SearcharxivSearch

arXiv subjects

O. Melnychuk

Publications and source records attributed to O. Melnychuk.

18 recordsLinked to original sources

Excellent performance of 650 MHz single-cell niobium cavity after electropolishing

Electropolishing process and cathodes have undergone modification and optimization for both low- and high-beta 650 MHz five-cell niobium cavities for PIP-II. Cavities treated with these modified electropolishing conditions exhibited smooth surfaces and good performance in baseline tests. Nonetheless, due to administrative constraints on project cavities, maximum gradient performance testing was not conducted. This paper presents a study conducted on a single-cell 650 MHz cavity utilizing the optimized electropolishing conditions, highlighting the maximum performance attained for this specific cavity. The cavity tested at 2 K in a vertical cryostat reached a superior accelerating field gradient of 53.3 MV/m at Q0 of 1.6x1010, which is the highest gradient attained for this type of large-sized cavities.

physics.acc-ph

Latest Development of Electropolishing Optimization for 650 MHz Niobium Cavity

Electropolishing (EP) of 1.3 GHz niobium superconducting RF cavities is conducted to achieve a desired smooth and contaminant-free surface that yields good RF performance. Achieving a smooth surface of a large-sized elliptical cavity with the standard EP conditions was found to be challenging. This work aimed to conduct a systematic parametric EP study to understand the effects of various EP parameters on the surface of 650 MHz niobium cavities used in the Proton Improvement Plan-II (PIP-II) linear accelerator. Parameters optimized in this study provided a smooth surface of the cavities. The electropolished cavity showed significantly a higher accelerating gradient meeting baseline requirement and qualified for further surface treatment to improve the cavity quality factor.

physics.acc-ph

Advanced surface treatments for medium-velocity superconducting RF cavities for high accelerating gradient continuous-wave operation

Nitrogen-doping and furnace-baking are advanced high-Q0 recipes developed for 1.3 GHz TESLA-type cavities. These treatments will significantly benefit the high-Q0 linear accelerator community if they can be successfully adapted to different cavity styles and frequencies. Strong frequency- and geometry- dependence of these recipes makes the technology transfer amongst different cavity styles and frequencies far from straightforward, and requires rigorous study. Upcoming high-Q0 continuous-wave linear accelerator projects, such as the proposed Michigan State University Facility for Rare Isotope Beam Energy Upgrade, and the underway Fermilab's Proton Improvement Plan-II, could benefit enormously from adapting these techniques to their beta_opt = 0.6 ~650 MHz 5-cell elliptical superconducting rf cavities, operating at an accelerating gradient of around ~17 MV/m. This is the first investigation of the adaptation of nitrogen doping and medium temperature furnace baking to prototype 644 MHz beta_opt = 0.65 cavities, with the aim of demonstrating the high-Q0 potential of these recipes in these novel cavities for future optimization as part of the FRIB400 project R&D. We find that nitrogen-doping delivers superior Q0, despite the sub-GHz operating frequency of these cavities, but is sensitive to the post-doping electropolishing removal step and experiences elevated residual resistance. Medium temperature furnace baking delivers reasonable performance with decreased residual resistance compared to the nitrogen doped cavity, but may require further recipe refinement. The gradient requirement for the FRIB400 upgrade project is comfortably achieved by both recipes.

physics.acc-ph

Testing of the 2.6 GHz SRF Cavity Tuner for the Dark Photon Experiment at 2 K

At FNAL two single cell 2.6 GHz SRF cavities are being used to search for dark photons, the experiment can be conducted at 2 K or in a dilution refrigerator. Precise frequency tuning is required for these two cavities so they can be matched in frequency. A cooling capacity constraint on the dilution refrigerator only allows piezo actuators to be part of the design of the 2.6 GHz cavity tuner. The tuner is equipped with three encapsulated piezos that deliver long and short-range frequency tuning. Modifications were implemented on the first tuner design due to the low forces on the piezos caused by the cavity. Three brass rods with Belleville washers were added to the design to increase the overall force on the piezos. The testing results at 2 K are presented with the original design tuner and with the modification.

