SearcharxivSearch

arXiv subjects

Nobuhiko Katayama

Publications and source records attributed to Nobuhiko Katayama.

At least 19 recordsLinked to original sources

Constraints on axion-like polarization oscillations in the cosmic microwave background with POLARBEAR

Very light pseudoscalar fields, often referred to as axions, are compelling dark matter candidates and can potentially be detected through their coupling to the electromagnetic field. Recently a novel detection technique using the cosmic microwave background (CMB) was proposed, which relies on the fact that the axion field oscillates at a frequency equal to its mass in appropriate units, leading to a time-dependent birefringence. For appropriate oscillation periods this allows the axion field at the telescope to be detected via the induced sinusoidal oscillation of the CMB linear polarization. We search for this effect in two years of POLARBEAR data. We do not detect a signal, and place a median $95 \%$ upper limit of $0.65 ^\circ$ on the sinusoid amplitude for oscillation frequencies between $0.02\,\text{days}^{-1}$ and $0.45\,\text{days}^{-1}$, which corresponds to axion masses between $9.6 \times 10^{-22} \, \text{eV}$ and $2.2\times 10^{-20} \,\text{eV}$. Under the assumptions that 1) the axion constitutes all the dark matter and 2) the axion field amplitude is a Rayleigh-distributed stochastic variable, this translates to a limit on the axion-photon coupling $g_{ϕγ} < 2.4 \times 10^{-11} \,\text{GeV}^{-1} \times ({m_ϕ}/{10^{-21} \, \text{eV}})$.

astro-ph.CO

Vibration characteristics of a continuously rotating superconducting magnetic bearing and potential influence to TES and SQUID

We measured the vibration of a prototype superconducting magnetic bearing (SMB) operating at liquid nitrogen temperature. This prototype system was designed as a breadboard model for LiteBIRD low-frequency telescope (LFT) polarization modulator unit. We set an upper limit of the vibration amplitude at $36~\mathrm{μm}$ at the rotational synchronous frequency. During the rotation, the amplitude of the magnetic field produced varies. From this setup, we compute the static and AC amplitude of the magnetic fields produced by the SMB magnet at the location of the LFT focal plane as $0.24~\mathrm{G}$ and $3\times10^{-5}$$~\mathrm{G}$, respectively. From the AC amplitude, we compute TES critical temperature variation of $7\times10^{-8}$$~\mathrm{K}$ and fractional change of the SQUID flux is $δΦ/Φ_0|_{ac}=3.1\times10^{-5}$. The mechanical vibration can be also estimated to be $3.6\times 10^{-2}$$~\mathrm{N}$ at the rotation mechanism location.

physics.ins-det

High-precision temperature monitoring system for room-temperature equipment in astrophysical observations

We present a precise thermometry system to monitor room-temperature components of a telescope for radio-astronomy such as cosmic microwave background (CMB) observation. The system realizes precision of 1 mK${\rm \sqrt{s}}$ on a timescale of 20 seconds at 300 K. We achieved this high precision by tracking only relative fluctuation and combining thermistors with a low-noise measurement device. We show the required precision of temperature monitors for CMB observation and introduce the performance of our thermometry system. This precise room-temperature monitoring system enables us to reduce the low-frequency noise in a wide range of radio-astronomical detector signals observation and to operate a large detector array perform at its designed high sensitivity.

astro-ph.IM

Testbed preparation of a small prototype polarization modulator for LiteBIRD low-frequency telescope

LiteBIRD is the Cosmic Microwave Background (CMB) radiation polarization satellite mission led by ISAS/JAXA. The main scientific goal is to search for primordial gravitational wave signals generated from the inflation epoch of the Universe. LiteBIRD telescopes employ polarization modulation units (PMU) using continuously rotating half-wave plates (HWP). The PMU is a crucial component to reach unprecedented sensitivity by mitigating systematic effects, including 1/f noise. We have developed a 1/10 scale prototype PMU of the LiteBIRD LFT, which has a 5-layer achromatic HWP and a diameter of 50 mm, spanning the observational frequency range of 34-161 GHz. The HWP is mounted on a superconducting magnetic bearing (SMB) as a rotor and levitated by a high-temperature superconductor as a stator. In this study, the entire PMU system is cooled down to 10 K in the cryostat chamber by a 4-K Gifford-McMahon (GM) cooler. We propagate an incident coherent millimeter-wave polarized signal throughout the rotating HWP and detect the modulated signal. We study the modulated optical signal and any rotational synchronous signals from the rotation mechanism. We describe the testbed system and the preliminary data acquired from this setup. This testbed is built to integrate the broadband HWP PMU and evaluate the potential systematic effects in the optical data. This way, we can plan with a full-scale model, which takes a long time for preparation and testing.

