High energy beam energy measurement with microwave-electron Compton backscattering

The uncertainty of the energy measurement of the electron beam on circular electron positron collider (CEPC) must be smaller than 10$\mathrm{MeV}$ to make sure the accurate measurement of the mass of the Higgs boson. In order to simplify the energy measurement system, a new method is proposed by fitting the Compton edge of the energy distribution of the gamma ray from a microwave-electron Compton scattering. With our method, the uncertainty of the energy measurement is 6$\mathrm{MeV}$ for the electron energy of $120\mathrm{GeV}$ in the Higgs mode. In this system, the energy resolution of the gamma detection needs to reach $10^{-4}$. Therefore, only the high-purity germanium (HPGe) detector can meet the critical requirement. In a head-on collision mode, the initial photons should be microwave photons with the wavelength of 3.04 centimeters. A cylindrical resonant cavity with selected ${TM_{010}}$ mode is used to transmit microwaves. After the microwave-electron Compton backscattering, the scattered photons and the synchrotron-radiation background transmit a shielding structure and then are detected by a HPGe detector at the end of the beam line of the synchrotron-radiation applications. The hole radius in the side wall of the cavity is about $1.5\mathrm{mm}$ to allow the electron beam passing through. The results of the computer simulation technology (CST) software shows that the influence of the hole radius on the cavity field is negligible. The change of the resonance frequency can be easily corrected by fine-tuning the cavity size.

hep-ex↗

Commissioning of te China-ADS injector-I testing facility

The 10 MeV accelerator-driven subcritical system (ADS) Injector-I test stand at Institute of High Energy Physics (IHEP) is a testing facility dedicated to demonstrate one of the two injector design schemes [Injector Scheme-I, which works at 325 MHz], for the ADS project in China. The Injector adopted a four vane copper structure RFQ with output energy of 3.2 MeV and a superconducting (SC) section accommodating fourteen \b{eta}g=0.12 single spoke cavities, fourteen SC solenoids and fourteen cold BPMs. The ion source was installed since April of 2014, periods of commissioning are regularly scheduled between installation phases of the rest of the injector. Continuous wave (CW) beam was shooting through the injector and 10 MeV CW proton beam with average beam current around 2 mA was obtained recently. This contribution describe the results achieved so far and the difficulties encountered in CW commissioning.

physics.acc-ph↗

Impedance Measurements of the Extraction Kicker System for the Rapid Cycling Synchrotron of China Spallation Neutron Source

The fast extraction kicker system is one of the most important accelerator components, whose inner structure will be the main source of the impedance in the RCS. It is necessary to understand the kicker impedance before its installation into the tunnel. The conventional and improved wire methods are employed for the benchmarking impedance measurement results. The simulation and measurements confirm that the window-frame ferrite geometry and the end plate are the important structures causing the coupling impedance. The total impedance of the eight modules systems is determined by the scaling law from the measurement and the impedance measurement of the kicker system is summarized.

physics.acc-ph↗