Searcharxiv⌕ Search

arXiv subjects

Oleg Komogortsev

Publications and source records attributed to Oleg Komogortsev.

At least 19 recordsLinked to original sources

How Many Persistent Features Does a Biometric Need? A Law Linking Equal Error Rate to Feature Count and Persistence

A biometric designer controls the number of features and their temporal persistence. Earlier empirical work linked the equal error rate (EER) to persistence and to the required number of features by straight lines. We derive the law behind these regularities. For $N$ independent standardized Gaussian features with test-retest correlation $ρ$, scored by cosine similarity, Fisher's $z$-transform turns the genuine and impostor scores into two normals, giving $\mathrm{EER}=Φ(-\frac{1}{2}\sqrt{N}\,\operatorname{atanh}ρ)$ and, inversely, $N=(2q/\operatorname{atanh}ρ)^2$ with $q=Φ^{-1}(1-\mathrm{EER})$; intercorrelated features enter through an effective count $N_{\mathrm{eff}}$. The central extension lets persistence vary across comparisons with spread $τ$ on Fisher's scale: $\mathrm{EER}=Φ(-m/(\sqrt{τ^2+v}+\sqrt{v}))$ with $v=1/(N_{\mathrm{eff}}-2)$, which for a normal spread has a floor $Φ(-m/τ)$ that no number of features can lower. With no fitted parameter the simple law reproduces published simulations and the EER-ICC line, and predicts the KCC-EER relation of eye-movement embeddings on GazeBase ($R^2=0.88$), though less well on GazeBaseVR ($0.63$). Read from the genuine and impostor scores, the general form matches the EER of eye movements, keystroke dynamics, the ECG and face embeddings over 101 conditions with $R^2=0.98$ and a median error of $0.6$ points, against $0.87$ and $1.9$ points for the simple law. The 61 eye-movement, keystroke and ECG conditions check consistency on the same scores; the 40 face conditions use held-out subjects, with the same accuracy. The product $τ\sqrt{N_{\mathrm{eff}}-2}$ gives a design rule: adding or decorrelating features pays fully while it is well below one and little once it exceeds about three, where only higher or more uniform persistence helps.

cs.CV↗

From MNH to the Friedman--Komogortsev Method---which changes improve eye-movement classification?

The Friedman-Komogortsev Method (FKM) is a rule-based classifier of fixations, saccades, and post-saccadic oscillations in 1000-Hz recordings, developed from the modified Nyström-Holmqvist algorithm (MNH) and used in several recent studies. FKM changes MNH in many ways at once: it centres MNH's Savitzky-Golay filter, adds a position-based test for whether an apparent post-saccadic oscillation continues the saccade, adds rejection tests, and changes several thresholds. We asked which of these changes alter agreement with human classification. Both algorithms were scored against twenty 26-s GazeBase reading recordings hand-classified by three trained raters, and each change was reverted in turn. FKM agreed better than MNH as MNH was used: saccade Cohen's kappa rose on all 20 recordings (median +0.034), and saccade boundaries moved from 2-3 ms late to the raters' sample. One change produced this: centring the filter, which removes a three-sample delay. Reinstating the delay returned FKM's saccade kappa to MNH's value, and centring MNH's filter alone made MNH match FKM on saccades and exceed it on post-saccadic events. The position-based test changed how saccades with several velocity peaks were divided, splitting 8% of rater-labelled "wavy" saccades into a saccade and a spurious oscillation against 39% for delay-corrected MNH. FKM's higher post-saccadic velocity floor traded recall for precision. The remaining changes had no measurable effect on these recordings. FKM's improvement over MNH is therefore a filter-alignment correction that MNH users can apply directly, plus a segmentation rule for multi-peak saccades.

q-bio.NC↗

Eye Tracking Signal Quality Evaluation: Meta Quest Pro vs HTC VIVE Pro Eye vs HTC VIVE Focus Vision

Gaze research in virtual reality needs eye trackers of known error. Thirty participants completed the same protocol on the Meta Quest Pro (QP), HTC VIVE Pro Eye (PE) and HTC VIVE Focus Vision (FV); to our knowledge, this is the first evaluation of the FV eye tracker. In a random-saccade task, median participant mean error was 1.04° on QP, 1.50° on PE and 2.41° on FV, which remained least accurate after linear recalibration. In a later block with a darker background, PE error rose by 0.70°. FV samples were positively correlated: dispersion was 9.8 times the sample-to-sample root mean square. The device clocks showed losses that mean error hides. QP paused for up to 6.04 s, and FV skipped single samples. During instructed eye closures, QP flagged every sample valid while gaze moved 9.74°. Evaluations should report repeated timestamps, loss composition on the device clock and validity during eye closures.