astro-ph.IM

Modelling TES non-linearity induced by a rotating HWP in a CMB polarimeter

Most upcoming CMB experiments are planning to deploy between a few thousand and a few hundred thousand TES bolometers in order to drastically increase sensitivity and unveil the B-mode signal. Differential systematic effects and $1/f$ noise are two of the challenges that need to be overcome in order to achieve this result. In recent years, rotating Half-Wave Plates have become increasingly more popular as a solution to mitigate these effects, especially for those experiments that are targeting the largest angular scales. However, other effects may appear when a rotating HWP is being employed. In this paper we focus on HWP synchronous signals, which are due to intensity to polarization leakage induced by a rotating cryogenic multi-layer sapphire HWP employed as the first optical element of the telescope system. We use LiteBIRD LFT as a case study and we analyze the interaction between these spurious signals and TES bolometers, to determine whether this signal can contaminate the bolometer response. We present the results of simulations for a few different TES model assumptions and different spurious signal amplitudes. Modelling these effects is fundamental to find what leakage level can be tolerated and minimize non-linearity effects of the bolometer response.

astro-ph.IM

Testing magnetic interference between TES detectors and the telescope environment for future CMB satellite missions

The two most common components of several upcoming CMB experiments are large arrays of superconductive TES (Transition-Edge Sensor) detectors and polarization modulator units, e.g. continuously-rotating Half-Wave Plates (HWP). A high detector count is necessary to increase the instrument raw sensitivity, however past experiments have shown that systematic effects are becoming one of the main limiting factors to reach the sensitivity required to detect primordial $B$-modes. Therefore, polarization modulators have become popular in recent years to mitigate several systematic effects. Polarization modulators based on HWP technologies require a rotating mechanism to spin the plate and modulate the incoming polarized signal. In order to minimize heat dissipation from the rotating mechanism, which is a stringent requirement particularly for a space mission like $LiteBIRD$, we can employ a superconductive magnetic bearing to levitate the rotor and achieve contactless rotation. A disadvantage of this technique is the associated magnetic fields generated by those systems. In this paper we investigate the effects on a TES detector prototype and find no detectable $T_c$ variations due to an applied constant (DC) magnetic field, and a non-zero TES response to varying (AC) magnetic fields. We quantify a worst-case TES responsivity to the applied AC magnetic field of $\sim10^5$ pA/G, and give a preliminary interpretation of the pick-up mechanism.

astro-ph.IM

A Large Diameter Millimeter-Wave Low-Pass Filter Made of Alumina with Laser Ablated Anti-Reflection Coating

We fabricated a 302 mm diameter low-pass filter made of alumina that has an anti-reflection coating (ARC) made with laser-ablated sub-wavelength structures (SWS). The filter has been integrated into and is operating with the MUSTANG2 instrument, which is coupled to the Green Bank Telescope. The average transmittance of the filter in the MUSTANG2 operating band between 75 and 105 GHz is 98%. Reflective loss due to the ARC is 1%. The difference in transmission between the s- and p-polarization states is less than 1%. To within 1% accuracy we observe no variance in these results when transmission is measured in six independent filter spatial locations. The alumina filter replaced a prior MUSTANG2 Teflon filter. Data taken with the filter heat sunk to its nominal 40 K stage show performance consistent with expectations: a reduction of about 50% in filters-induced optical power load on the 300 mK stage, and in in-band optical loading on the detectors. It has taken less than 4 days to laser-ablate the SWS on both sides of the alumina disk. This is the first report of an alumina filter with SWS ARC deployed with an operating instrument, and the first demonstration of a large area fabrication of SWS with laser ablation.

astro-ph.IM

Mechanical strength and millimeter-wave transmittance spectrum of stacked sapphire plates bonded by sodium silicate solution

