Oliver Hupe

Publications and source records attributed to Oliver Hupe.

5 recordsLinked to original sources

Learning-Based Estimation of Spatially Resolved Scatter Radiation Fields in Interventional Radiology

We present three variants of a lightweight, fully connected artificial neural network, suited for interactive estimation of three-dimensional, spatially resolved volumes of scattered radiation fields and a corresponding training pipeline for radiation protection dosimetry in medical radiation fields, such as those found in interventional radiology and cardiology. Accompanying, we present three different synthetically generated datasets with increasing complexity for training, generated using RadField3D, a Monte Carlo simulation application based on Geant4. As the primary scatter object, we employed the torso of a male Alderson RANDO phantom. On those datasets, we evaluate convolutional and fully connected architectures of neural networks to demonstrate which design decisions work well for reconstructing the fluence and spectra distributions over the spatial domain of such radiation fields. All our datasets, as well as our training pipeline, are published as open source in separate repositories. To evaluate the presented neural networks, we define and assess several metrics. Across these measures, the model variants demonstrate good spatial agreement between predicted and ground-truth radiation fields, particularly within specific regions of interest within the radiation field. Of particular relevance for potential application in out-of-field dosimetry is the SMAPE of the scatter radiation field, which represents the most challenging metric and was consistently above 84 %.

cs.LG

Active Eye Lens Dosimetry With Dosepix: Influence of Measurement Position and Lead Glass Shielding

In this work, the effect of the measurement position on measurements of $H_\text{p}(3)$ of a new active eye lens dosemeter prototype based on the Dosepix detector is examined. A comparison between measuring directly in front of the eye and measuring at the side of the head of an Alderson phantom showed no significant influence on the resulting $H_\text{p}(3)$ for different radiation qualities and angles. In addition, to account for the absorption effect of radiation safety glasses, pieces of lead glass were attached to the front and side of the dosemeter. Corresponding effects and consequences for radiation protection measurements have been investigated by using a human like Alderson head phantom as well as thermoluminescent dosemeters (TLDs) and the active eye lens dosemeter prototype. For specific angles, the radiation bypassed the radiation safety glasses and lead glass pieces, leading to an increase in the measured $H_\text{p}(3)$. Compared to TLDs behind radiation safety glasses, measurements with the lead glass shielded prototype resulted in lower values for $H_\text{p}(3)$. Furthermore, the results did not reproduce previous findings where larger dose values were found for Dosepix behind lead glass pieces than for the TLDs behind radiation safety glasses. A possible reason might be that the dimensions of the lead glass pieces are not representative of the radiation safety glasses in front of the eye but, ultimately, it is not yet clear what the main reason for the deviation is. Therefore, it is advisable to test the same methodology in future investigations with other eyewear models and lead glass pieces to investigate whether similar behaviors occur.

physics.med-ph

RadField3D: A Data Generator and Data Format for Deep Learning in Radiation-Protection Dosimetry for Medical Applications

In this research work, we present our open-source Geant4-based Monte-Carlo simulation application, called RadField3D, for generating threedimensional radiation field datasets for dosimetry. Accompanying, we introduce a fast, machine-interpretable data format with a Python API for easy integration into neural network research, that we call RadFiled3D. Both developments are intended to be used to research alternative radiation simulation methods using deep learning.

cs.LG

Active Personal Eye Lens Dosimetry with the Hybrid Pixelated Dosepix Detector

Eye lens dosimetry has been an important field of research in the last decade. Dose measurements with a prototype of an active personal eye lens dosemeter based on the Dosepix detector are presented. The personal dose equivalent at $3\,$mm depth of soft tissue, $H_\text{p}(3)$, was measured in the center front of a water-filled cylinder phantom with a height and diameter of $20\,$cm. The energy dependence of the normalized response is investigated for mean photon energies between $12.4\,$keV and $248\,$keV for continuous reference radiation fields (N-series) according to ISO 4037. The response normalized to N-60 ($\overline{E}=47.9\,\text{keV}$) at $0^\circ$ angle of irradiation stays within the approval limits of IEC 61526 for angles of incidence between $-75^\circ$ and $+75^\circ$. Performance in pulsed photon fields was tested for varying dose rates from $0.1\,\frac{\text{Sv}}{\text{h}}$ up to $1000\,\frac{\text{Sv}}{\text{h}}$ and pulse durations from $1\,\text{ms}$ up to $10\,\text{s}$. The dose measurement works well within the approval limits (acc. to IEC 61526) up to $1\,\frac{\text{Sv}}{\text{h}}$. No significant influence of the pulse duration on the measured dose is found. Reproducibility measurements yield a coefficient of variation which does not exceed $1\,\%$ for two tested eye lens dosemeter prototypes.

physics.med-ph

Personal Dosimetry in Direct Pulsed Photon Fields with the Dosepix Detector

First investigations regarding dosimetric properties of the hybrid, pixelated, photon-counting Dosepix detector in the direct beam of a pulsed photon field (RQR8) for the personal dose equivalent $H\mathrm{_p(10)}$ are presented. The influence quantities such as pulse duration and dose rate were varied, and their responses were compared to the legal limits provided in PTB-A 23.2. The variation of pulse duration at a nearly constant dose rate of about 3.7$\,$Sv/h shows a flat response around 1.0 from 3.6$\,$s down to 2$\,$ms. A response close to 1.0 is achieved for dose rates from 0.07$\,$Sv/h to 35$\,$Sv/h for both pixel sizes. Above this dose rate, the large pixels (220$\,μ$m edge length) are below the lower limit. The small pixels (55$\,μ$m edge length) stay within limits up to 704$\,$Sv/h. The count rate linearity is compared to previous results, confirming the saturating count rate for high dose rates.

physics.med-ph