physics.acc-ph

PI Loop Resonance Control for Dark Photon Experiment at 2 K Using a 2.6 GHz SRF Cavity

Two 2.6 GHz SRF cavities are being used for a dark photon search at the vertical test stand (VTS) in FNAL, for the second phase of the Dark SRF experiment. During testing at 2 K the cavities experience frequency detuning caused by microphonics and slow frequency drifts. The experiment requires that the two cavities have the same frequency within the cavity's bandwidth. These two cavities are equipped with frequency tuners consisting of three piezo actuators. The piezo actuators are used for fine-fast frequency tuning. A proportional-integral (PI) loop utilizing the three piezos on the emitter was used to stabilize the cavity frequency and match the receiver cavity frequency. The results from this implementation will be discussed. The integration time was also calculated via simulation.

physics.acc-ph

Flux Expulsion and Material Properties of Niobium Explored in 644-650 MHz Cavities

Upcoming projects requiring high-Q ~650 MHz medium-to-high-$β$ elliptical cavities drive a need to understand magnetic RF loss mechanisms and mitigations in greater detail. High-temperature annealing and fast-cooldowns have proven effective techniques for promoting magnetic flux expulsion in cavities, however the extent of their effectiveness has been observed to vary between niobium material lot and vendor. We explore the fast-cooldown method, and high-temperature annealing (900°C) in 644-650 MHz cavities fabricated from two different niobium vendors: Tokyo-Denkai, and Ningxia. which promote flux-expulsion efficiency. Using EBSD and PPMS methods, we aim to trace cavity flux expulsion efficiency to specific, measurable properties of the bulk niobium material, which, if identified, can lead to methods by which the flux expulsion properties of Nb material can be predicted prior to cavity fabrication, and can enable fine-tuning of cavity temperature treatments.

physics.acc-ph

Q-factor optimization for high-beta 650 MHz cavities for PIP-II

High Q-factors are of utmost importance to minimize losses of superconducting radio-frequency cavities deployed in continuous wave particle accelerators. This study elucidates the surface treatment that can maximize the Q-factors in high-beta 650 MHz elliptical niobium cavities. State-of-the-art surface treatments are applied in many single-cell cavities, and surface resistance studies are performed to understand the microwave dissipation at this unexplored frequency. The nitrogen doping treatment is confirmed to be necessary to maximize the Q-factors at medium RF fields. We applied this treatment in five-cell high-beta 650 MHz cavities and demonstrated that extremely high Q-factors were obtained at medium RF fields with this treatment. We also demonstrated that adding a cold electropolishing step after N-doping is crucial to push the quench field of multicell cavities to higher gradients.

physics.acc-ph

Accelerating fields up to 49 MV/m in TESLA-shape superconducting RF niobium cavities via 75C vacuum bake

In this paper we present the discovery of a new surface treatment applied to superconducting radio frequency (SRF) niobium cavities, leading to unprecedented accelerating fields of 49 MV/m in TESLA-shaped cavities, in continuous wave (CW); the corresponding peak magnetic fields are the highest ever measured in CW, about 210 mT. For TESLA-shape cavities the maximum quench field ever achieved was ~45 MV/m - reached very rarely- with most typical values being below 40 MV/m. These values are reached for niobium surfaces treated with electropolishing followed by the so called mild bake, a 120C vacuum bake (for 48 hours for fine grain and 24 hours for large grain surfaces). We discover that the addition during the mild bake of a step at 75C for few hours, before the 120C, increases systematically the quench fields up to unprecedented values of 49 MV/m. The significance of the result lays not only in the relative improvement, but in the proof that niobium surfaces can sustain and exceed CW radio frequency magnetic fields much larger than Hc1, pointing to an extrinsic nature of the current field limitations, and therefore to the potential to reach accelerating fields well beyond the current state of the art.