The polarization modulator unit for the low-frequency telescope in LiteBIRD employs an achromatic half-wave plate (AHWP). It consists of five layers of a-cut sapphire plate, which are stacked based on a Pancharatnam recipe. In this way, the retardance of the AHWP is a half-wave over a bandwidth of 34-161 GHz. The diameter of a single sapphire plate is about 500 mm and the thickness is 5 mm. When a large diameter AHWP is used for a space mission, it is important for the AHWP to survive launch vibration. A preliminary study indicates that the five-layer stacked HWP has a risk of breakage at the launch unless the five layers are glued together and mechanically treated as one disk. We report our investigation using a sodium silicate solution that can bond the sapphire plates. This technique has been previously investigated as a candidate of cryogenic bonding for a mirror material, including sapphire, of the gravitational wave experiments: LIGO, VIRGO, and KAGRA. We experimentally studied the mechanical strength of the bonded interface for two different surface conditions: polished and unpolished. We demonstrated that the tensile and shear strength > 20 MPa for samples with a polished surface. This satisfied the requirement of 5.5 MPa derived from the mechanical simulation assuming a launch load of 30G. We identified that samples glued on a polished surface exhibit higher strength than unpolished ones by a factor of 2 for tensile and 18 for shear strength. We measured the millimeter-wave transmittance between 90 and 140 GHz using sapphire plates with a diameter of 50 mm before and after bonding. We did not find any optical effects caused by the bonded interface within 2% error in transmittance, which originates from the measurement system.

astro-ph.IM

Design of a frequency-independent optic axis Pancharatnam-based achromatic half-wave plate

Pancharatnam-based achromatic half-wave plates (AHWP) achieve high polarization efficiency over a broad waveband. These AWHPs generally contain a property whereby the optic axis is dependent on the electromagnetic frequency of the incident radiation. When the AHWP is used to measure incident polarized radiation with a finite detection bandwidth, this frequency dependence causes an uncertainty in the determination of the polarization angle due to the limited knowledge of the shape of the source spectrum and detection band. To mitigate this problem, we propose new designs of the AHWP which eliminate the frequency dependence of the optic axis over the bandwidth whilst maintaining high modulation efficiency. We carried out this optimization by tuning the relative angles among the individual half-wave plates of the five and nine layer AHWPs. The optimized set of relative angles achieves a frequency-independent optic axis over the fractional bandwidth, a bandwidth over which polarization efficiency is greater than 0.9, of 1.3 and 1.5 for the five and nine layer AHWPs, respectively. We also study the susceptibility of the alignment accuracy on the polarization efficiency and the frequency dependence of the optic axis, which provides a design guidance for each application.

astro-ph.IM

FPFS Shear Estimator: Systematic Tests on the Hyper Suprime-Cam Survey First Year Data

We apply the Fourier Power Function Shapelets (FPFS) shear estimator to the first year data of the Hyper Suprime-Cam survey to construct a shape catalog. The FPFS shear estimator has been demonstrated to have multiplicative bias less than $1\%$ in the absence of blending, regardless of complexities of galaxy shapes, smears of point spread functions (PSFs) and contamination from noise. The blending bias is calibrated with realistic image simulations, which include the impact of neighboring objects, using the COSMOS Hubble Space Telescope images. Here we carefully test the influence of PSF model residual on the FPFS shear estimation and the uncertainties in the shear calibration. Internal null tests are conducted to characterize potential systematics in the FPFS shape catalog and the results are compared with those measured using a catalog where the shapes were estimated using the re-Gaussianization algorithms. Furthermore, we compare various weak lensing measurements between the FPFS shape catalog and the re-Gaussianization shape catalog and conclude that the weak lensing measurements between these two shape catalogs are consistent with each other within the statistical uncertainty.

