Searcharxiv⌕ Search

arXiv subjects

Ozhan Koybasi

Publications and source records attributed to Ozhan Koybasi.

2 recordsLinked to original sources

Monolithic ultraviolet-to- near infrared photodetection enabled by an aluminium oxide photonic platform

Broadband photonic integrated circuits require waveguide platforms that combine low optical loss across a wide spectral range with integrated photodetection. Here we demonstrate a monolithically integrated atomic-layer-deposited (ALD) aluminium oxide (Al$_2$O$_3$)-on-silicon platform enabling waveguide-coupled photodetection from the ultraviolet to the near-infrared. The architecture employs evanescent coupling between low-loss Al$_2$O$_3$ waveguides and silicon p-i-n photodiodes. The platform supports photodetection at 375, 658 and 780 nm, extending integrated silicon photodetection into the ultraviolet. The devices exhibit linear photocurrent scaling with optical power, dark currents of approximately 2 pA at 50 V reverse bias and nanosecond-scale temporal response. We further demonstrate centimetre-scale ultraviolet Mach-Zehnder interferometer circuits with integrated photodiodes. The same detector architecture is implemented with Si$_3$N$_4$ waveguides, whereas the lower ultraviolet propagation loss of Al$_2$O$_3$ enables an approximately 15-fold higher photodetection response at 375 nm. These results establish ALD Al$_2$O$_3$ as a broadband integrated photonics platform for sensing, spectroscopy and quantum technologies.

physics.optics↗

Radiation Hard 3D Silicon Pixel Sensors for use in the ATLAS Detector at the HL-LHC

The High Luminosity LHC (HL-LHC) upgrade requires the planned Inner Tracker (ITk) of the ATLAS detector to tolerate extremely high radiation doses. Specifically, the innermost parts of the pixel system will have to withstand radiation fluences above $1\times10^{16}$ $n_{eq}cm^{-2}$. Novel 3D silicon pixel sensors offer a superior radiation tolerance compared to conventional planar pixel sensors, and are thus excellent candidates for the innermost parts of the ITk. This paper presents studies of 3D pixel sensors with pixel size $50 \times 50$ $μm^2$ mounted on the RD53A prototype readout chip. Following a description of the design and fabrication steps, Test Beam results are presented for unirradiated as well as heavily irradiated sensors. For particles passing at perpendicular incidence, it is shown that average efficiencies above 96% are reached for sensors exposed to fluences of $1\times10^{16}$ $n_{eq}cm^{-2}$ when biased to 80 $V$.

physics.ins-det↗