference code at a much lower rank and thus computational cost and memory usage. The solution further achieves comparable accuracy with respect to TOPAS MC as previous deterministic approaches.

math.NA

Scenario-free robust optimization algorithm for IMRT and IMPT treatment planning

Robust treatment planning algorithms for Intensity Modulated Proton Therapy (IMPT) and Intensity Modulated Radiation Therapy (IMRT) allow for uncertainty reduction in the delivered dose distributions through explicit inclusion of error scenarios. Due to the curse of dimensionality, application of such algorithms can easily become computationally prohibitive. This work proposes a scenario-free probabilistic robust optimization algorithm that overcomes both the runtime and memory limitations typical of traditional robustness algorithms. The scenario-free approach minimizes cost-functions evaluated on expected-dose distributions and total variance. Calculation of these quantities relies on precomputed expected-dose-influence and total-variance-influence matrices, such that no scenarios need to be stored for optimization. The algorithm was developed within matRad and tested in several optimization configurations for photon and proton irradiation plans. A traditional robust optimization algorithm and a margin-based approach are used as a reference to benchmark the performances of the scenario-free algorithm in terms of plan quality, robustness and computational workload. The scenario-free approach achieves plan quality compatible with traditional robust optimization algorithms and it reduces the standard deviation within selected structures when variance reduction objectives are defined. Avoiding the storage of individual scenario information allows for the inclusion of an arbitrary number of error scenarios. The observed optimization time is independent on the number of included scenarios, compatible with a nominal, non-robust algorithm and significantly lower than the traditional robust approach. These properties make the scenario-free approach suitable for the optimization of robust plans involving a high number of error scenarios and CT phases as 4D robust optimization.

physics.med-ph

Ionization detail parameters and cluster dose: A mathematical model for selection of nanodosimetric quantities for use in treatment planning in charged particle radiotherapy

Objective: To propose a mathematical model for applying Ionization Detail (ID), the detailed spatial distribution of ionization along a particle track, to proton and ion beam radiotherapy treatment planning (RTP). Approach: Our model provides for selection of preferred ID parameters (I_p) for RTP, that associate closest to biological effects. Cluster dose is proposed to bridge the large gap between nanoscopic I_p and macroscopic RTP. Selection of I_p is demonstrated using published cell survival measurements for protons through argon, comparing results for nineteen Ip: N_k; k = 2,3,...,10, the number of ionizations in clusters of k or more per particle, and F_k; k = 1,2,...,10, the number of clusters of k or more per particle. We then describe application of the model to ID-based RTP and propose a path to clinical translation. Main results: The preferred I_p were N_4 and F_5 for aerobic cells, N_5 and F_7 for hypoxic cells. Signifcant differences were found in cell survival for beams having the same LET or the preferred N_k. Conversely, there was no signi?cant difference for F_5 for aerobic cells and F_7 for hypoxic cells, regardless of ion beam atomic number or energy. Further, cells irradiated with the same cluster dose for these I_p had the same cell survival. Based on these preliminary results and other compelling results in nanodosimetry, it is reasonable to assert that I_p exist that are more closely associated with biological effects than current LET-based approaches and microdosimetric RBE-based models used in particle RTP. However, more biological variables such as cell line and cycle phase, as well as ion beam pulse structure and rate still need investigation. Signifcance: Our model provides a practical means to select preferred I_p from radiobiological data, and to convert I_p to the macroscopic cluster dose for particle RTP.

physics.med-ph

BayesDose: Comprehensive proton dose prediction with model uncertainty using Bayesian LSTMs

We propose the BayesDose-Framework, a Bayesian approach for fast and accurate dose prediction in proton therapy. Our framework is based on a previously published deterministic LSTM model and is trained and evaluated on simulated beamlet doses from water phantoms and patient geometries. We parameterize the network's weights using 2D Gaussian mixture models and use ensemble predictions to quantify mean dose predictions and their standard deviation. The BayesDose model performs similarly to the deterministic variant. The uncertainty predictions are conservative but correlate well spatially and in magnitude with dose differences. This correlation is reduced when applied to patient data with unseen relative stopping power value ranges, which could be successfully addressed by re-training. We parallelize predictions and presample network weights to reduce runtime overhead. Bayesian models like BayesDose can provide fast predictions with quality equal to deterministic models and may support decision making and quality assurance in clinical settings in the future.

physics.med-ph

A novel inverse algorithm to solve IPO-IMPT of proton FLASH therapy with sparse filters