astro-ph.CO

Simons Observatory Small Aperture Telescope overview

The Simons Observatory (SO) is a cosmic microwave background (CMB) experiment from the Atacama Desert in Chile comprising three small-aperture telescopes (SATs) and one large-aperture telescope (LAT). In total, SO will field over 60,000 transition-edge sensor (TES) bolometers in six spectral bands centered between 27 and 280 GHz in order to achieve the sensitivity necessary to measure or constrain numerous cosmological quantities. In this work, we focus on the SATs which are optimized to search for primordial gravitational waves that are detected as parity-odd polarization patterns called a B-modes on degree scales in the CMB. Each SAT employs a single optics tube with TES arrays operating at 100 mK. The high throughput optics system has a 42 cm aperture and a 35-degree field of view coupled to a 36 cm diameter focal plane. The optics consist of three metamaterial anti-re ection coated silicon lenses. Cryogenic ring baffles with engineered blackbody absorbers are installed in the optics tube to minimize the stray light. The entire optics tube is cooled to 1 K. A cryogenic continuously rotating half-wave plate near the sky side of the aperture stop helps to minimize the effect of atmospheric uctuations. The telescope warm baffling consists of a forebaffle, an elevation stage mounted co-moving shield, and a fixed ground shield that together control the far side-lobes and mitigates ground-synchronous systematics. We present the status of the SAT development.

astro-ph.IM

Measurement of the Cosmic Microwave Background Polarization Lensing Power Spectrum from Two Years of POLARBEAR Data

We present a measurement of the gravitational lensing deflection power spectrum reconstructed with two seasons cosmic microwave background polarization data from the POLARBEAR experiment. Observations were taken at 150 GHz from 2012 to 2014 which survey three patches of sky totaling 30 square degrees. We test the consistency of the lensing spectrum with a Cold Dark Matter (CDM) cosmology and reject the no-lensing hypothesis at a confidence of 10.9 sigma including statistical and systematic uncertainties. We observe a value of A_L = 1.33 +/- 0.32 (statistical) +/- 0.02 (systematic) +/- 0.07 (foreground) using all polarization lensing estimators, which corresponds to a 24% accurate measurement of the lensing amplitude. Compared to the analysis of the first year data, we have improved the breadth of both the suite of null tests and the error terms included in the estimation of systematic contamination.

astro-ph.CO

The POLARBEAR Fourier Transform Spectrometer Calibrator and Spectroscopic Characterization of the POLARBEAR Instrument

We describe the Fourier Transform Spectrometer (FTS) used for in-field testing of the POLARBEAR receiver, an experiment located in the Atacama Desert of Chile which measures the cosmic microwave background (CMB) polarization. The POLARBEAR-FTS (PB-FTS) is a Martin-Puplett interferometer designed to couple to the Huan Tran Telescope (HTT) on which the POLARBEAR receiver is installed. The PB-FTS measured the spectral response of the POLARBEAR receiver with signal-to-noise ratio (SNR) $>20$ for $\sim$69% of the focal plane detectors due to three features: a high throughput of 15.1 steradian cm$^{2}$, optimized optical coupling to the POLARBEAR optics using a custom designed output parabolic mirror, and a continuously modulated output polarizer. The PB-FTS parabolic mirror is designed to mimic the shape of the 2.5 m-diameter HTT primary reflector which allows for optimum optical coupling to the POLARBEAR receiver, reducing aberrations and systematics. One polarizing grid is placed at the output of the PB-FTS, and modulated via continuous rotation. This modulation allows for decomposition of the signal into different harmonics that can be used to probe potentially pernicious sources of systematic error in a polarization-sensitive instrument. The high throughput and continuous output polarizer modulation features are unique compared to other FTS calibrators used in the CMB field. In-field characterization of the POLARBEAR receiver was accomplished using the PB-FTS in April 2014. We discuss the design, construction, and operation of the PB-FTS and present the spectral characterization of the POLARBEAR receiver. We introduce future applications for the PB-FTS in the next-generation CMB experiment, the Simons Array.

astro-ph.IM

Demonstration of the broadband half-wave plate using the nine-layer sapphire for the CMB polarization experiment

We report the development of the achromatic half-wave plate (AHWP) at millimeter wave for cosmic microwave background polarization experiments. We fabricate an AHWP consisting of nine a-cut sapphire plates based on the Pancharatnam recipe to cover a wide frequency range. The modulation efficiency and the phase are measured in a frequency range of 33 to 260 GHz with incident angles up to 10 degrees. We find the measurements at room temperature are in good agreement with the predictions. This is the broadest demonstration of the AHWP at the millimeter wave.

astro-ph.IM

Design of a testbed for the study of system interference in space CMB polarimetry

