SearcharxivSearch

arXiv subjects

O. Kyzylova

Publications and source records attributed to O. Kyzylova.

At least 19 recordsLinked to original sources

Measurement of coherent elastic neutrino nucleus scattering on germanium by COHERENT

The COHERENT collaboration reports the most precise measurement of the coherent elastic neutrino-nucleus scattering cross section to date. This measurement was performed with COHERENT's germanium detector array, Ge-Mini, at the Spallation Neutron Source at Oak Ridge National Laboratory. A cumulative exposure of $4.68\times10^{22}$ protons on target yielded a total number of observed counts of $124^{+14}_{-12}$ and a flux-averaged cross section of $1.00 \pm 0.10 \mathrm{(statistical)} \pm 0.10 \mathrm{(systematic)}$ relative to the standard-model expectation of $5.9\times10^{-39} \mathrm{cm}^2$. The well-understood energy and timing distributions of the neutrino source allow for independent measurements of muon- and electron-neutrino scattering rates. This information is used to improve constraints on non-standard neutrino interactions mediated by heavy particles.

hep-ex

The COHERENT Experiment: 2026 Update

The COHERENT experiment measures neutrino-induced recoils from coherent elastic neutrino-nucleus scattering (CEvNS) with multiple nuclear targets at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), USA. Several successful CEvNS measurements have been achieved in recent years with tens-of-kg detector masses, with a CsI scintillating crystal, a liquid argon single-phase detector, and high-purity germanium spectrometers. For the next phase, COHERENT aims at high-statistics detection of CEvNS events for precision tests of the standard model of particle physics, and to probe new physics beyond-the-standard model. Percent-level precision can be achieved by lowering thresholds, reducing backgrounds, and by scaling up the detector masses. It goes hand in hand with benchmarking the neutrino flux from the SNS. Further detectors will measure CEvNS in additional nuclei, including lighter target nuclei such as sodium and neon, to continue to test the expected neutron-number-squared dependence of the cross section. COHERENT can furthermore study charged-current and neutral-current inelastic neutrino-nucleus cross sections on various nuclei at neutrino energies below $\sim$50 MeV. Many of these cross sections have never been measured before, but are critical input for the interpretation of core-collapse supernova detection in large-scale neutrino experiments such as DUNE, Super-K, Hyper-K, and HALO.

hep-ex

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT's Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe a on-beam excess of 20.6 +7.1 -6.3 counts with a total exposure of 10.22 GWhkg and we reject the no-CEvNS hypothesis with 3.9 sigma significance. The result agrees with the predicted standard model of particle physics signal rate within 2 sigma.

hep-ex

A prototype reactor-antineutrino detector based on $^6$Li-doped pulse-shaping-discriminating plastic scintillator

An aboveground 60-kg reactor-antineutrino detector prototype, comprised of a 2-dimensional array of 36 $^{6}$Li-doped pulse shape sensitive plastic scintillator bars, is described. Each bar is 50~cm long with a square cross section of 5.5~cm. Doped with $^{6}$Li at 0.1\% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-beta-decay reaction. Each bar is wrapped with a specular reflector that directs photons towards PMTs mounted at both ends of the bar. This paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as PSD, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.

physics.ins-det

Measurement of the Electron-Neutrino Charged-Current Cross Sections on ${}^{127}$I with the COHERENT NaI$ν$E detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ${}^{127}$I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy ($\leq$ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of $9.2^{+2.1}_{-1.8} \times 10^{-40}$ cm$^2$. This corresponds to a value that is $\sim$41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on $^{127}$I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be $5.2^{+3.4}_{-3.1} \times 10^{-40}$ and $2.2^{+3.5}_{-2.2} \times 10^{-40}$ cm$^2$, respectively.

nucl-ex

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several beyond-the-standard-model scenarios such as neutrino non-standard interactions and accelerator-produced dark matter. This detector's performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of CsI nuclei and detection of neutrinos from a core-collapse supernova.

hep-ex

Measurement of ${}^{nat}$Pb($ν_e$,X$n$) production with a stopped-pion neutrino source

Using neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL), the COHERENT collaboration has studied the Pb($ν_e$,X$n$) process with a lead neutrino-induced-neutron (NIN) detector. Data from this detector are fit jointly with previously collected COHERENT data on this process. A combined analysis of the two datasets yields a cross section that is $0.29^{+0.17}_{-0.16}$ times that predicted by the MARLEY event generator using experimentally-measured Gamow-Teller strength distributions, consistent with no NIN events at 1.8$σ$. This is the first inelastic neutrino-nucleus process COHERENT has studied, among several planned exploiting the high flux of low-energy neutrinos produced at the SNS.

hep-ex

Final Measurement of the U235 Antineutrino Energy Spectrum with the PROSPECT-I Detector at HFIR

This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely U235-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. The reconstructed energy spectrum is unfolded into antineutrino energy and compared with both the Huber-Mueller model and a spectrum from a commercial reactor burning multiple fuel isotopes. A local excess over the model is observed in the 5MeV to 7MeV energy region. Comparison of the PROSPECT results with those from commercial reactors provides new constraints on the origin of this excess, disfavoring at 2.2 and 3.2 standard deviations the hypotheses that antineutrinos from U235 are solely responsible and non-contributors to the excess observed at commercial reactors respectively.

