SearcharxivSearch

arXiv subjects

Olivier Carraz

Publications and source records attributed to Olivier Carraz.

10 recordsLinked to original sources

Impact of rotation on a cold atom interferometer and compensation strategy

Rotations play a detrimental role in achieving ultra-high-performance inertial measurements with an atom interferometer, leading potentially to a total loss of interference contrast and the emergence of dominant phase shift biases. This becomes particularly significant when considering operation in dynamic conditions such as those encountered in Earth orbiting satellites in the perspective of future space gravity missions on-boarding a cold atom accelerometer. We study in this context the impact of rotation on the phase shift and contrast of an atom interferometer and investigate mitigation strategies. An analytical model is derived and compared to experimental demonstrations carried out using an original setup in which the well-controlled proof-mass of a space electrostatic accelerometer is used as the retro-reflection mirror of a cold atom gravimeter. By properly counter-rotating the electrostatic proof-mass, we demonstrate for instance the possibility of recovering the interferometer contrast, otherwise equal to zero, to a level better than 90%, in both cases of constant angular velocities or in presence of angular accelerations. Our results demonstrate the possibility to perform high performance inertial measurements with a cold atom interferometer in a challenging environments.

physics.atom-ph

Towards a realistic noise modelling of quantum sensors for future satellite gravity missions

Mapping the Earth's gravity field from space offers valuable insights into climate change, hydro- and biosphere evolution, and seismic activity. Current satellite gravimetry missions have demonstrated the utility of gravity data in understanding global mass transport phenomena, climate dynamics, and geological processes. However, state-of-the-art measurement techniques face noise and long-term drift limitations, which propagate into the recovery of Earth's time-varying gravity field. Quantum sensors, particularly Cold Atom Interferometry (CAI), offer promise for improving the accuracy and stability of space-based gravity measurements. Therefore, CAI has emerged as a promising measurement technique for future gravimetric satellite missions due to their potential for measuring gravitational forces and gradients with high precision and accuracy, particularly at low frequencies (sub-mHz). This study explores the sensitivity of CAI accelerometers and gradiometers to the errors in measuring the satellite's attitude. We explore the low-low satellite-to-satellite and gravity gradiometry concepts and build the respective analytical models of measurements and associated errors. We selected an ambitious scenario for CAI parameters that illustrates a potential path for increasing instrument accuracies and capabilities for space gravimetry. Two operational modes, concurrent (where a new cloud is generated while another is moved to the interferometric chamber) and sequential (where cloud generation and interferometry happen in the same place), are compared to mitigate the effects of inaccurately known attitude rates on Coriolis accelerations. The sequential mode shows the potential to reduce these effects since the atom cloud has an initial zero velocity. [...]

physics.ins-det

Hybrid electrostatic-atomic accelerometer for future space gravity missions

Long term observation of temporal Earth's gravity field with enhanced temporal and spatial resolution is a major objective for future satellite gravity missions. Improving the performance of the accelerometers present in such missions is one of the main path to explore. In this context, we propose to study an original concept of a hybrid accelerometer associating a state-of-the-art electrostatic accelerometer (EA) and a promising quantum sensor based on cold atom interferometry. To assess the performance potential of such instrument, numerical simulations have been performed to determine its impact in term of gravity field retrieval. Taking advantage of the long term stability of the cold atom interferometer (CAI), it has been shown that the reduced drift of the hybrid sensor could lead to improved gravity field retrieval. Nevertheless this gain vanishes once temporal variations of the gravity field and related aliasing effects are taken into account. Improved de-aliasing models or some specific satellite constellations are then required to maximize the impact of the accelerometer performance gain. To evaluate the achievable acceleration performance in orbit, a numerical simulator of the hybrid accelerometer has been developed and preliminary results are given. The instrument simulator has been in part validated by reproducing the performance achieved with a hybrid lab prototype operating on ground. The problematic of satellite rotation impact on the CAI has been also investigated both with instrument performance simulations and experimental demonstrations. It has been shown that the proposed configuration, where the EA's proof-mass acts as the reference mirror for the CAI, seems a promising approach to allow the mitigation of satellite rotation. A preliminary design has been elaborated along with a preliminary error, mass, volume and electrical power consumption budget.

