SearcharxivSearch

arXiv subjects

Orlando P. Simonetti

Publications and source records attributed to Orlando P. Simonetti.

7 recordsLinked to original sources

Improved Robustness for Deep Learning-based Segmentation of Multi-Center Myocardial Perfusion MRI Datasets Using Data Adaptive Uncertainty-guided Space-time Analysis

Background. Fully automatic analysis of myocardial perfusion MRI datasets enables rapid and objective reporting of stress/rest studies in patients with suspected ischemic heart disease. Developing deep learning techniques that can analyze multi-center datasets despite limited training data and variations in software and hardware is an ongoing challenge. Methods. Datasets from 3 medical centers acquired at 3T (n = 150 subjects) were included: an internal dataset (inD; n = 95) and two external datasets (exDs; n = 55) used for evaluating the robustness of the trained deep neural network (DNN) models against differences in pulse sequence (exD-1) and scanner vendor (exD-2). A subset of inD (n = 85) was used for training/validation of a pool of DNNs for segmentation, all using the same spatiotemporal U-Net architecture and hyperparameters but with different parameter initializations. We employed a space-time sliding-patch analysis approach that automatically yields a pixel-wise "uncertainty map" as a byproduct of the segmentation process. In our approach, a given test case is segmented by all members of the DNN pool and the resulting uncertainty maps are leveraged to automatically select the "best" one among the pool of solutions. Results. The proposed DAUGS analysis approach performed similarly to the established approach on the internal dataset (p = n.s.) whereas it significantly outperformed on the external datasets (p < 0.005 for exD-1 and exD-2). Moreover, the number of image series with "failed" segmentation was significantly lower for the proposed vs. the established approach (4.3% vs. 17.1%, p < 0.0005). Conclusions. The proposed DAUGS analysis approach has the potential to improve the robustness of deep learning methods for segmentation of multi-center stress perfusion datasets with variations in the choice of pulse sequence, site location or scanner vendor.

eess.IV

Motion-robust free-running volumetric cardiovascular MRI

PURPOSE: To present and assess an outlier mitigation method that makes free-running volumetric cardiovascular MRI (CMR) more robust to motion. METHODS: The proposed method, called compressive recovery with outlier rejection (CORe), models outliers in the measured data as an additive auxiliary variable. We enforce MR physics-guided group sparsity on the auxiliary variable, and jointly estimate it along with the image using an iterative algorithm. For evaluation, CORe is first compared to traditional compressed sensing (CS), robust regression (RR), and an existing outlier rejection method using two simulation studies. Then, CORe is compared to CS using seven three-dimensional (3D) cine, 12 rest four-dimensional (4D) flow, and eight stress 4D flow imaging datasets. RESULTS: Our simulation studies show that CORe outperforms CS, RR, and the existing outlier rejection method in terms of normalized mean square error and structural similarity index across 55 different realizations. The expert reader evaluation of 3D cine images demonstrates that CORe is more effective in suppressing artifacts while maintaining or improving image sharpness. Finally, 4D flow images show that CORe yields more reliable and consistent flow measurements, especially in the presence of involuntary subject motion or exercise stress. CONCLUSION: An outlier rejection method is presented and tested using simulated and measured data. This method can help suppress motion artifacts in a wide range of free-running CMR applications. CODE & DATA: Implementation code and datasets are available on GitHub at http://github.com/OSU-MR/motion-robust-CMR

eess.IV

Cardiac and respiratory motion extraction for MRI using Pilot Tone-a patient study