physics.acc-ph

The Effect of Mechanical Cold Work on the Magnetic Flux Expulsion of Niobium

Expulsion of ambient flux has been shown to be crucial to obtain high quality factors in bulk niobium SRF cavities. However, there remain many questions as to what properties of the niobium material determine its flux expulsion behavior. In this paper, we present first results from a new study of two cavities that were specially fabricated to study flux expulsion. Both cavities were made from large grain ingot niobium slices, one of which had its slices rolled prior to fabrication, and none these slices were annealed prior to measurement. Expulsion measurements indicate that a dense network of grain boundaries is not necessary for a cavity to have near-complete flux trapping behavior up to large thermal gradients. The results also contribute to a body of evidence that cold work is a strong determinant of flux expulsion behavior in SRF-grade niobium.

physics.acc-ph

Advancement in the understanding of the field and frequency dependent microwave surface resistance of niobium

The radio-frequency surface resistance of niobium resonators is incredibly reduced when nitrogen impurities are dissolved as interstitial in the material, conferring ultra-high Q-factors at medium values of accelerating field. This effect has been observed in both high and low temperature nitrogen treatments. As a matter of fact, the peculiar anti Q-slope observed in nitrogen doped cavities, i.e. the decreasing of the Q-factor with the increasing of the radio-frequency field, come from the decreasing of the BCS surface resistance component as a function of the field. Such peculiar behavior has been considered consequence of the interstitial nitrogen present in the niobium lattice after the doping treatment. The study here presented show the field dependence of the BCS surface resistance of cavities with different resonant frequencies, such as: 650 MHz, 1.3 GHz, 2.6 GHz and 3.9 GHz, and processed with different state-of-the-art surface treatments. These findings show for the first time that the anti Q-slope might be seen at high frequency even for clean Niobium cavities, revealing useful suggestion on the physics underneath the anti Q-slope effect.

physics.acc-ph

Quench-Induced Degradation of the Quality Factor in Superconducting Resonators

Quench of superconducting radio-frequency cavities frequently leads to the lowered quality factor Q0, which had been attributed to the additional trapped magnetic flux. Here we demonstrate that the origin of this magnetic flux is purely extrinsic to the cavity by showing no extra dissipation (unchanged Q0) after quenching in zero magnetic field, which allows us to rule out intrinsic mechanisms of flux trapping such as generation of thermal currents or trapping of the rf field. We also show the clear relation of dissipation introduced by quenching to the orientation of the applied magnetic field and the possibility to fully recover the quality factor by requenching in the compensated field. We discover that for larger values of the ambient field, the Q-factor degradation may become irreversible by this technique, likely due to the outward flux migration beyond the normal zone opening during quench. Our findings are of special practical importance for accelerators based on low- and medium-beta accelerating structures residing close to focusing magnets, as well as for all high-Q cavity-based accelerators.

physics.acc-ph

Efficient expulsion of magnetic flux in superconducting RF cavities for high $Q_0$ applications

Even when cooled through its transition temperature in the presence of an external magnetic field, a superconductor can expel nearly all external magnetic flux. This Letter presents an experimental study to identify the parameters that most strongly influence flux trapping in high purity niobium during cooldown. This is critical to the operation of superconducting radiofrequency cavities, in which trapped flux degrades the quality factor and therefore cryogenic efficiency. Flux expulsion was measured on a large survey of 1.3 GHz cavities prepared in various ways. It is shown that both spatial thermal gradient and high temperature treatment are critical to expelling external magnetic fields, while surface treatment has minimal effect. For the first time, it is shown that a cavity can be converted from poor expulsion behavior to strong expulsion behavior after furnace treatment, resulting in a substantial improvement in quality factor. Future plans are described to build on this result in order to optimize treatment for future cavities.

physics.acc-ph

Magnetic Flux Dynamics in Horizontally Cooled Superconducting Cavities

Previous studies on magnetic flux expulsion as a function of cooling details have been performed for superconducting niobium cavities with the cavity beam axis placed parallel respect to the helium cooling flow, and findings showed that for sufficient cooling thermogradients all magnetic flux could be expelled and very low residual resistance could be achieved. In this paper we investigate the flux trapping and its impact on radio frequency surface resistance when the resonators are positioned perpendicularly to the helium cooling flow, which is representative of how superconducting radio-frequency (SRF) cavities are cooled in an accelerator. We also extend the studies to different directions of applied magnetic field surrounding the resonator. Results show that in the cavity horizontal configuration there is a different impact of the various field components on the final surface resistance, and that several parameters have to be considered to understand flux dynamics. A newly discovered phenomenon of concentration of flux lines at the cavity top leading to cavity equator temperature rise is presented.