physics.atom-ph

Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map

We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with ESA and national space and research funding agencies.

astro-ph.IM

Measuring the Earth's gravity field with cold atom interferometers

The scope of the paper is to propose different concepts for future space gravity missions using Cold Atom Interferometers (CAI) for measuring the diagonal elements of the gravity gradient tensor, the spacecraft angular velocity and the spacecraft acceleration. The aim is to achieve better performance than previous space gravity missions due to a very low white noise spectral behaviour of the CAI instrument and a very high common mode rejection, with the ultimate goals of determining the fine structures of the gravity field with higher accuracy than GOCE and detecting time-variable signals in the gravity field.

physics.atom-ph

Narrow linewidth single laser source system for onboard atom interferometry

A compact and robust laser system for atom interferometry based on a frequency-doubled telecom laser is presented. Thanks to an original stabilization architecture on a saturated absorption setup, we obtain a frequency-agile laser system allowing fast tuning of the laser frequency over 1 GHz in few ms using a single laser source. The different laser frequencies used for atom interferometry are generated by changing dynamically the frequency of the laser and by creating sidebands using a phase modulator. A laser system for Rubidium 87 atom interferometry using only one laser source based on a frequency doubled telecom fiber bench is then built. We take advantage of the maturity of fiber telecom technology to reduce the number of free-space optical components (which are intrinsically less stable) and to make the setup compact and much less sensitive to vibrations and thermal fluctuations. This source provides spectral linewidth below 2.5 kHz, which is required for precision atom interferometry, and particularly for a high performance atomic inertial sensor.

physics.atom-ph

A spaceborne gravity gradiometer concept based on cold atom interferometers for measuring Earth's gravity field

We propose a concept for future space gravity missions using cold atom interferometers for measuring the diagonal elements of the gravity gradient tensor and the spacecraft angular velocity. The aim is to achieve better performance than previous space gravity missions due to a very low white noise spectral behavior and a very high common mode rejection, with the ultimate goals of determining the fine structures of the gravity field with higher accuracy than GOCE and detecting time-variable signals in the gravity field better than GRACE.

physics.atom-ph

Compact cold atom gravimeter for field applications

We present a cold atom gravimeter dedicated to field applications. Despite the compactness of our gravimeter, we obtain performances (sensitivity 42 microGal/Hz^0.5, accuracy 25 microGal) close to the bestgravimeters. We report gravity measurements in an elevator which led us to the determination of the Earth's gravity gradient with a precision of 4 E. These measurements in a non-laboratory environment demonstrate that our technology of gravimeter is enough compact, reliable and robust for field applications. Finally, we report gravity measurements in a moving elevator which open the way to absolute gravity measurements in an aircraft or a boat.

physics.ins-det

Phase shift in an atom interferometer induced by the additional laser lines of a Raman laser generated by modulation

The use of Raman laser generated by modulation for light-pulse atom interferometer allows to have a laser system more compact and robust. However, the additional laser frequencies generated can perturb the atom interferometer. In this article, we present a precise calculation of the phase shift induced by the additional laser frequencies. The model is validated by comparison with experimental measurements on an atom gravimeter. The uncertainty of the phase shift determination limits the accuracy of our compact gravimeter at 8.10^-8 m/s^2. We show that it is possible to reduce considerably this inaccuracy with a better control of experimental parameters or with particular interferometer configurations.

physics.atom-ph

I.C.E.: An Ultra-Cold Atom Source for Long-Baseline Interferometric Inertial Sensors in Reduced Gravity

The accuracy and precision of current atom-interferometric inertialsensors rival state-of-the-art conventional devices using artifact-based test masses . Atomic sensors are well suited for fundamental measurements of gravito-inertial fields. The sensitivity required to test gravitational theories can be achieved by extending the baseline of the interferometer. The I.C.E. (Interférométrie Cohérente pour l'Espace) interferometer aims to achieve long interrogation times in compact apparatus via reduced gravity. We have tested a cold-atom source during airplane parabolic flights. We show that this environment is compatible with free-fall interferometric measurements using up to 4 second interrogation time. We present the next-generation apparatus using degenerate gases for low release-velocity atomic sources in space-borne experiments.

physics.atom-ph