Searcharxiv⌕ Search

arXiv subjects

Olivier Guillaudin

Publications and source records attributed to Olivier Guillaudin.

4 recordsLinked to original sources

First Directional Dark Matter Limits from the MIMAC μ-TPC Detector

We present a directional dark matter search using the MIMAC (Micro-tpc Matrix of Chambers) detector at the Modane Underground Laboratory. Operating a low-pressure gas mixture of i-C4H10 and 50% CHF3 at 30 mbar, without any shielding, the detector allows the reconstruction of the 3D tracks of nuclear recoils produced in the 6-liter active volume. Directionality is a crucial tool to discriminate true WIMP signals from those of background producing identical recoils, such as neutrons. We analyze data from two independent chambers with effective exposures of 495.1 and 354.2 days, respectively. To estimate the background directly from the data, we apply a standard ON/OFF spatial analysis. By projecting the reconstructed tracks onto the galactic map and applying a moving kinematic energy cut depending on the WIMP mass, we compare the event rate in the signal direction with multiple OFF-source regions. Finding no significant excess of events in the direction of the Cygnus constellation, we set an upper limit on the spin-dependent WIMP-protoncross section.

astro-ph.CO↗

3D-Deuteron Track Recoils Produced by Neutron Capture in Hydrogen Measured by MIMAC-35 cm

The neutron capture is a process that concerns most of the nuclei used to build our detectors. This process produces protons, alpha particles, and gamma rays which generate background signals. Characterizing this background is important for rare event searches, such as dark matter detection or Coherent Elastic Neutrino-Nucleus Scattering (CEvNS). This paper presents the result of the direct measurement of thermal neutron captures in hydrogen using a new MIcro-TPC MAtrix Chamber (MIMAC-35 cm) detector with a sensitive volume of 35 x 35 x 29 cm3. Data were collected over more than 5 days (443519 sec) with a gas mixture at 30 mbar of 70% isobutane (C4H10) and 30% trifluoromethane (CHF3). Our discrimination method is based on using 3D tracks and released ionization energy, in order to discriminate nuclear recoils (NR) from the dominant electron recoil (ER) background. This method enables the clear identification of 1.3 keV deuteron tracks resulting of nuclear capture reaction 1H(n, γ)2H. We observed 51 neutron capture events among more than 11 million total events mainly produced by muons in the experimental room of our ground laboratory. In parallel we have measured the thermal neutron flux just below the chamber with a BF3 detector and a simulation has been performed to estimate the number of captures expected. This work shows the discrimination power of MIMAC search for low-energy (E < 1 keV) rare event with a huge background without any shielding.

physics.ins-det↗

Directionality and head-tail recognition in the keV-range with the MIMAC detector by deconvolution of the ionic signal

Directional detection is the only strategy for the unambiguous identification of galactic Dark Matter (DM) even in the presence of an irreducible background such as beyond the neutrino floor. This approach requires measuring the direction of a DM-induced nuclear recoil in the keV-range. To probe such low energies, directional detectors must operate at high gain where 3D track reconstruction can be distorted by the influence of the numerous ions produced in the avalanches. The article describes the interplay between electrons and ions during signal formation in a Micromegas. It introduces SimuMimac, a simulation tool dedicated to high gain detection that agrees with MIMAC measurements. This work proposes an analytical formula to deconvolve the ionic signal induced on the grid from any measurements, with no need for prior nor ad hoc parameter. This deconvolution is experimentally tested and validated, revealing the fine structure of the primary electrons cloud and consequently leading to head-tail recognition in the keV-range. Finally, the article presents how this deconvolution can be used for directionality by reconstructing the spectra of mono-energetic $27~\mathrm{keV}$ and $8~\mathrm{keV}$ neutrons with an angular resolution better than $15^\circ$. This novel approach for directionality appears as complementary to the standard one from 3D tracks reconstruction and offers redundancy for improving directional performances at high gain in the keV region.

physics.ins-det↗

Fast neutron spectroscopy from 1 MeV up to 15 MeV with Mimac-FastN, a mobile and directional fast neutron spectrometer

In the frame of direct dark matter search, the fast neutrons producing elastic collisions are the ultimate background. The MIMAC (MIcro-tpc MAtrix Chambers) project has developed a directional detector providing the directional signature to discriminate them based on 3D nuclear tracks reconstruction. The MIMAC team of the LPSC has adapted one MIMAC chamber as a portable fast neutron spectrometer, the Mimac-FastN detector, having a very large neutron energy range (10 keV - 600 MeV) with different gas mixtures and pressures. The present paper shows its main features and functionality and demonstrates its potential in the energy range from 1 MeV to 15 MeV at the GENESIS neutron source facility of LPSC.

physics.ins-det↗