cs.HC↗

Gaze Under Strain: How Oculomotor Behavior Tracks Cybersickness Progression in VR

Cybersickness remains a major barrier to comfortable, accessible virtual reality (VR). Arising from mismatches between visual and vestibular signals, it places sustained demands on gaze stabilization and visual processing. Because gaze is the mechanism through which users actively sample the virtual environment, cybersickness-induced disruptions may alter both what users perceive and how discomfort itself emerges. Yet, how eye-movement behavior evolves alongside discomfort during prolonged VR exposure remains poorly understood. We present a behavioral analysis of eye-tracking data from 19 participants navigating a realistic virtual environment over a 20-minute session, with discomfort rated repeatedly throughout the experiment. Linear mixed-effects models examined gaze constructs spanning fixation stability, visual exploration, and gaze allocation as functions of discomfort, exposure duration, and their interaction. Our results show that fixation stability degraded progressively with increasing discomfort, with the effect strengthening over time. Visual exploration showed no marginal discomfort effect but exhibited significant discomfort-by-time interactions, indicating that saccadic behavior adapts dynamically rather than responding uniformly to discomfort. Gaze allocation was not associated with discomfort but shifted systematically with time. These findings show that cybersickness does not uniformly disrupt gaze. Instead, different aspects of eye-movement behavior respond differently and change in ways that only become visible when discomfort is tracked repeatedly over time. Understanding how gaze evolves during cybersickness progression provides the behavioral grounding needed to better interpret how discomfort shapes the user's visual experience of immersive environments and to design more sensitive detection approaches.

cs.HC↗

Gaze Prediction as Time-Series Forecasting for Virtual Reality Applications: Quantifying Performance Variability and Extreme-Case Errors

Gaze prediction is essential for addressing motion-to-photon latency and ensuring seamless foveated rendering in Virtual Reality. The reliability of gaze forecasting is highly sensitive to individual differences and the eye movements being predicted. We evaluate recurrent, transformer-based, and classification-guided architectures to assess their generalization capabilities across oculomotor events. Using the GazeBase VR and Meta Quest Pro datasets, we analyzed the relationship between the median (P50) and high-percentile (P95) error profiles across subjects. The analysis reveals significant performance variability, showing that subjects with low P50 errors do not always exhibit the lowest extreme-case errors. Consequently, low median errors do not guarantee the robustness of the utilized solution. We discuss inference performance and address the class imbalance problem in short-term gaze prediction. These results identify a gap in standardized evaluation methods, necessitating a shift toward P95-focused, subject-specific metrics to develop reliable and perceptually stable gaze-contingent systems.

cs.HC↗

Privacy Enhancement for Gaze Data Using a Noise-Infused Autoencoder

We present a privacy-enhancing mechanism for gaze signals using a latent-noise autoencoder that prevents users from being re-identified across play sessions without their consent, while retaining the usability of the data for benign tasks. We evaluate privacy-utility trade-offs across biometric identification and gaze prediction tasks, showing that our approach significantly reduces biometric identifiability with minimal utility degradation. Unlike prior methods in this direction, our framework retains physiologically plausible gaze patterns suitable for downstream use, which produces favorable privacy-utility trade-off. This work advances privacy in gaze-based systems by providing a usable and effective mechanism for protecting sensitive gaze data.

cs.CV↗

Exploring the Uncoordinated Privacy Protections of Eye Tracking and VR Motion Data for Unauthorized User Identification

Virtual reality (VR) sensors capture large amounts of user data, including body motion and eye tracking, that contain personally identifying information. While privacy-enhancing techniques can obfuscate this data, incomplete privacy protections risk privacy leakage, which may allow adversaries to leverage unprotected data to identify users without consent. This work examines the extent to which unprotected body motion data can undermine privacy protections for eye tracking data, and vice versa, to enable user identification in VR. These findings highlight a privacy consideration at the intersection of eye tracking and VR, and emphasize the need for privacy protections that address these technologies comprehensively.

