Searcharxiv⌕ Search

arXiv subjects

Olivier Thouvenin

Publications and source records attributed to Olivier Thouvenin.

8 recordsLinked to original sources

Rolling phase modulation regime for dynamic full field OCT

Dynamic full-field optical coherence tomography (DFFOCT) has recently emerged as an invaluable label-free microscopy technique, owing to its sensitivity to cell activity, as well as speed and sectioning ability. However, the quality of DFFOCT images are often degraded due to phase noise and fringe artifacts. In this work, we present a new implementation named Rolling-Phase (RP) DFFOCT, in which the reference arm is slowly scanned over magnitudes exceeding 2$π$. We demonstrate mathematically and experimentally that it shows superior image quality while enabling to extract both static and dynamic contrast simultaneously. We showcase RP DFFOCT on monkey retinal explant, and demonstrate its ability to better resolve subcellular structures, including intranuclear activity.

q-bio.QM↗

Comparative analysis of full-field OCT and optical transmission tomography

This work compares two tomographic imaging technologies, time-domain full-field optical coherence tomography (FFOCT) working in reflection and optical transmission tomography (OTT), using a new optical setup that combines both. We show that, due to forward-scattering properties, the axial sectioning and contrast in OTT can be optimized by tuning illumination. The influence of sample scattering and thickness are discussed. We illustrate the comparison of the two methods in static (morphology) and dynamic (metabolic contrast) regimes using cell cultures, tissues and entire organisms emphasizing the advantages of both approaches.

physics.optics↗

Interface Self-Referenced Dynamic Full-Field Optical Coherence Tomography

Dynamic full-field optical coherence tomography (D-FFOCT) has recently emerged as an invaluable live label-free and non-invasive imaging modality able to image subcellular biological structures and their metabolic activity within complex 3D samples. However, D-FFOCT suffers from fringe artefacts when imaging nearby reflective surfaces and is highly sensitive to vibrations. Here, we present interface Self-Referenced (iSR) D-FFOCT, an alternative configuration to D-FFOCT that takes advantage of the presence of the sample coverslip in between the sample and the objective by using it as a defocused reference arm, thus avoiding the aforementioned artefacts. We demonstrate the ability of iSR D-FFOCT to image 2D fibroblast cell cultures, which are among the flattest mammalian cells.

physics.optics↗

Dynamic Full-Field Optical Coherence Tomography module adapted to commercial microscopes for longitudinal in vitro cell culture study

Dynamic full-field optical coherence tomography (D-FFOCT) has recently emerged as a label-free imaging tool, capable of resolving cell types and organelles within 3D live samples, whilst monitoring their activity at tens of milliseconds resolution. Here, a D-FFOCT module design is presented which can be coupled to a commercial microscope with a stage top incubator, allowing non-invasive label-free longitudinal imaging over periods of minutes to weeks on the same sample. Long term volumetric imaging on human induced pluripotent stem cell-derived retinal organoids is demonstrated, highlighting tissue and cell organisation as well as cell shape, motility and division. Imaging on retinal explants highlights single 3D cone and rod structures. An optimal workflow for data acquisition, postprocessing and saving is demonstrated, resulting in a time gain factor of 10 compared to prior state of the art. Finally, a method to increase D-FFOCT signal-to-noise ratio is demonstrated, allowing rapid organoid screening.

q-bio.QM↗

Label free optical transmission tomography for biosystems: Intracellular structures and dynamics

There is an increasing need for label free methods that could reveal intracellular structures and dynamics. In this context, we develop a new optical tomography method working in transmission - Full-field optical transmission tomography (FF-OTT). The method can measure the forward scattering signals and reveal the metabolic time-dependent signals in living cells. FF-OTT is a common path interferometer taking advantage of the Gouy phase shift - a π phase shift that the light wave experiences around the focus. By modulating position of the focus one can alter the phase of the scattered light. Demodulation of images with different phases rejects the background and enhances the light from the depth-of-focus, thus producing an optical section. We test FF-OTT by imaging single-cell diatoms and ex vivo biological samples. In fresh samples, we show that the intracellular motions create visible intensity fluctuations in FF-OTT so that the method is able to reveal a metabolic dynamic contrast. FF-OTT was found to be an efficient label free technique that can be readily implemented thanks to a robust common-path speckle-free interferometer design using an incoherent light source.

physics.optics↗

Partial-Field Illumination Ophthalmoscope: improving the contrast of a camera-based retinal imager

Effective and accurate in-vivo diagnosis of retinal pathologies requires high performance imaging devices, combining a large field of view and the ability to discriminate the ballistic signal from the diffuse background in order to provide a highly contrasted image of the retinal structures. Here, we have implemented the Partial-Field Illumination Ophthalmoscope, a patterned illumination modality, integrated on a high pixel rate adaptive optics full-field microscope. This non-invasive technique enables us to mitigate the low signal-to-noise ratio, intrinsic of full-field ophthalmoscopes, by partially illuminating the retina with complementary patterns to reconstruct a wide field image. This new modality provides an image contrast spanning from the full-field to the confocal contrast, depending on the pattern size. As a result, it offers various trade-offs in terms of contrast and acquisition speed, guiding the users towards the most efficient system for a particular clinical application.

physics.med-ph↗

Curved-Full-Field OCT for high-resolution imaging of living human retina over a large field-of-view

Allying high-resolution with a large field-of-view (FOV) is of great importance in the fields of biology and medicine, but particularly challenging when imaging non-flat living samples such as the human retina. Indeed, high-resolution is normally achieved with adaptive optics (AO) and scanning methods, which considerably reduce the useful FOV and increase the system complexity. An alternative technique is time-domain Full-Field Optical Coherence Tomography (FF-OCT), which has already shown its potential for in-vivo high-resolution retinal imaging. Here, we introduce curved-field FF-OCT, capable of matching the coherence gate geometry to the sample curvature, thus achieving a larger FOV than previously possible. Using this instrument, we obtained high-resolution images of living human photoreceptors close to the foveal center without AO and with a 1 mm x 1 mm FOV in a single shot. This novel advance enables the extraction of photoreceptor-based biomarkers with ease and spatiotemporal monitoring of individual photoreceptors. We compare our findings with AO-assisted ophthalmoscopes, highlighting the potential of FF-OCT, as a relatively simple, compact and low-cost system, to become a routine clinical imaging technique.

physics.med-ph↗

Dynamic full field optical coherence tomography: subcellular metabolic contrast revealed in tissues by temporal analysis of interferometric signals

We developed a new endogenous approach to reveal subcellular metabolic contrast in fresh ex vivo tissues taking advantage of the time dependence of the full field optical coherence tomography interferometric signals. This method reveals signals linked with local activity of the endogenous scattering elements which can reveal cells where other imaging techniques fail or need exogenous contrast agents. We benefit from the micrometric transverse resolution of full field OCT to image intracellular features. We used this time dependence to identify different dynamics at the millisecond scale on a wide range of organs in normal or pathological conditions.

physics.med-ph↗