nucl-ex

PROSPECT-II Physics Opportunities

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum from $^{235}$U, and demonstrated the observation of reactor antineutrinos in an aboveground detector with good energy resolution and well-controlled backgrounds. The PROSPECT collaboration is now preparing an upgraded detector, PROSPECT-II, to probe yet unexplored parameter space for sterile neutrinos and contribute to a full resolution of the Reactor Antineutrino Anomaly, a longstanding puzzle in neutrino physics. By pressing forward on the world's most precise measurement of the $^{235}$U antineutrino spectrum and measuring the absolute flux of antineutrinos from $^{235}$U, PROSPECT-II will sharpen a tool with potential value for basic neutrino science, nuclear data validation, and nuclear security applications. Following a two-year deployment at HFIR, an additional PROSPECT-II deployment at a low enriched uranium reactor could make complementary measurements of the neutrino yield from other fission isotopes. PROSPECT-II provides a unique opportunity to continue the study of reactor antineutrinos at short baselines, taking advantage of demonstrated elements of the original PROSPECT design and close access to a highly enriched uranium reactor core.

hep-ex

Physics Opportunities with PROSPECT-II

The PROSPECT experiment has substantially addressed the original 'Reactor Antineutrino Anomaly' by performing a high-resolution spectrum measurement from an enriched compact reactor core and a reactor model-independent sterile neutrino oscillation search based on the unique spectral distortions the existence of eV$^2$-scale sterile neutrinos would impart. But as the field has evolved, the current short-baseline (SBL) landscape supports many complex phenomenological interpretations, establishing a need for complementary experimental approaches to resolve the situation. While the global suite of SBL reactor experiments, including PROSPECT, have probed much of the sterile neutrino parameter space, there remains a large region above 1 eV$^2$ that remains unaddressed. Recent results from BEST confirm the Gallium Anomaly, increasing its significance to $\sim 5σ$, with sterile neutrinos providing a possible explanation of this anomaly. Separately, the MicroBooNE exclusion of electron-like signatures causing the MiniBooNE low-energy excess does not eliminate the possibility of sterile neutrinos as an explanation. Focusing specifically on the future use of reactors as a neutrino source for beyond-the-standard-model physics and applications, higher-precision spectral measurements still have a role to play. These recent results have created a confusing landscape which requires new data to disentangle the seemingly contradictory measurements. To directly probe $\overlineν_{e}$ disappearance from high $Δm^2$ sterile neutrinos, the PROSPECT collaboration proposes to build an upgraded and improved detector, PROSPECT-II. It features an evolutionary detector design which can be constructed and deployed within one year and have impactful physics with as little as one calendar year of data.

hep-ex

Joint Determination of Reactor Antineutrino Spectra from $^{235}$U and $^{239}$Pu Fission by Daya Bay and PROSPECT

A joint determination of the reactor antineutrino spectra resulting from the fission of $^{235}$U and $^{239}$Pu has been carried out by the Daya Bay and PROSPECT collaborations. This Letter reports the level of consistency of $^{235}$U spectrum measurements from the two experiments and presents new results from a joint analysis of both data sets. The measurements are found to be consistent. The combined analysis reduces the degeneracy between the dominant $^{235}$U and $^{239}$Pu isotopes and improves the uncertainty of the $^{235}$U spectral shape to about 3\%. The ${}^{235}$U and $^{239}$Pu antineutrino energy spectra are unfolded from the jointly deconvolved reactor spectra using the Wiener-SVD unfolding method, providing a data-based reference for other reactor antineutrino experiments and other applications. This is the first measurement of the $^{235}$U and $^{239}$Pu spectra based on the combination of experiments at low- and highly enriched uranium reactors.

nucl-ex

Limits on Sub-GeV Dark Matter from the PROSPECT Reactor Antineutrino Experiment

If dark matter has mass lower than around 1 GeV, it will not impart enough energy to cause detectable nuclear recoils in many direct-detection experiments. However, if dark matter is upscattered to high energy by collisions with cosmic rays, it may be detectable in both direct-detection experiments and neutrino experiments. We report the results of a dedicated search for boosted dark matter upscattered by cosmic rays using the PROSPECT reactor antineutrino experiment. We show that such a flux of upscattered dark matter would display characteristic diurnal sidereal modulation, and use this to set new experimental constraints on sub-GeV dark matter exhibiting large interaction cross-sections.

hep-ex

Joint Measurement of the $^{235}$U Antineutrino Spectrum by Prospect and Stereo

The PROSPECT and STEREO collaborations present a combined measurement of the pure $^{235}$U antineutrino spectrum, without site specific corrections or detector-dependent effects. The spectral measurements of the two highest precision experiments at research reactors are found to be compatible with $χ^2/\mathrm{ndf} = 24.1/21$, allowing a joint unfolding of the prompt energy measurements into antineutrino energy. This $\barν_e$ energy spectrum is provided to the community, and an excess of events relative to the Huber model is found in the 5-6 MeV region. When a Gaussian bump is fitted to the excess, the data-model $χ^2$ value is improved, corresponding to a $2.4σ$ significance.