cs.HC↗

Gaze Prediction as a Function of Eye Movement Type and Individual Differences

Eye movement prediction is a promising area of research with the potential to improve performance and the user experience of systems based on eye-tracking technology. In this study, we analyze individual differences in gaze prediction performance. We use three fundamentally different models within the analysis: the lightweight Long Short-Term Memory network (LSTM), the transformer-based network for multivariate time series representation learning (TST), and the Oculomotor Plant Mathematical Model wrapped in the Kalman Filter framework (OPKF). Each solution was assessed on different eye-movement types. We show important subject-to-subject variation for all models and eye-movement types. We found that fixation noise is associated with poorer gaze prediction in fixation. For saccades, higher velocities are associated with poorer gaze prediction performance. We think these individual differences are important and propose that future research should report statistics related to inter-subject variation. We also propose that future models should be designed to reduce subject-to-subject variation.

cs.HC↗

Establishing a Baseline for Gaze-driven Authentication Performance in VR: A Breadth-First Investigation on a Very Large Dataset

This paper performs the crucial work of establishing a baseline for gaze-driven authentication performance to begin answering fundamental research questions using a very large dataset of gaze recordings from 9202 people with a level of eye tracking (ET) signal quality equivalent to modern consumer-facing virtual reality (VR) platforms. The size of the employed dataset is at least an order-of-magnitude larger than any other dataset from previous related work. Binocular estimates of the optical and visual axes of the eyes and a minimum duration for enrollment and verification are required for our model to achieve a false rejection rate (FRR) of below 3% at a false acceptance rate (FAR) of 1 in 50,000. In terms of identification accuracy which decreases with gallery size, we estimate that our model would fall below chance-level accuracy for gallery sizes of 148,000 or more. Our major findings indicate that gaze authentication can be as accurate as required by the FIDO standard when driven by a state-of-the-art machine learning architecture and a sufficiently large training dataset.

cs.CV↗

Signal vs Noise in Eye-tracking Data: Biometric Implications and Identity Information Across Frequencies

Prior research states that frequencies below 75 Hz in eye-tracking data represent the primary eye movement termed ``signal'' while those above 75 Hz are deemed ``noise''. This study examines the biometric significance of this signal-noise distinction and its privacy implications. There are important individual differences in a person's eye movement, which lead to reliable biometric performance in the ``signal'' part. Despite minimal eye-movement information in the ``noise'' recordings, there might be significant individual differences. Our results confirm the ``signal'' predominantly contains identity-specific information, yet the ``noise'' also possesses unexpected identity-specific data. This consistency holds for both short-(approx. 20 min) and long-term (approx. 1 year) biometric evaluations. Understanding the location of identity data within the eye movement spectrum is essential for privacy preservation.

cs.HC↗

Evaluation of Eye Tracking Signal Quality for Virtual Reality Applications: A Case Study in the Meta Quest Pro

We present an extensive, in-depth analysis of the eye tracking capabilities of the Meta Quest Pro virtual reality headset using a dataset of eye movement recordings collected from 78 participants. In addition to presenting classical signal quality metrics--spatial accuracy, spatial precision and linearity--in ideal settings, we also study the impact of background luminance and headset slippage on device performance. We additionally present a user-centered analysis of eye tracking signal quality, where we highlight the potential differences in user experience as a function of device performance. This work contributes to a growing understanding of eye tracking signal quality in virtual reality headsets, where the performance of applications such as gaze-based interaction, foveated rendering, and social gaze are directly dependent on the quality of eye tracking signal.

cs.HC↗

Assessing the Privacy Risk of Cross-Platform Identity Linkage using Eye Movement Biometrics

The recent emergence of ubiquitous, multi-platform eye tracking has raised user privacy concerns over re-identification across platforms, where a person is re-identified across multiple eye tracking-enabled platforms using personally identifying information that is implicitly expressed through their eye movement. We present an empirical investigation quantifying a modern eye movement biometric model's ability to link subject identities across three different eye tracking devices using eye movement signals from each device. We show that a state-of-the art eye movement biometrics model demonstrates above-chance levels of biometric performance (34.99% equal error rate, 15% rank-1 identification rate) when linking user identities across one pair of devices, but not for the other. Considering these findings, we also discuss the impact that eye tracking signal quality has on the model's ability to meaningfully associate a subject's identity between two substantially different eye tracking devices. Our investigation advances a fundamental understanding of the privacy risks for identity linkage across platforms by employing both quantitative and qualitative measures of biometric performance, including a visualization of the model's ability to distinguish genuine and imposter authentication attempts across platforms.

