SearcharxivSearch

arXiv subjects

O. Cip

Publications and source records attributed to O. Cip.

2 recordsLinked to original sources

A thorium-229 optical nuclear clock with feedback loop

The laser-accessible nuclear transition in the thorium-229 isotope has been identified as a promising candidate for the realization of an optical nuclear clock. Such a nuclear clock might rival or outperform current optical clocks based on electron-shell transitions in atoms or ions, is expected to be more robust against external perturbations, and provides enhanced sensitivity in clock-based tests of fundamental principles of physics. Here, we implement a thorium-229 nuclear clock by stabilizing a continuous-wave laser to the 148 nm nuclear transition with rapid feedback based on continuous absorption spectroscopy. The thorium-229 nuclei are embedded into a millimeter-sized, room temperature calcium fluoride crystal. A subharmonic of the 148 nm radiation is continuously compared to a Yb+ single-ion clock. The nuclear clock shows a simple shot-noise limited scaling of the fractional frequency instability of $3\cdot 10^{-12} \sqrt{\tau/\text{s}}$ where $\tau$ is the averaging time, approaching $10^{-15}$ instabilities over 1 day of continuous operation. Improvements of the instability by several orders of magnitude can be projected for future solid-state nuclear clocks. We use the nuclear clock to constrain models of ultralight dark matter by searching for periodic fluctuations and slow drifts in the nuclear transition energy, on time scales between 20 s and 1 day. Drawing benefit from the enhanced sensitivity of the thorium-229 transition, these constraints compete with the best atomic clocks concerning dark matter coupling to photons and go beyond previous measurements regarding coupling to the strong force and quarks.

physics.atom-ph

Automatic unit for measuring refractive index of air based on Ciddor equation and its verification using direct interferometric measurement method

In scanning probe microscopy laser interferometers are usually used for measuring the position of the probe tip with a metrological traceability. As the most of the AFM setups are designed to work under standard atmospheric conditions the changes of the refractive index of air have an influence to measured values of the length with 1.0e-4 relatively. In order to achieve better accuracies the refractive index of air has to be monitored continuously and its instantaneous value has to be used for compensating the lengths measured by all of the interferometric axes. In the presented work we developed a new concept of an electronic unit which is able to monitor the refractive index of air on basis of measurement of ambient atmospheric conditions: temperature, humidity, pressure of the air and the CO2 concentration. The data processing is based on Ciddor equation for calculating the refractive index of air. The important advantage of the unit is a very low power consumption of the electronics so the unit causes only negligible temperature effects to the measured environment. The accuracy of the indirect measuring method employed by the unit was verified. We tested the accuracy in comparison with a direct method of measuring refractive index of air based on an evacuatable cell placed at the measuring arm of a laser interferometer. An experimental setup used for verification is presented together with a set of measurements describing the performance. The resulting accuracy of the electronic unit falls to the 4.1e-7 relatively.

physics.ins-det