SearcharxivSearch

arXiv subjects

Norbert Meidinger

Publications and source records attributed to Norbert Meidinger.

12 recordsLinked to original sources

Spectroscopic performance of the electrical functional models for the eXTP SFA-T detectors

The Spectroscopy Focusing Array (SFA) is one of the three instruments on the eXTP satellite. It consists of six telescopes plus focal plane cameras, where five are equipped with a Silicon Drift Detector (SDD) array. These five SFA-T (T stands for timing) instruments are used for observations with high time resolution (better than 10 microseconds), high throughput (dead time less than 5 % when observing a 1 Crab source), and good energy resolution (better than 180 eV at 6 keV). This paper presents the spectroscopic performance of the Electrical Functional Modules (EFM) for SFA-T that are assembled and tested at the Max Planck Institute for Extraterrestrial Physics (MPE). A focus lies on the energy resolution at the planned sensor operating temperature of -45 {\deg}C. Additionally, the use of a baffle that covers the pixel edges is studied.

astro-ph.IM

Multiwavelength Observations of the Apparently Non-repeating FRB 20250316A

The physical origin of fast radio bursts (FRBs) remains uncertain. Although multiwavelength observations have been widely conducted, only Galactic FRB~20200428D is associated with an X-ray burst from the magnetar SGR J1935+2154. Here, we present multiwavelength follow-up observations of the nearby bright FRB~20250316A, including the Five-hundred-meter Aperture Spherical radio Telescope (FAST), Einstein Probe (EP) X-ray mission, Chandra X-ray Observatory, Wide Field Survey Telescope (WFST) and Space Variable Object Monitor/Visible Telescope (SVOM/VT). The 13.08-hour FAST follow-up campaign without pulse detection requires an energy distribution flatter than those of well-known repeating FRBs, suggesting that this burst is likely a one-off event. A prompt EP follow-up and multi-epoch observational campaign totaling $>$ 100 ks led to the detection of an X-ray source within the angular resolution of its Follow-up X-ray Telescope (FXT, $10^{\prime\prime}$). A subsequent Chandra observation revealed this source to be offset by $7^{\prime\prime}$ from the FRB position, and established a 0.5-10 keV flux upper limit of $7.6\times 10^{-15}$ $\rm erg\,cm^{-2}\,s^{-1}$ at the FRB position, corresponding to $\sim 10^{39}$ $\rm erg\,s^{-1}$ at the 40 Mpc distance of the host galaxy NGC~4141. These results set one of the most stringent limits on X-ray emission from a non-repeating FRB, disfavoring ultra-luminous X-ray sources (ULXs) as counterparts of apparently one-off FRBs and offering critical insights into afterglow models. Our study suggests that an arcsecond localization of both the FRB and its potential X-ray counterpart is essential for exploring the X-ray counterpart of an FRB.

astro-ph.HE

The enhanced X-ray Timing and Polarimetry mission -- eXTP for launch in 2030

In this paper we present the current status of the enhanced X-ray Timing and Polarimetry mission, which has been fully approved for launch in 2030. eXTP is a space science mission designed to study fundamental physics under extreme conditions of matter density, gravity, and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring the effects of quantum electro-dynamics, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, the eXTP mission is poised to become a leading observatory for time-domain and multi-messenger astronomy in the 2030's, as well as providing observations of unprecedented quality on a variety of galactic and extragalactic objects. After briefly introducing the history and a summary of the scientific objectives of the eXTP mission, this paper presents a comprehensive overview of: 1) the cutting-edge technology, technical specifications, and anticipated performance of the mission's scientific instruments; 2) the full mission profile, encompassing spacecraft design, operational capabilities, and ground segment infrastructure.

astro-ph.HE

DEPFET Active Pixel Sensors

An array of DEPFET pixels is one of several concepts to implement an active pixel sensor. Similar to PNCCD and SDD detectors, the typically 0.45 mm thick silicon sensor is fully depleted by the principle of sideward depletion. They have furthermore in common to be back-illuminated detectors, which allows for ultra-thin and homogeneous photon entrance windows. This enables relatively high quantum efficiencies at low energies and close to 100% for photon energies between 1 keV and 10 keV. Steering of the DEPFET sensor is enabled by a so-called Switcher ASIC and readout is performed by e.g. a VERITAS ASIC. The configuration enables a readout time of a few microseconds per row. This results in full frame readout times of a few milliseconds for a 512 x 512 pixel array in a rolling shutter mode. The read noise is then typically three electrons equivalent noise charge RMS. DEPFET detectors can be applied in particular for spectroscopy in the energy band from 0.2 keV to 20 keV. For example, an energy resolution of about 130 eV FWHM is achieved at an energy of 6 keV which is close to the theoretical limit given by Fano noise. Pixel sizes of a few tens of microns up to a centimetre are feasible by the DEPFET concept.