Purpose:The recently proposed IPO-IMPT framework allows simultaneous optimization of dose, dose rate, and LET for FLASH treatment planning. Finding solutions to IPO-IMPT is difficult due to computational intensiveness. Nevertheless, an inverse solution that simultaneously specifies the geometry of a sparse filter and weights of a proton intensity map is desirable for both clinical and preclinical applications. Such solutions can reduce effective biological dose to organs at risk in cancer patients as well as reduce the number of animal irradiations needed to derive extra biological dose models in preclinical studies. Methods:Unlike our initial forward heuristic, this inverse IPO-IMPT solution includes simultaneous optimization of sparse range compensation, sparse range modulation, and spot intensity. The daunting computational tasks vital to this endeavor were resolved iteratively with a distributed computing framework to enable Simultaneous Intensity and Energy Modulation and Compensation (SIEMAC). SIEMAC was demonstrated on a human lung cancer patient and a minipig. Results:SIEMAC improves maps of spot intensities and patient-field-specific sparse range compensators and range modulators. For the lung cancer patient, at our max nozzle current of 300 nA, dose rate coverage above 100 Gy/s increased from 57% to 96% in the lung and from 93% to 100% in the heart, and LET coverage above 4 keV/um dropped from 68% to 9% in the lung and from 26% to <1% in the heart. For a simple minipig plan, the FWHM of the dose, dose rate, and LET distributions decreased by 30%, 1.6%, and 57%, respectively, again with similar target dose coverage, thus reducing uncertainty in these quantities for preclinical studies. Conclusion:The inverse solution to IPO-IMPT demonstrated the capability to simultaneously modulate sub-spot proton energy and intensity distributions for clinical and preclinical studies.

physics.med-ph

Superiorization as a novel strategy for linearly constrained inverse radiotherapy treatment planning

We apply the superiorization methodology to the intensity-modulated radiation therapy (IMRT) treatment planning problem. In superiorization, linear voxel dose inequality constraints are the fundamental modeling tool within which a feasibility-seeking projection algorithm will seek a feasible point. This algorithm is then perturbed with gradient descent steps to reduce a nonlinear objective function. Within the open-source inverse planning toolkit matRad, we implement a prototypical algorithmic framework for superiorization using the well-established Agmon, Motzkin, and Schoenberg (AMS) feasibility-seeking projection algorithm and common nonlinear dose optimization objective functions. Based on this prototype, we apply superiorization to intensity-modulated radiation therapy treatment planning and compare its performance with feasibility-seeking and nonlinear constrained optimization. For these comparisons, we use the TG119 water phantom and a head-and-neck patient of the CORT dataset. Bare feasibility-seeking with AMS confirms previous studies, showing it can find solutions that are nearly equivalent to those found by the established piece-wise least-squares optimization approach. The superiorization prototype solved the linearly constrained planning problem with similar performance to that of a general-purpose nonlinear constrained optimizer while showing smooth convergence in both constraint proximity and objective function reduction. Superiorization is a useful alternative to constrained optimization in radiotherapy inverse treatment planning. Future extensions with other approaches to feasibility-seeking, e.g., with dose-volume constraints and more sophisticated perturbations, may unlock its full potential for high-performant inverse treatment planning.

physics.med-ph

An Integrated Biological Optimization framework for proton SBRT FLASH treatment planning allows dose, dose rate, and LET optimization using patient-specific ridge filters

Purpose: Patient-specific ridge filters can modulate proton energy to obtain a conformal dose. We describe a new framework for optimization of filter design and spot maps to meet the unique demands of FLASH radiotherapy. We demonstrate an Integrated Biological Optimization IMPT (IBO-IMPT) approach for optimization of dose, dose-averaged dose rate (DADR), and dose-averaged LET (LETd). Methods: We developed inverse planning software to design patient-specific ridge filters that spread the Bragg peak from a fixed-energy, 250 MeV beam to a proximal beam-specific planning target volume. The software optimizes patient-specific ridge filter and uses a Monte Carlo calculation engine, based on Geant4, to provide dose and LET influence matrices. Plan optimization, using matRAD, accommodates the IBO-IMPT objective function considering dose, dose rate, and LET simultaneously with minimum MU constraints. The framework enables design of both regularly spaced and sparse-optimized ridge filters, which allow faster delivery and selective LET optimization. Volume distributions and histograms for dose, DADR, and LETd are compared using evaluation structures specific to the heart and lung. Results: We used IBO-IMPT to design ridge filters for a central lung tumor patient. The IBO-IMPT framework selectively spared heart and lung by reducing LET and increasing dose rate, relative to IMPT planning. Sparse-optimized ridge filters were superior to regularly spaced ridge filters in dose rate. Together, these innovations substantially increased the DADR in the heart and lung while maintaining good target coverage. The volume that received a FLASH dose rate of higher 40 Gy/second increased by 31% for heart and 50% for lung. Conclusion: This proof-of-concept study demonstrates the feasibility of using an IBO-IMPT framework to accomplish proton FLASH SBPT, accounting for dose, DADR, and LETd simultaneously.

physics.med-ph