Diffuse Maxwellian illumination for safe wide-field retinal Doppler holography

We report a diffuse Maxwellian illumination scheme for wide-field retinal laser Doppler holography. Inserting an engineered diffuser in the illumination arm transforms a spatially concentrated near-infrared laser focus into an angularly diversified illumination pattern, thereby reducing local irradiance near the anterior segment while preserving coherent interferometric detection. This configuration allows the eyepiece to be positioned closer to the cornea, increasing the digitally reconstructed retinal field of view without producing a localized corneal hot spot. We compare three illumination geometries: focused non-diffuse illumination, diffuse illumination at the same cornea--eyepiece distance, and diffuse Maxwellian illumination. Diffuse Maxwellian illumination expands the retinal field of view while preserving Doppler contrast in broad and high-frequency fluctuation bands. Light-hazard assessment is limited to the current ophthalmic standards ISO 15004-2:2024 and ANSI Z80.36-2021. Based on measured beam profiles, the recommended operating power at 852 nm is set by the most restrictive relevant exposure condition among the assessed anterior-segment, iris, and retinal limits. These results support diffuse illumination as a practical route toward safer, non-mydriatic, wide-field Doppler holography of the human retina.

physics.optics

Retinal arterial blood flow measured by real-time Doppler holography at 33,000 frames per second

This study presents a novel quantitative estimation method for total retinal arterial blood flow utilizing real-time Doppler holography at an unprecedented frame rate of 33,000 frames per second. This technique, leveraging high-speed digital holography, enables non-invasive angiographic imaging of the retina, providing detailed blood flow contrasts essential for assessing retinal health. The proposed quantitative analysis method consists of segmenting primary in-plane retinal arteries and calculating local blood velocity using Doppler frequency broadening. The analysis integrates a forward scattering model to achieve blood flow estimation. Our findings highlight the potential of Doppler holography as a powerful tool for diagnosing and monitoring the treatment of retinal vascular conditions, complementary to existing imaging methods.

eess.IV