SearcharxivSearch

arXiv subjects

Oscar Bates

Publications and source records attributed to Oscar Bates.

7 recordsLinked to original sources

Compute-Optimal Network Design for Echocardiography Myocardial Segmentation and Perfusion Quantification using Neural Scaling Laws

Myocardial perfusion quantification using contrast-enhanced ultrasound offers a bedside non-ionizing alternative to nuclear imaging modalities. However, its clinical adoption is hindered by time-consuming manual labelling. Automated segmentation has proved challenging due to a paucity of in-domain training data. Adapting strategies currently used to optimise large language models for large datasets, we apply neural scaling laws to predict network performance for myocardial segmentation. We extrapolate performance on subsets of the data to determine optimal network size on the CAMUS echocardiography dataset and a 25-patient contrast-enhanced ultrasound (CEUS) dataset. Finally, we validate the clinical utility of our models by comparing the final myocardial perfusion parameters with those obtained by a senior cardiologist. Extrapolation based on the scaling law is predictive of test loss at the full dataset size, allowing us to select two networks that obtained state-of-the-art performance on CAMUS with a 240-fold reduction in parameter count. We observe the gradient of the scaling law transfers from CAMUS to the CEUS dataset with a bias in the predicted losses. The automatically segmented masks perform equivalently to a senior cardiologist in myocardial perfusion quantification. These results establish neural scaling laws as a practical tool for data-driven compute-optimal model design for small imaging datasets.

eess.IV

Reconstructing 3D Neural Hemodynamics using Sparse Ultrasound Localization Microscopy Data

Ultrasound Localization Microscopy (ULM) has presented great potential in functional imaging, benefiting from its ability to reconstruct deep microvasculature. However, the hemodynamic reconstruction is compromised by sparsity in the ULM data, as a limited number of MB tracks cannot sample the complete speed profile in one vessel. Here, we propose to reconstruct hemodynamics using sparse ULM velocity maps by solving a laminar flow model through stochastic variational inference. In addition to vascular geometry and flow velocity maps, the proposed method generates two new ULM maps - a pressure gradient map and a map describing uncertainty of the estimation. By investigating the effect of sparsity in ULM maps on the quantification and visualization of hemodynamics, we demonstrate the effectiveness of the proposed method in dealing with sparse ULM maps via simulations and 3D rat brain imaging. Accurately reconstructing a broad range of hemodynamic parameters and associate uncertanties using sparse ULM data may help detect subtle and dynamic brain activity.

eess.IV

Automatic skull-template alignment without a guidance image

Transcranial ultrasound must overcome the significant challenge of the human skull, limiting both imaging and therapeutic applications. While high-fidelity numerical simulations can compensate for skull-induced distortions, they require precise skull templates (typically derived from Computed Tomography, CT) and spatial alignment to the patient's anatomy. Current alignment relies on concurrent Magnetic Resonance Imaging (MRI) for registration, introducing financial, logistical, and throughput barriers. To overcome these challenges, we present Manifold Optimisation for Full-Waveform Inversion (MOFI), a method to register skull templates without using a guidance image. Our method aligns the skull template by minimising the difference between simulated and observed radio-frequency acoustic data. We demonstrate that MOFI accurately recovers the position of skull templates in silico and in vitro, offering an alternative to MRI guidance-based registration. These results indicate that MOFI has the potential to be a practical alternative to MRI-guided approaches, reducing the barriers to wider clinical adoption of transcranial ultrasound.

physics.med-ph

Convolve and Conquer: Data Comparison with Wiener Filters

Quantitative evaluations of differences and/or similarities between data samples define and shape optimisation problems associated with learning data distributions. Current methods to compare data often suffer from limitations in capturing such distributions or lack desirable mathematical properties for optimisation (e.g. smoothness, differentiability, or convexity). In this paper, we introduce a new method to measure (dis)similarities between paired samples inspired by Wiener-filter theory. The convolutional nature of Wiener filters allows us to comprehensively compare data samples in a globally correlated way. We validate our approach in four machine learning applications: data compression, medical imaging imputation, translated classification, and non-parametric generative modelling. Our results demonstrate increased resolution in reconstructed images with better perceptual quality and higher data fidelity, as well as robustness against translations, compared to conventional mean-squared-error analogue implementations.

