SearcharxivSearch

arXiv subjects

Nishi Doshi

Publications and source records attributed to Nishi Doshi.

5 recordsLinked to original sources

Night-Window Batching versus Carbon-Aware Scheduling for Clinical AI GPU Workloads

Hospitals run more machine learning on GPUs while the carbon footprint of grid electricity rises and falls through the day. Using a computer simulation, we compare $13$ scheduling rules on mixed GPU hardware, with synthetic patient-style jobs, urgency tiers, and time-of-day carbon traces. We do not study patient outcomes; every percentage we report is a simulator queue number, not a clinical finding. We ask whether running non-urgent jobs overnight is almost as good as a richer rule that mixes urgency and carbon (CUCA at weight 0.45, written CUCA$_{0.45}$). The comparison keeps carbon reduction secondary to clinical priority and deadline compliance, so each policy is judged on both average kg CO$_2$e and missed-deadline behavior. CarbonGreedy and CarbonShift are carbon-first stress tests that demonstrate how poorly wrong vendor presets can disrupt clinical priorities, and are not meant for production. Numbers are averages over many test settings, with wide run-to-run spread and no statistical adjustment, so headline ratios are exploratory. On an eight-GPU baseline, the overnight rule closes about $78\%$ of the carbon gap between urgency-only and CUCA$_{0.45}$ while missing fewer urgent deadlines than either. CarbonShift lets about $46\%$ of the most urgent jobs miss their deadline; this is simulated queueing, not bedside harm. At $48$ jobs per hour, the carbon footprints almost tie, yet the overnight rule still misses fewer urgent deadlines. A geography test, where regions share one daily carbon shape with only timezone shifts, trims under one percentage point of average carbon; a twelve-hour routine window saves a little carbon for CUCA$_{0.45}$ but raises overall missed deadlines. Overnight batching stays competitive on average modelled carbon; carbon-only rules belong only in stress tests.

cs.DC

A Cascaded Edge-Cloud Architecture for Automated Diabetic Retinopathy Screening

Diabetic Retinopathy (DR) is one of the leading causes of preventable blindness, and automated screening can help extend specialist capacity in resource-constrained clinical workflows. Cloud-based deep learning systems can provide strong grading performance, but they require image upload and reliable connectivity. We evaluate a two-tier edge-cloud cascade on the public APTOS 2019 Blindness Detection dataset. Tier 1 runs a lightweight MobileNetV3-small model locally to triage Referable DR (Classes 2-4) versus Non-referable DR (Classes 0-1). Tier 2 runs a RETFound-DINOv2 model in the cloud for ordinal severity grading only on images flagged as referable by Tier 1. On a stratified APTOS test split of 733 images, Tier 1 reaches 98.99% sensitivity and 84.37% specificity at a validation-tuned high-sensitivity threshold. The deployment-oriented safety-floor cascade forwards 49.52% of test images to Tier 2, reducing image-count cloud calls by 50.48% relative to a cloud-only model. In the deployed 4-class output space (Class 0-1 / Class 2 / Class 3 / Class 4), the safety-floor cascade obtains 77.49% accuracy and 0.7938 quadratic weighted kappa, while the cloud-only baseline obtains 80.76% accuracy and 0.8184 kappa. A Tier-2-override comparator improves accuracy to 80.49% and kappa to 0.8167, but downgrades 12 true referable cases after Tier 1 correctly forwarded them. We also report repeated stratified bootstrap variability, a prevalence-dependent cloud-call curve, raw-byte upload estimates, and CPU latency for the local tier. Index Terms: Diabetic retinopathy screening, retinal image analysis, edge-cloud computing, cascaded inference, teleophthalmology, clinical decision support, medical artificial intelligence, resource-constrained healthcare

cs.CV

Diabetic Retinopathy Classification using Downscaling Algorithms and Deep Learning

Diabetic Retinopathy (DR) is an art and science of recording and classifying the retinal images of a diabetic patient. DR classification deals with classifying retinal fundus image into five stages on the basis of severity of diabetes. One of the major issue faced while dealing with DR classification problem is the large and varying size of images. In this paper we propose and explore the use of several downscaling algorithms before feeding the image data to a Deep Learning Network for classification. For improving training and testing; we amalgamate two datasets: Kaggle and Indian Diabetic Retinopathy Image Dataset. Our experiments have been performed on a novel Multi Channel Inception V3 architecture with a unique self crafted preprocessing phase. We report results of proposed approach using accuracy, specificity and sensitivity, which outperform the previous state of the art methods. Index Terms: Diabetic Retinopathy, Downscaling Algorithms, Multichannel CNN Architecture, Deep Learning

cs.CV

Strategizing University Rank Improvement using Interpretable Machine Learning and Data Visualization

Annual ranking of higher educational institutions (HEIs) is a global phenomenon and have significant impact on higher education landscape. Most of the HEIs pay close attention to ranking results and look forward to improving their ranks. However, maintaining a good rank and ascending in the rankings is a difficult task because it requires considerable resources, efforts and performance improvement plan. In this work, firstly, we show how exploratory data analysis (EDA) using correlation heatmaps and box plots can aid in understanding the broad trends in the ranking data. Subsequently, we present a novel idea of classifying the rankings data using Decision Tree (DT) based algorithms and retrieve decision paths for rank improvement using data visualization techniques. Using Laplace correction to the probability estimate, we quantify the amount of certainty attached with different decision paths obtained from interpretable DT models. The proposed methodology can aid Universities and HEIs to quantitatively assess the scope of improvement, adumbrate a fine-grained long-term action plan and prepare a suitable road-map.

cs.LG

Image Aesthetics Assessment using Multi Channel Convolutional Neural Networks

Image Aesthetics Assessment is one of the emerging domains in research. The domain deals with classification of images into categories depending on the basis of how pleasant they are for the users to watch. In this article, the focus is on categorizing the images in high quality and low quality image. Deep convolutional neural networks are used to classify the images. Instead of using just the raw image as input, different crops and saliency maps of the images are also used, as input to the proposed multi channel CNN architecture. The experiments reported on widely used AVA database show improvement in the aesthetic assessment performance over existing approaches.

cs.CV