SearcharxivSearch

arXiv subjects

Osamu Sasaki

Publications and source records attributed to Osamu Sasaki.

6 recordsLinked to original sources

Hit-rate capability of a silicon strip detector module for decay positron detection in the J-PARC muon $g-2$/EDM experiment

In the J-PARC muon $g-2$/EDM experiment, a silicon strip detector will be used to detect positrons from muon decays. The detector consists of planes of detector modules arranged radially. The expected maximum hit rate reaches 1.4~MHz per sensor strip, and achieving high detection efficiency even under such hit-rate conditions is a key performance requirement. We have developed the smallest unit of the detector module, and its performance was evaluated using a muon beam at the J-PARC MLF H-line. The specifications of the detector module and the evaluated hit-rate capability are described in this article.

physics.ins-det

Irradiation Studies of TGC Electronics Components for the ATLAS Experiment at High-Luminosity LHC

This paper evaluates the radiation tolerance of commercial off-the-shelf (COTS) electronics components for use in the Thin Gap Chamber (TGC) frontend electronics of the ATLAS experiment at the High-Luminosity LHC (HL-LHC). The ATLAS experiment has accumulated more than 450 fb^-1 of data as of 2025. Its luminosity upgrade, the HL-LHC scheduled to begin operation in 2030, will deliver 3000-4000 fb^-1 over ten years and lead to substantially higher radiation levels in detector electronics. The radiation levels for the TGC frontend electronics are estimated to be 4.1-7.3 Gy in terms of Total Ionizing Dose (TID) and 1.1-2.2 x 10^11 n_1MeV cm^-2 in terms of Non-Ionizing Energy Loss (NIEL). To evaluate component suitability under these conditions, TID tests were conducted using Cobalt-60 gamma rays at Nagoya University, and NIEL tests were performed with the Tandem Accelerator at Kobe University. Various COTS components, including SFP+ optical transceivers, clock jitter cleaners, optical fibers, voltage references, operational amplifiers, analog-to-digital converters, digital-to-analog converters, SD cards, flash memories, and low-dropout regulators, were tested and evaluated against the required radiation levels. The results demonstrate that all evaluated components meet the TID and NIEL tolerance requirements for application in the TGC frontend electronics at the HL-LHC.

physics.ins-det

Velocity dependence of the mass modifications of $ρ$ and $ω$ mesons in 12 GeV $p+A$ reactions

This study measured the invariant mass spectra of $ρ$ and $ω$ mesons in the $e^+e^-$ decay channel for 12 GeV (12.9 GeV/$c$) $p+\mathrm{C}$ and $p+\mathrm{Cu}$ reactions ($\sqrt{s}_{NN}=5.1$ GeV) at the KEK 12-GeV Proton Synchrotron. The measured spectra were divided into three $βγ$ regions to examine their velocity dependence. Across all regions, significant excesses were observed on the low-mass side of the $ω$ meson peak, beyond the contributions of known hadronic sources, in the data of the C and Cu targets. Model calculations were subsequently performed to evaluate the magnitudes of the mass modifications of $ρ$ and $ω$ mesons.

nucl-ex

Analysis of spectral modification of $ϕ$ mesons at finite density using a transport approach in the 12 GeV pA reactions

The hadron spectrum at finite density is an important observable for exploring the origin of hadron masses. In the KEK-PS E325 experiment, the di-electron decays of phi mesons inside and outside nuclei were measured using 12 GeV pA reactions. In the previous analysis, a significant excess was observed on the low-mass side of the phi meson peak in the data for slow-moving phi mesons ($βγ=p_ϕ/m_ϕ<1.25$) with the Cu target, and in-medium vector meson spectral modification was verified. We newly employed the PHSD transport approach to take into account the time evolution of spatial density distribution of the target nuclei. Consistent with the previous analysis, a significant excess was observed in the present analysis as well. It was found that incorporating momentum dependence into the spectral modification leads to better agreement with the experimental results. For the slow-moving $ϕ$ mesons with the Cu target, the newly obtained modification parameters are consistent with those from the previous analysis within the uncertainties.

nucl-ex

Subnanosecond Time-to-Digital Converter Implemented in a Kintex-7 FPGA

Time-to-digital converters (TDCs) are used in various fields, including high-energy physics. One advantage of implementing TDCs in field-programmable gate arrays (FPGAs) is the flexibility on the modification of the logics, which is useful to cope with the changes in the experimental conditions. Recent FPGAs make it possible to implement TDCs with a time resolution less than 10 ps. On the other hand, various drift chambers require a time resolution of O(0.1) ns, and a simple and easy-to-implement TDC is useful for a robust operation. Herein an eight-channel TDC with a variable bin size down to 0.28 ns is implemented in a Xilinx Kintex-7 FPGA and tested. The TDC is based on a multisampling scheme with quad phase clocks synchronised with an external reference clock. Calibration of the bin size is unnecessary if a stable reference clock is available, which is common in high-energy physics experiments. Depending on the channel, the standard deviation of the differential nonlinearity for a 0.28 ns bin size is 0.13-0.31. The performance has a negligible dependence on the temperature. The power consumption and the potential to extend the number of channels are also discussed.

physics.ins-det

Position resolution and efficiency measurements with large scale Thin Gap Chambers for the super LHC

New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6 Coulomb/cm of wire, without showing any deterioration in their performance. Two large (1.2 x 0.8 m^2) prototypes containing four gaps, each gap providing pad, strips and wires readout, with a total thickness of 50 mm, have been constructed. Their local spatial resolution has been measured in a 100 GeV/c muon test beam at CERN. At perpendicular incidence angle, single gap position resolution better than 60 microns has been obtained. For incidence angle of 20 degrees resolution of less than 100 micron was achieved. TGC prototypes were also tested under a flux of 10^5 Hz/cm^2 of 5.5-6.5 MeV neutrons, showing a high efficiency for cosmic muons detection.

physics.ins-det