cs.LG

Stride: a flexible platform for high-performance ultrasound computed tomography

Advanced ultrasound computed tomography techniques like full-waveform inversion are mathematically challenging and orders of magnitude more computationally expensive than conventional ultrasound imaging methods. This computational and algorithmic complexity, and a lack of open-source libraries in this field, represent a barrier preventing the generalised adoption of these techniques, slowing the pace of research and hindering reproducibility. Consequently, we have developed Stride, an open-source Python library for the solution of large-scale ultrasound tomography problems. On one hand, Stride provides high-level interfaces and tools for expressing the types of optimisation problems encountered in medical ultrasound tomography. On the other, these high-level abstractions seamlessly integrate with high-performance wave-equation solvers and with scalable parallelisation routines. The wave-equation solvers are generated automatically using Devito, a domain specific language, and the parallelisation routines are provided through the custom actor-based library Mosaic. Through a series of examples, we show how Stride can handle realistic tomographic problems, in 2D and 3D, providing intuitive and flexible interfaces that scale from a local multi-processing environment to a multi-node high-performance cluster.

physics.med-ph

Benchmark problems for transcranial ultrasound simulation: Intercomparison of compressional wave models

Computational models of acoustic wave propagation are frequently used in transcranial ultrasound therapy, for example, to calculate the intracranial pressure field or to calculate phase delays to correct for skull distortions. To allow intercomparison between the different modeling tools and techniques used by the community, an international working group was convened to formulate a set of numerical benchmarks. Here, these benchmarks are presented, along with intercomparison results. Nine different benchmarks of increasing geometric complexity are defined. These include a single-layer planar bone immersed in water, a multi-layer bone, and a whole skull. Two transducer configurations are considered (a focused bowl and a plane piston), giving a total of 18 permutations of the benchmarks. Eleven different modeling tools are used to compute the benchmark results. The models span a wide range of numerical techniques, including the finite-difference time-domain method, angular-spectrum method, pseudospectral method, boundary-element method, and spectral-element method. Good agreement is found between the models, particularly for the position, size, and magnitude of the acoustic focus within the skull. When comparing results for each model with every other model in a cross comparison, the median values for each benchmark for the difference in focal pressure and position are less than 10\% and 1 mm, respectively. The benchmark definitions, model results, and intercomparison codes are freely available to facilitate further comparisons.

physics.comp-ph

Spatial response identification enables robust experimental ultrasound computed tomography

Ultrasound computed tomography techniques have the potential to provide clinicians with 3D, quantitative and high-resolution information of both soft and hard tissues such as the breast or the adult human brain. Their practical application requires accurate modelling of the acquisition setup: the spatial location, orientation, and impulse response of each ultrasound transducer. However, existing calibration methods fail to accurately characterise these transducers unless their size can be considered negligible when compared to the dominant wavelength, which reduces signal-to-noise ratios below usable levels in the presence of high-contrast tissues such as the skull. In this paper, we introduce a methodology that can simultaneously estimate the location, orientation, and impulse response of the ultrasound transducers in a single calibration. We do this by extending spatial response identification, an algorithm that we have recently proposed to estimate transducer impulse responses. Our proposed methodology replaces the transducers in the acquisition device with a surrogate model whose effective response matches the experimental data by fitting a numerical model of wave propagation. This results in a flexible and robust calibration procedure that can accurately predict the behaviour of the ultrasound acquisition device without ever having to know where the real transducers are or their individual impulse response. Experimental results using a ring acquisition system show that spatial response identification produces calibrations of significantly higher quality than standard methodologies across all transducers, both in transmission and in reception. Experimental full-waveform inversion reconstructions of a tissue-mimicking phantom demonstrate that spatial response identification generates more accurate reconstructions than those produced with standard calibration techniques.

eess.SP