cs.HC↗

A Mechanistic Transform Model for Synthesizing Eye Movement Data with Improved Realism

This manuscript demonstrates an improved model-based approach for synthetic degradation of previously captured eye movement signals. Signals recorded on a high-quality eye tracking sensor are transformed such that their resulting eye tracking signal quality is similar to recordings captured on a low-quality target device. The proposed model improves the realism of the degraded signals versus prior approaches by introducing a mechanism for degrading spatial accuracy and temporal precision. Moreover, a percentile-matching technique is demonstrated for mimicking the relative distributional structure of the signal quality characteristics of the target data set. The model is demonstrated to improve realism on a per-feature and per-recording basis using data from an EyeLink 1000 eye tracker and an SMI eye tracker embedded within a virtual reality platform. The model improves the median classification accuracy performance metric by 35.7% versus the benchmark model towards the ideal metric of 50%. This paper also expands the literature by providing an application-agnostic realism assessment workflow for synthetically generated eye movement signals.

cs.HC↗

GazeBase: A Large-Scale, Multi-Stimulus, Longitudinal Eye Movement Dataset

This manuscript presents GazeBase, a large-scale longitudinal dataset containing 12,334 monocular eye-movement recordings captured from 322 college-aged subjects. Subjects completed a battery of seven tasks in two contiguous sessions during each round of recording, including a - 1) fixation task, 2) horizontal saccade task, 3) random oblique saccade task, 4) reading task, 5/6) free viewing of cinematic video task, and 7) gaze-driven gaming task. A total of nine rounds of recording were conducted over a 37 month period, with subjects in each subsequent round recruited exclusively from the prior round. All data was collected using an EyeLink 1000 eye tracker at a 1,000 Hz sampling rate, with a calibration and validation protocol performed before each task to ensure data quality. Due to its large number of subjects and longitudinal nature, GazeBase is well suited for exploring research hypotheses in eye movement biometrics, along with other emerging applications applying machine learning techniques to eye movement signal analysis.

cs.HC↗

Hierarchical HMM for Eye Movement Classification

In this work, we tackle the problem of ternary eye movement classification, which aims to separate fixations, saccades and smooth pursuits from the raw eye positional data. The efficient classification of these different types of eye movements helps to better analyze and utilize the eye tracking data. Different from the existing methods that detect eye movement by several pre-defined threshold values, we propose a hierarchical Hidden Markov Model (HMM) statistical algorithm for detecting fixations, saccades and smooth pursuits. The proposed algorithm leverages different features from the recorded raw eye tracking data with a hierarchical classification strategy, separating one type of eye movement each time. Experimental results demonstrate the effectiveness and robustness of the proposed method by achieving competitive or better performance compared to the state-of-the-art methods.

cs.CV↗

Parallel Oculomotor Plant Mathematical Model for Large Scale Eye Movement Simulation

The usage of eye tracking sensors is expected to grow in virtual (VR) and augmented reality (AR) platforms. Provided that users of these platforms consent to employing captured eye movement signals for authentication and health assessment, it becomes important to estimate oculomotor plant and brain function characteristics in real time. This paper shows a path toward that goal by presenting a parallel processing architecture capable of estimating oculomotor plant characteristics and comparing its performance to a single-threaded implementation. Results show that the parallel implementation improves the speed, accuracy, and throughput of oculomotor plant characteristic estimation versus the original serial version for both large-scale and real-time simulation.

cs.HC↗

Tertiary Eye Movement Classification by a Hybrid Algorithm

The proper classification of major eye movements, saccades, fixations, and smooth pursuits, remains essential to utilizing eye-tracking data. There is difficulty in separating out smooth pursuits from the other behavior types, particularly from fixations. To this end, we propose a new offline algorithm, I-VDT-HMM, for tertiary classification of eye movements. The algorithm combines the simplicity of two foundational algorithms, I-VT and I-DT, as has been implemented in I-VDT, with the statistical predictive power of the Viterbi algorithm. We evaluate the fitness across a dataset of eight eye movement records at eight sampling rates gathered from previous research, with a comparison to the current state-of-the-art using the proposed quantitative and qualitative behavioral scores. The proposed algorithm achieves promising results in clean high sampling frequency data and with slight modifications could show similar results with lower quality data. Though, the statistical aspect of the algorithm comes at a cost of classification time.

cs.CV↗