astro-ph.IM

Mitigating the effects of particle background on the Athena Wide-Field Imager

The Wide Field Imager (WFI) flying on Athena will usher in the next era of studying the hot and energetic Universe. WFI observations of faint, diffuse sources will be limited by uncertainty in the background produced by high-energy particles. These particles produce easily identified "cosmic-ray tracks" along with signals from secondary photons and electrons generated by particle interactions with the instrument. The signal from these secondaries is identical to the X-rays focused by the optics, and cannot be filtered without also eliminating these precious photons. As part of a larger effort to understand the WFI background, we here present results from a study of background-reduction techniques that exploit the spatial correlation between cosmic-ray particle tracks and secondary events. We use Geant4 simulations to generate a realistic particle background, sort this into simulated WFI frames, and process those frames in a similar way to the expected flight and ground software to produce a WFI observation containing only particle background. The technique under study, Self Anti-Coincidence or SAC, then selectively filters regions of the detector around particle tracks, turning the WFI into its own anti-coincidence detector. We show that SAC is effective at improving the systematic uncertainty for observations of faint, diffuse sources, but at the cost of statistical uncertainty due to a reduction in signal. If sufficient pixel pulse-height information is telemetered to the ground for each frame, then this technique can be applied selectively based on the science goals, providing flexibility without affecting the data quality for other science. The results presented here are relevant for any future silicon-based pixelated X-ray imaging detector, and could allow the WFI and similar instruments to probe to truly faint X-ray surface brightness.

astro-ph.IM

Characterisation of the Particle-Induced Background of XMM-Newton EPIC-pn: Short and Long Term Variability

The particle-induced background of X-ray observatories is produced by Galactic Cosmic Ray (GCR) primary protons, electrons, and He ions. Events due to direct interaction with the detector are usually removed by on board processing. The interactions of these primary particles with the detector environment produce secondary particles that mimic X-ray events from celestial sources and are much more difficult to identify. The filter wheel closed data from the XMM-Newton EPIC-pn camera in small window mode (SWM) contains both the X-ray-like background events and the events due to direct interactions with the primary particles. From this data we demonstrate that X-ray-like background events are spatially correlated with the primary particle interaction. This result can be used to further characterise and reduce the non-X-ray background in silicon-based X-ray detectors in current and future missions. We also show that spectrum and pattern fractions of secondary particle events are different from those produced by cosmic X-rays.

astro-ph.HE

The enhanced X-ray Timing and Polarimetry mission - eXTP

In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, eXTP will be a very powerful observatory for astrophysics that will provide observations of unprecedented quality on a variety of galactic and extragalactic objects. In particular, its wide field monitoring capabilities will be highly instrumental to detect the electro-magnetic counterparts of gravitational wave sources. The paper provides a detailed description of: (1) the technological and technical aspects, and the expected performance of the instruments of the scientific payload; (2) the elements and functions of the mission, from the spacecraft to the ground segment.

astro-ph.IM

Magnetic shielding of soft protons in future X-ray telescopes: the case of the ATHENA Wide Field Imager

Both the interplanetary space and the Earth magnetosphere are populated by low energy ($\leq300$ keV) protons that are potentially able to scatter on the reflecting surface of Wolter-I optics of X-ray focusing telescopes and reach the focal plane. This phenomenon, depending on the X-ray instrumentation, can dramatically increase the background level, reducing the sensitivity or, in the most extreme cases, compromising the observation itself. The use of a magnetic diverter, deflecting protons away from the field of view, requires a detailed characterization of their angular and energy distribution when exiting the mirror. We present the first end-to-end Geant4 simulation of proton scattering by X-ray optics and the consequent interaction with the diverter field and the X-ray detector assembly, selecting the ATHENA Wide Field Imager as a case study for the evaluation of the residual soft proton induced background. We obtain that, in absence of a magnetic diverter, protons are indeed funneled towards the focal plane, with a focused Non X-ray Background well above the level required by ATHENA science objectives ($5\times10^{-4}$ counts cm$^{-2}$ s$^{-1}$ keV$^{-1}$), for all the plasma regimes encountered in both L1 and L2 orbits. These results set the proton diverter as a mandatory shielding system on board the ATHENA mission and all high throughput X-ray telescopes operating in the interplanetary space. For a magnetic field computed to deflect 99\% of the protons that would otherwise reach the WFI, Geant4 simulations show that this configuration, in the assumption of a uniform field, would efficiently shield the focal plane, yielding a residual background level of the order or below the requirement.

