O. Maev

Publications and source records attributed to O. Maev.

7 recordsLinked to original sources

Proposal on Application of the Multi-Wire Proportional Chambers of the LHCb MUON Detector at Very High Rates for the Future Upgrades

The MUON Detector (MD) of LHCb is one of the largest instruments of this kind worldwide, and one of the most irradiated. It has performed exceptionally well during the RUN1 and RUN2 of the LHC at an instantaneous luminosity of 4$\times$10$^{32}$ cm$^{-2}$s$^{-1}$, with tracking inefficiencies at the level of 1$\%$ and 2.6$\%$, respectively. Looking forward for the future LHCb Upgrade 2 (U2) planned in 2031 and aiming in running the detector at increased luminosity by a factor $\sim$50, and at the same time keeping a very high ($\sim$99$\%$) detection efficiency, an option with reuse significant part of the present Multi-Wire Proportional Chambers (MWPC) in a new Muon System is presented. In addition, the first idea of new Front End Electronics (FEE) and an existing test setup applicable for designing both: new MWPCs with a higher granularity of the cathode readout pads and new FEE are described.

physics.ins-det

Long-term Operation of the Multi-Wire-Proportional-Chambers of the LHCb Muon System

The muon detector of LHCb, which comprises 1368 multi-wire-proportional-chambers (MWPC) for a total area of 435 m2, is the largest instrument of its kind exposed to such a high-radiation environment. In nine years of operation, from 2010 until 2018, we did not observe appreciable signs of ageing of the detector in terms of reduced performance. However, during such a long period, many chamber gas gaps suffered from HV trips. Most of the trips were due to Malter-like effects, characterised by the appearance of local self-sustained high currents, presumably originating from impurities induced during chamber production. Very effective, though long, recovery procedures were implemented with a HV training of the gaps in situ while taking data. The training allowed most of the affected chambers to be returned to their full functionality and the muon detector efficiency to be kept close to 100%. The possibility of making the recovery faster and even more effective by adding a small percentage of oxygen in the gas mixture has been studied and successfully tested.

physics.ins-det

Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency

A method is described which allows to deduce the dead-time of the front-end electronics of the LHCb muon detector from a series of measurements performed at different luminosities at a bunch-crossing rate of 20 MHz. The measured values of the dead-time range from 70 ns to 100 ns. These results allow to estimate the performance of the muon detector at the future bunch-crossing rate of 40 MHz and at higher luminosity.

physics.ins-det

Performance of the Muon Identification at LHCb

The performance of the muon identification in LHCb is extracted from data using muons and hadrons produced in J/ψ->μμ, Λ->pπand D^{\star}->πD0(Kπ) decays. The muon identification procedure is based on the pattern of hits in the muon chambers. A momentum dependent binary requirement is used to reduce the probability of hadrons to be misidentified as muons to the level of 1%, keeping the muon efficiency in the range of 95-98%. As further refinement, a likelihood is built for the muon and non-muon hypotheses. Adding a requirement on this likelihood that provides a total muon efficiency at the level of 93%, the hadron misidentification rates are below 0.6%.

physics.ins-det

A new method based on noise counting to monitor the frontend electronics of the LHCb muon detector

A new method has been developed to check the correct behaviour of the frontend electronics of the LHCb muon detector. This method is based on the measurement of the electronic noise rate at different thresholds of the frontend discriminator. The method was used to choose the optimal discriminator thresholds. A procedure based on this method was implemented in the detector control system and allowed the detection of a small percentage of frontend channels which had deteriorated. A Monte Carlo simulation has been performed to check the validity of the method.

physics.ins-det

Performance of the LHCb muon system

The performance of the LHCb Muon system and its stability across the full 2010 data taking with LHC running at ps = 7 TeV energy is studied. The optimization of the detector setting and the time calibration performed with the first collisions delivered by LHC is described. Particle rates, measured for the wide range of luminosities and beam operation conditions experienced during the run, are compared with the values expected from simulation. The space and time alignment of the detectors, chamber efficiency, time resolution and cluster size are evaluated. The detector performance is found to be as expected from specifications or better. Notably the overall efficiency is well above the design requirements

physics.ins-det

Performance of the LHCb muon system with cosmic rays

The LHCb Muon system performance is presented using cosmic ray events collected in 2009. These events allowed to test and optimize the detector configuration before the LHC start. The space and time alignment and the measurement of chamber efficiency, time resolution and cluster size are described in detail. The results are in agreement with the expected detector performance.

physics.ins-det