LiteBIRD is a proposed JAXA satellite mission to measure the CMB B-mode polarization with unprecedented sensitivity ($σ_r\sim 0.001$). To achieve this goal, $4676$ state-of-the-art TES bolometers will observe the whole sky for 3 years from L2. These detectors, as well as the SQUID readout, are extremely susceptible to EMI and other instrumental disturbances e.g. static magnetic field and vibration. As a result, careful analysis of the interference between the detector system and the rest of the telescope instruments is essential. This study is particularly important during the early phase of the project, in order to address potential problems before the final assembly of the whole instrument. We report our plan for the preparation of a cryogenic testbed to study the interaction between the detectors and other subsystems, especially a polarization modulator unit consisting of a magnetically-rotating half wave plate. We also present the requirements, current status and preliminary results.

astro-ph.IM

Evidence for the Cross-correlation between Cosmic Microwave Background Polarization Lensing from POLARBEAR and Cosmic Shear from Subaru Hyper Suprime-Cam

We present the first measurement of cross-correlation between the lensing potential, reconstructed from cosmic microwave background (CMB) {\it polarization} data, and the cosmic shear field from galaxy shapes. This measurement is made using data from the POLARBEAR CMB experiment and the Subaru Hyper Suprime-Cam (HSC) survey. By analyzing an 11~deg$^2$ overlapping region, we reject the null hypothesis at 3.5$σ$\ and constrain the amplitude of the {\bf cross-spectrum} to $\widehat{A}_{\rm lens}=1.70\pm 0.48$, where $\widehat{A}_{\rm lens}$ is the amplitude normalized with respect to the Planck~2018{} prediction, based on the flat $Λ$ cold dark matter cosmology. The first measurement of this {\bf cross-spectrum} without relying on CMB temperature measurements is possible due to the deep POLARBEAR map with a noise level of ${\sim}$6\,$μ$K-arcmin, as well as the deep HSC data with a high galaxy number density of $n_g=23\,{\rm arcmin^{-2}}$. We present a detailed study of the systematics budget to show that residual systematics in our results are negligibly small, which demonstrates the future potential of this cross-correlation technique.

astro-ph.CO

Simultaneous determination of the cosmic birefringence and miscalibrated polarisation angles from CMB experiments

We show that the cosmic birefringence and miscalibrated polarisation angles can be determined simultaneously by cosmic microwave background (CMB) experiments using the cross-correlation between $E$- and $B$-mode polarisation data. This is possible because polarisation angles of the CMB are rotated by both the cosmic birefringence and miscalibration effects,whereas those of the Galactic foreground emission only by the latter. Our method does not require prior knowledge of the $E$- and $B$-mode power spectra of the foreground emission, but uses only the knowledge of the CMB polarisation spectra. Specifically, we relate the observed $EB$ correlation to the difference between the $\mathit{observed}$ $E$- and $B$-mode spectra in the sky, and use different multipole dependence of the CMB (given by theory) and foreground spectra (with no assumption) to derive the likelihood for the miscalibration angle $α$ and the birefringence angle $β$. We show that a future satellite mission similar to LiteBIRD can determine $β$ with a precision of ten arcminutes.

astro-ph.CO

Delta-map method to remove CMB foregrounds with spatially varying spectra

We extend the internal template foreground removal method by accounting for spatially varying spectral parameters such as the spectral indices of synchrotron and dust emission and the dust temperature. As the previous algorithm had to assume that the spectral parameters are uniform over the full sky (or some significant fraction of the sky), it resulted in a bias in the tensor-to-scalar ratio parameter $r$ estimated from foreground-cleaned polarization maps of the cosmic microwave background (CMB). The new algorithm, "Delta-map method", accounts for spatially varying spectra to first order in perturbation. The only free parameters are the cosmological parameters such as $r$ and the sky-averaged foreground parameters. We show that a cleaned CMB map is the maximum likelihood solution to first order in perturbation, and derive the posterior distribution of $r$ and the sky-averaged foreground parameters using Bayesian statistics. Applying this to realistic simulated sky maps including polarized CMB, synchrotron and thermal dust emission, we find that the new algorithm removes the bias in $r$ down to undetected level in our noiseless simulation ($r\lesssim 4\times 10^{-4}$). We show that the frequency decorrelation of polarized foregrounds due to averaging of spatially varying spectra can be accounted for to first order in perturbation by using slightly different spectral parameters for the Stokes $Q$ and $U$ maps. Finally, we show that the effect of polarized anomalous microwave emission on foreground removal can be absorbed into the curvature parameter of the synchrotron spectrum.

astro-ph.CO