physics.acc-ph

Ultra-high quality factors in superconducting niobium cavities in ambient magnetic fields up to 190 mG

Ambient magnetic field, if trapped in the penetration depth, leads to the residual resistance and therefore sets the limit for the achievable quality factors in superconducting niobium resonators for particle accelerators. Here we show that a complete expulsion of the magnetic flux can be performed and leads to: 1) record quality factors $Q > 2\times10^{11}$ up to accelerating gradient of 22 MV/m; 2) $Q\sim3\times10^{10}$ at 2 K and 16 MV/m in up to 190 mG magnetic fields. This is achieved by large thermal gradients at the normal/superconducting phase front during the cooldown. Our findings open up a way to ultra-high quality factors at low temperatures and show an alternative to the sophisticated magnetic shielding implemented in modern superconducting accelerators.

physics.acc-ph

Dependence of the residual surface resistance of superconducting RF cavities on the cooling dynamics around $T_\mathrm{c}$

We report a strong effect of the cooling dynamics through $T_\mathrm{c}$ on the amount of trapped external magnetic flux in superconducting niobium cavities. The effect is similar for fine grain and single crystal niobium and all surface treatments including electropolishing with and without 120$^\circ$C baking and nitrogen doping. Direct magnetic field measurements on the cavity walls show that the effect stems from changes in the flux trapping efficiency: slow cooling leads to almost complete flux trapping and higher residual resistance while fast cooling leads to the much more efficient flux expulsion and lower residual resistance.

physics.acc-ph

Nitrogen and argon doping of niobium for superconducting radio frequency cavities: a pathway to highly efficient accelerating structures

We report a surface treatment that systematically improves the quality factor of niobium radio frequency cavities beyond the expected limit for niobium. A combination of annealing in a partial pressure of nitrogen or argon gas and subsequent electropolishing of the niobium cavity surface leads to unprecedented low values of the microwave surface resistance, and an improvement in the efficiency of the accelerating structures up to a factor of 3, reducing the cryogenic load of superconducting cavities for both pulsed and continuous duty cycles. The field dependence of the surface resistance is reversed compared to standardly treated niobium.

physics.acc-ph

Fermilab experience of post-annealing losses in SRF niobium cavities due to furnace contamination and the ways to its mitigation: a pathway to processing simplification and quality factor improvement

We investigate the effect of high temperature treatments followed by only high-pressure water rinse (HPR) of superconducting radio frequency (SRF) niobium cavities. The objective is to provide a cost effective alternative to the typical cavity processing sequence, by eliminating the material removal step post furnace treatment while preserving or improving the RF performance. The studies have been conducted in the temperature range 800-1000C for different conditions of the starting substrate: large grain and fine grain, electro-polished (EP) and centrifugal barrel polished (CBP) to mirror finish. An interesting effect of the grain size on the performances is found. Cavity results and samples characterization show that furnace contaminants cause poor cavity performance, and a practical solution is found to prevent surface contamination. Extraordinary values of residual resistances ~ 1 nOhm and below are then consistently achieved for the contamination-free cavities. These results lead to a more cost-effective processing and improved RF performance, and, in conjunction with CBP, open a potential pathway to acid-free processing.

physics.acc-ph

High Gradient Tests of the Fermilab SSR1 Cavity

In Fermilab we are build and tested several superconducting Single Spoke Resonators (SSR1, β=0.22) which can be used for acceleration of low beta ions. Fist two cavities performed very well during cold test in Vertical Test Station at FNAL. One dressed cavity was also tested successfully in Horizontal Test Station. Currently we are building 8 cavity cryomodule for PIXIE project. Additional 10 cavities were manufactured in the industry and on-going cold test results will be presented in this poster.

physics.acc-ph