SearcharxivSearch

arXiv subjects

O. Missevitch

Publications and source records attributed to O. Missevitch.

4 recordsLinked to original sources

Klein-Gordon equation for electrically charged particles with new energy-momentum operator

We address the Klein-Gordon equation for a spinless charged particle in the presence of an electromagnetic (EM) field, and focus on its known shortcoming, related to the existence of solutions with a negative probability density. We disclose a principal way to overcome this shortcoming, using our recent results obtained in the analysis of quantum phase effects for charges and dipoles, which prove the need to abandon the customary definition of the momentum operator for a charged particle in an EM field through its canonical momentum, and to adopt the more general definition of this operator through the sum of mechanical and electromagnetic momenta for the charged particle in an EM field. We show that the ap-plication of the new energy-momentum operator to the Klein-Gordon equation actually eliminates solutions with negative probability density. Some implications of the obtained results are discussed

physics.gen-ph

Development of CaMoO4 crystal scintillators for double beta decay experiment with 100-Mo

Energy resolution, alpha/beta ratio, pulse-shape discrimination for gamma rays and alpha particles, temperature dependence of scintillation properties, and radioactive contamination were studied with CaMoO4 crystal scintillators. A high sensitivity experiment to search for neutrinoless double beta decay of 100-Mo by using CaMoO4 scintillators is discussed.

nucl-ex

On the Radiation Damage of BTeV EMCAL Detector Unit

Hamamatsu photomultiplier tubes (PMT) and various PMT window materials were exposed to gamma irradiation. Tests were performed with absorbed doses of 1 krad and 120 krad. Initial recommendations on PMT types to use in the BTeV electromagnetic calorimeter are stated.

physics.ins-det

Position-Sensitive Detector with Depth-of-Interaction Determination for Small Animal PET

Crystal arrays made of LSO and LuAP crystals 2x2x10 mm pixels were manufactured for evaluation of detector with depth-of-interaction (DOI) determination capability intended for small animal positron emission tomograph. Position-sensitive LSO/LuAP phoswich DOI detector based on crystal 8x8 arrays and HAMAMATSU R5900-00-M64 position-sensitive multi-anode photomultiplier tube was developed and evaluated. Time resolution was found to be not worse than 1.0 ns FWHM for both layers, and spatial resolution mean value was 1.5 mm FWHM for the center of field-of-view.

physics.ins-det