Background: Several studies have shown that both respiratory and cardiac motion can be extracted from the Pilot Tone (PT) signal successfully. However, most of these studies were performed in healthy volunteers. In addition, validating PT using ECG as a reference can be problematic because both PT and ECG tend to be unreliable in patients with arrhythmias. Purpose: We seek to evaluate the accuracy and reliability of the cardiac and respiratory signals extracted from PT in patients clinically referred for cardiovascular MRI with the image-derived signals as the reference. Methods: Twenty-three patients were scanned on a 1.5 T scanner using balanced steady-state free-precession real-time (RT) cine sequence. The PT signal was generated by a built-in PT transmitter integrated within the body array coil. For comparison, commercial ECG and BioMatrix (BM) respiratory sensor signals were synchronously recorded. Results: The respiratory motion extracted from PT correlated positively with the image-derived respiratory signal in all cases and showed a stronger correlation (absolute coefficient: 0.95+-0.09) than BM (0.72+-0.24). For the cardiac signal, PT trigger jitter (standard deviation of PT trigger locations relative to ECG triggers) ranged from 6.6 to 83.3 ms, with a median of 21.8 ms. The mean absolute difference between the PT and corresponding ECG cardiac cycle duration was less than 5% of the averaged ECG RR interval for 21 out of 23 patients. Overall, the performance of PT-based trigger extraction was comparable to that of ECG. We did not observe significant linear dependence (p>0.28) of PT delay and PT jitter on the patients' BMI or cardiac cycle duration. Conclusions: This study demonstrates the potential of PT to monitor both respiratory and cardiac motion in patients clinically referred for cardiovascular MRI.

eess.SP

Automatic image-based respiratory signal extraction in real-time CMR

Purpose: To develop a fully automatic method for extraction and directionality determination of respiratory signal in free-breathing, real-time (RT) cardiac MRI. Methods: The respiratory signal is extracted by a principal component analysis method from RT cine images. Then, a two-step procedure is used to determine the directionality (sign) of the respiratory signal. First, the signal polarity of all slices is made consistent with a reference slice. Second, a global sign correction is performed by maximizing the correlation of the respiratory signal with the zeroth-moment center curve. The proposed method is evaluated in multi-slice RT cine from eleven volunteers and two patients. The motion in a manually selected region-of-interest is used as reference. Results: The extracted respiratory signal using the proposed method exhibits high, positive correlation with the reference in all cases and is more robust compared to a recently proposed method. To demonstrate its clinical utility, the method is used to identify heartbeats from inspiratory and expiratory phases and, in turn, to account for respiration-induced changes in the cardiac output. Conclusions: The proposed method enables fully automatic extraction and directionality determinations of respiratory signal from RT cardiac cine images, allowing accurate cardiac function quantification.

eess.IV

Automatic Extraction and Sign Determination of Respiratory Signal in Real-time Cardiac Magnetic Resonance imaging

In real-time (RT) cardiac cine imaging, a stack of 2D slices is collected sequentially under free-breathing conditions. A complete heartbeat from each slice is then used for cardiac function quantification. The inter-slice respiratory mismatch can compromise accurate quantification of cardiac function. Methods based on principal components analysis (PCA) have been proposed to extract the respiratory signal from RT cardiac cine, but these methods cannot resolve the inter-slice sign ambiguity of the respiratory signal. In this work, we propose a fully automatic sign correction procedure based on the similarity of neighboring slices and correlation to the center-of-mass curve. The proposed method is evaluated in eleven volunteers, with ten slices per volunteer. The motion in a manually selected region-of-interest (ROI) is used as a reference. The results show that the extracted respiratory signal has a high, positive correlation with the reference in all cases. The qualitative assessment of images also shows that the proposed approach can accurately identify heartbeats, one from each slice, belonging to the same respiratory phase. This approach can improve cardiac function quantification for RT cine without manual intervention.

eess.IV

Identifying Relevant Eigenimages - a Random Matrix Approach

Dimensional reduction of high dimensional data can be achieved by keeping only the relevant eigenmodes after principal component analysis. However, differentiating relevant eigenmodes from the random noise eigenmodes is problematic. A new method based on the random matrix theory and a statistical goodness-of-fit test is proposed in this paper. It is validated by numerical simulations and applied to real-time magnetic resonance cardiac cine images.

physics.data-an