A simple device for microinjections, manipulations and measurements using an electromorphological chip under microinterferometric control of the interface and membrane processes at the thickness range of 5-1000 nm at different angles

Micromanipulations, perfusions and measurements performed using glass microelectrodes filled with an electrolyte is a conventional technique for experimental morphological and membrane electrophysiological studies at a single cell and membrane surface level. The typical (effective) diameter of the end of the glass microelectrode is from 500 up to less than 100 nm, which prevents one from observing it using a standard optical microscope in accordance with the optical resolution criteria, since the diameter less than 500 nm is indistinguishable within the interference zone. Microprocessor programming of the puller (microforge) that provides pulling and tearing allows to obtain in certain regimes the adjusted diameter and shape of the micropipette tip, although this result is not fully controlled due to the above limitations. In this connection it is necessary to design the control devices for the micropipette tips both at the preparation and operation stages (intracellular or extracellular insertion). This method also should provide visualization of the processes occurring upon interaction of the microelectrode tip with the cell in real time, depending on the electrode type and state, which allows to level the artifacts arising with the systematic error frequency from the uncontrolled operation of the micropipette tip after different ways of the microelectrode filling with the electrolyte. We propose an installation scheme that solves the above problems by means of introducing an interferometric device for microscopic control of the microelectrode and micromanipulator or microperfusor, for the first time for a given type of optical instruments combined with the interferometric optical scheme.

q-bio.SC

Methods of electron microscopy of biological and abiogenic structures in artificial gas atmospheres

This paper reviews opportunities for using electron microscopy in various gas atmospheres for the analysis and morpho-physiological modification of biological structures. The approaches that allow varying the gaseous phase content, as well as temperature, humidity, and pressure, are considered. The applicability of both kinetic and dynamic approaches to the tissue and bioinorganic structure manipulations is pointed out. The possibility of simulation of the beam-induced formation and disintegration of abiogenetic molecular structures is also mentioned as a particular case of the electron beam influence and treatment of the precursor medium in an artificial atmosphere.

physics.ins-det

"MS-Patch-Clamp" or the Possibility of Mass Spectrometry Hybridization with Patch-Clamp Setups for Single Cell Metabolomics and Channelomics

In this projecting work we propose a mass spectrometric patch-clamp equipment with the capillary performing both a local potential registration at the cell membrane and the analyte suction simultaneously. This paper provides a current literature analysis comparing the possibilities of the novel approach proposed with the known methods, such as scanning patch-clamp, scanning ion conductance microscopy, patch clamp based on scanning probe microscopy technology, quantitative subcellular secondary ion mass spectrometry or "ion microscopy", live single-cell mass spectrometry, in situ cell-by-cell imaging, single-cell video-mass spectrometry, etc. We also consider the ways to improve the informativeness of these methods and particularly emphasize the trend at the increasing of the analysis complexity. We propose here the way to improve the efficiency of the cell trapping to the capillary during MS-path-clamp, as well as to provide laser surface ionization using laser trapping and tweezing of cells with the laser beam transmitted through the capillary as a waveguide. It is also possible to combine the above system with the microcolumn separation system or capillary electrophoresis as an optional direction of further development of the complex of analytical techniques emerging from the MS variation of patch-clamp.