Searcharxiv⌕ Search

arXiv subjects

Oleksandr Hryhorenko

Publications and source records attributed to Oleksandr Hryhorenko.

3 recordsLinked to original sources

Design optimization, commissioning, and uncertainty analysis of the quadrupole resonator system at Jefferson Lab for SRF material characterization

A quadrupole resonator (QPR) provides a sample-based platform for characterizing materials for superconducting radio-frequency (SRF) applications under controlled field, frequency, and temperature conditions. This paper presents the design optimization, commissioning, and validation of the Jefferson Lab QPR system, including a quantitative assessment of measurement uncertainty. The resonator geometry was re-optimized from the CERN version-II design to improve quadrupole-mode separation and enable four usable modes at 400, 806, 1221, and 1640 MHz. The measurement system combines self-excited-loop RF operation, cable-loss-corrected power calibration, decay-based external-Q calibration, and RF-DC thermal-substitution calorimetry to determine the peak surface magnetic field Bpk and sample surface resistance Rs. Commissioning measurements on bulk Nb and Nb3Sn-Ta-Cu samples validated the system response over a broad range of frequency, temperature, and RF field. The extracted superconducting energy-gap parameters are consistent with the reported values for Nb and Nb3Sn, as well as with those obtained from single-cell cavity measurements. The commissioned system operates from 1.8 K to near the superconducting transition temperature of the sample, with accessible Bpk values from approximately 5 mT to a sample- and temperature-dependent heater-power-budget limit; a maximum field of 60 mT was demonstrated for bulk Nb at 400 MHz and 4 K. The combined relative standard uncertainties are 8.3% for Bpk and below 18% for Rs when r = PDC2/PDC1 is less than 0.9. The worst-case Bpk resolution at the 95% confidence level is approximately 1.35 mT, while the Rs resolution is below 1 nOhm at 10 mT and 2 K. These results establish the JLab QPR as a calibrated, multi-frequency platform with quantified measurement uncertainty for SRF material characterization.

physics.acc-ph↗

Electropolishing-Induced Topographic Defects in Niobium: Insights and Implications for Superconducting Radio Frequency Applications

Electropolishing is the premier surface preparation method for high-Q, high-gradient superconducting RF cavities made of Nb. This leaves behind an apparently smooth surface, yet the achievable peak magnetic fields fall well below the superheating field of Nb, in most cases. In this work, the ultimate surface finish of electropolishing was investigated by studying its effect on highly polished Nb samples. Electropolishing introduces high slope angle sloped-steps at grain boundaries. The magnetic field enhancement and superheating field suppression factors associated with such a geometry are calculated in the London theory. Despite the by-eye smoothness of electropolished Nb, such defects compromise the stability of the low-loss Meissner state, likely limiting the achievable peak accelerating fields in superconducting RF cavities. Finally, the impact of surface roughness on impurity diffusion is investigated which can link surface roughness to the effectiveness of heat treatments like low-temperature baking or nitrogen infusion in the vortex nucleation or hydride hypotheses. Surface roughness tends to decrease the effective dose of impurities as a result of the expansion of impurities into regions with greater internal angle. The effective dose of impurities can be protected by minimizing slope angles and step heights, ensuring uniformity.

cond-mat.supr-con↗

Impact of metallographic polishing on the RF properties of Niobium for SRF applications

The performance of superconducting radio-frequency (SRF) cavities made of Niobium is tied to the quality of their inner surfaces exposed to the radio frequency (RF) waves. Future superconducting particle accelerators, because of their dimensions or the unprecedented stringent technical requirements, require the development of innovative surface processing techniques to improve processing reliability and if possible ecological footprint and cost, compared to conventional chemical processes. Metallographic polishing (MP) has emerged as a promising polishing technology to address these challenges. Previous studies focused on the characterization of the processed material surface at room temperature in the absence of RF waves. However, the evaluation of material properties, such as surface resistance under RF, at cryogenic temperature has failed, primarily due to the unavailability of devices capable of achieving the necessary resolution in the nanohm range. To overcome this limitation, a quadrupole resonator (QPR) has been utilized. The RF results demonstrate that the MP polishing, developed to preserve a high-quality niobium surface with very low surface resistance, is highly effective compared to conventional polishing. This conclusion is further supported by topography and microstructural analysis of the QPR top-hat samples, which revealed the clear superiority of the metallographic approach.

physics.acc-ph↗