nucl-ex

Improved Short-Baseline Neutrino Oscillation Search and Energy Spectrum Measurement with the PROSPECT Experiment at HFIR

We present a detailed report on sterile neutrino oscillation and U-235 antineutrino energy spectrum measurement results from the PROSPECT experiment at the highly enriched High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. In 96 calendar days of data taken at an average baseline distance of 7.9 m from the center of the 85 MW HFIR core, the PROSPECT detector has observed more than 50,000 interactions of antineutrinos produced in beta decays of U-235 fission products. New limits on the oscillation of antineutrinos to light sterile neutrinos have been set by comparing the detected energy spectra of ten reactor-detector baselines between 6.7 and 9.2 meters. Measured differences in energy spectra between baselines show no statistically significant indication of antineutrinos to sterile neutrino oscillation and disfavor the Reactor Antineutrino Anomaly best-fit point at the 2.5$σ$ confidence level. The reported U-235 antineutrino energy spectrum measurement shows excellent agreement with energy spectrum models generated via conversion of the measured U-235 beta spectrum, with a $χ^2$/DOF of 31/31. PROSPECT is able to disfavor at 2.4$σ$ confidence level the hypothesis that U-235 antineutrinos are solely responsible for spectrum discrepancies between model and data obtained at commercial reactor cores. A data-model deviation in PROSPECT similar to that observed by commercial core experiments is preferred with respect to no observed deviation, at a 2.2$σ$ confidence level.

hep-ex

Note on arXiv:2005.05301, 'Preparation of the Neutrino-4 experiment on search for sterile neutrino and the obtained results of measurements'

We comment on the claimed observation [arXiv:arXiv:2005.05301] of sterile neutrino oscillations by the Neutrino-4 collaboration. Such a claim, which requires the existence of a new fundamental particle, demands a level of rigor commensurate with its impact. The burden lies with the Neutrino-4 collaboration to provide the information necessary to prove the validity of their claim to the community. In this note, we describe aspects of both the data and analysis method that might lead to an oscillation signature arising from a null experiment and describe additional information needed from the Neutrino-4 collaboration to support the oscillation claim. Additionally, as opposed to the assertion made by the Neutrino-4 collaboration, we also show that the method of 'coherent summation' using the $L/E$ parameter produces similar results to the methods used by the PROSPECT and the STEREO collaborations.

hep-ex

Nonfuel Antineutrino Contributions in the High Flux Isotope Reactor

Reactor neutrino experiments have seen major improvements in precision in recent years. With the experimental uncertainties becoming lower than those from theory, carefully considering all sources of $\overlineν_{e}$ is important when making theoretical predictions. One source of $\overlineν_{e}$ that is often neglected arises from the irradiation of the nonfuel materials in reactors. The $\overlineν_{e}$ rates and energies from these sources vary widely based on the reactor type, configuration, and sampling stage during the reactor cycle and have to be carefully considered for each experiment independently. In this article, we present a formalism for selecting the possible $\overlineν_{e}$ sources arising from the neutron captures on reactor and target materials. We apply this formalism to the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, the $\overlineν_{e}$ source for the the Precision Reactor Oscillation and Spectrum Measurement (PROSPECT) experiment. Overall, we observe that the nonfuel $\overlineν_{e}$ contributions from HFIR to PROSPECT amount to 1\% above the inverse beta decay threshold with a maximum contribution of 9\% in the 1.8--2.0~MeV range. Nonfuel contributions can be particularly high for research reactors like HFIR because of the choice of structural and reflector material in addition to the intentional irradiation of target material for isotope production. We show that typical commercial pressurized water reactors fueled with low-enriched uranium will have significantly smaller nonfuel $\overlineν_{e}$ contribution.

nucl-ex

The PROSPECT Reactor Antineutrino Experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented $^6$Li-doped liquid scintillator detector for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT is a movable 4-ton antineutrino detector covering distances of 7m to 13m from the High Flux Isotope Reactor core. It will probe the best-fit point of the $\barν_e$ disappearance experiments at 4$σ$ in 1 year and the favored regions of the sterile neutrino parameter space at more than 3$σ$ in 3 years. PROSPECT will test the origin of spectral deviations observed in recent $θ_{13}$ experiments, search for sterile neutrinos, and address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly. This paper describes the design, construction, and commissioning of PROSPECT and reports first data characterizing the performance of the PROSPECT antineutrino detector.

physics.ins-det

The Radioactive Source Calibration System of the PROSPECT Reactor Antineutrino Detector

The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at the High Flux Isotope Reactor in Oak Ridge National Laboratory. Antineutrino events are identified via inverse beta decay and read out by photomultiplier tubes located at the ends of each segment. The detector response is characterized using a radioactive source calibration system. This paper describes the design, operation, and performance of the PROSPECT source calibration system.

physics.ins-det