astro-ph.IM

The Wide Field Imager Instrument for Athena

The WFI (Wide Field Imager) instrument is planned to be one of two complementary focal plane cameras on ESA's next X-ray observatory Athena. It combines unprecedented survey power through its large field of view of 40 amin x 40 amin together with excellent count rate capability (larger than 1 Crab). The energy resolution of the silicon sensor is state-of-the-art in the energy band of interest from 0.2 keV to 15 keV, e.g. the full width at half maximum of a line at 7 keV will be better than 170 eV until the end of the nominal mission phase. This performance is accomplished by using DEPFET active pixel sensors with a pixel size of 130 x 130 microns is well suited to the on-axis angular resolution of 5 arcsec half energy width (HEW) of the mirror system. Each DEPFET pixel is a combined sensor-amplifier structure with a MOSFET integrated onto a fully depleted 450 micron thick silicon bulk. Two detectors are planned for the WFI instrument: A large-area detector comprising four sensors with a total of 1024 x 1024 pixels and a fast detector optimized for high count rate observations. This high count rate capable detector permits for bright point sources with an intensity of 1 Crab a throughput of more than 80% and a pile-up of less than 1 %. The fast readout of the DEPFET pixel matrices is facilitated by an ASIC development, called VERITAS-2. Together with the Switcher-A, a control ASIC that allows for operation of the DEPFET in rolling shutter mode, these elements form the key components of the WFI detectors. The detectors are surrounded by a graded-Z shield, which has in particular the purpose to avoid fluorescence lines that would contribute to the instrument background...[Abridged]

astro-ph.IM

Athena Wide Field Imager Key Science Drivers

The Wide Field Imager (WFI) is one of two instruments for the Advanced Telescope for High-ENergy Astrophysics (Athena). In this paper we summarise three of the many key science objectives for the WFI - the formation and growth of supermassive black holes, non-gravitational heating in clusters of galaxies, and spin measurements of stellar mass black holes - and describe their translation into the science requirements and ultimately instrument requirements. The WFI will be designed to provide excellent point source sensitivity and grasp for performing wide area surveys, surface brightness sensitivity, survey power, and absolute temperature and density calibration for in-depth studies of the outskirts of nearby clusters of galaxies and very good high-count rate capability, throughput, and low pile-up, paired with very good spectral resolution, for detailed explorations of bright Galactic compact objects.

astro-ph.IM

eROSITA on SRG

eROSITA (extended ROentgen Survey with an Imaging Telescope Array) is the core instrument on the Russian Spektrum-Roentgen-Gamma (SRG) mission which is scheduled for launch in late 2012. eROSITA is fully approved and funded by the German Space Agency DLR and the Max-Planck-Society.The design driving science is the detection of 50-100 thousands Clusters of Galaxies up to redshift z~1.3 in order to study the large scale structure in the Universe and test cosmological models, especially Dark Energy. This will be accomplished by an all-sky survey lasting for four years plus a phase of pointed observations. eROSITA consists of seven Wolter-I telescope modules, each equipped with 54 Wolter-I shells having an outer diameter of 360 mm. This would provide and effective area at 1.5 keV of ~1500 cm2 and an on axis PSF HEW of 15" which would provide an effective angular resolution of 25"-30". In the focus of each mirror module, a fast frame-store pn-CCD will provide a field of view of 1deg in diameter for an active FOV of ~0.83 deg2. At the time of writing the instrument development is currently in phase C/D.

astro-ph.CO

Improving XMM-Newton EPIC pn data at low energies: method and application to the Vela SNR

High quantum efficiency over a broad spectral range is one of the main properties of the EPIC pn camera on-board XMM-Newton. The quantum efficiency rises from ~75% at 0.2 keV to ~100% at 1 keV, stays close to 100% until 8 keV, and is still ~90% at 10 keV. The EPIC pn camera is attached to an X-ray telescope which has the highest collecting area currently available, in particular at low energies (more than 1400 cm2 between 0.1 and 2.0 keV). Thus, this instrument is very sensitive to the low-energy X-ray emission. However, X-ray data at energies below ~0.2 keV are considerably affected by detector effects, which become more and more important towards the lowest transmitted energies. In addition to that, pixels which have received incorrect offsets during the calculation of the offset map at the beginning of each observation, show up as bright patches in low-energy images. Here we describe a method which is not only capable of suppressing the contaminations found at low energies, but which also improves the data quality throughout the whole EPIC pn spectral range. This method is then applied to data from the Vela supernova remnant.

astro-ph