SearcharxivSearch

arXiv subjects

P Pivato

Publications and source records attributed to P Pivato.

3 recordsLinked to original sources

Precision measurements of the magnetic parameters of LISA Pathfinder test masses

A precise characterization of the magnetic properties of LISA Pathfinder free falling test-masses is of special interest for future gravitational wave observatory in space. Magnetic forces have an important impact on the instrument sensitivity in the low frequency regime below the millihertz. In this paper we report on the magnetic injection experiments performed throughout LISA Pathfinder operations. We show how these experiments allowed a high precision estimate of the instrument magnetic parameters. The remanent magnetic moment was found to have a modulus of $(0.245\pm0.081)\,\rm{nAm}^2$, the x-component of the background magnetic field within the test masses position was measured to be $(414 \pm 74)$ nT and its gradient had a value of $(-7.4\pm 2.1)\,μ$T/m. Finally, we also measured the test mass magnetic susceptibility to be $(-3.35\pm0.15)\times$10$^{-5}$ in the low frequency regime. All results are in agreement with on-ground estimates.

astro-ph.IM

Magnetic-induced force noise in LISA Pathfinder free-falling test masses

LISA Pathfinder was a mission designed to test key technologies required for gravitational wave detection in space. Magnetically driven forces play a key role in the instrument sensitivity in the low-frequency regime, which corresponds to the measurement band of interest for future space-borne gravitational wave observatories. Magnetic-induced forces couple to the test mass motion, introducing a contribution to the relative acceleration noise between the free falling test masses. In this Letter we present the first complete estimate of this term of the instrument performance model. Our results set the magnetic-induced acceleration noise during the February 2017 noise run of $\rm 0.25_{-0.08}^{+0.15}\,fm\,s^{-2}/\sqrt{Hz}$ at 1 mHz and $\rm 1.01_{-0.24}^{+0.73}\, fm\,s^{-2}/\sqrt{Hz}$ at 0.1 mHz. We also discuss how the non-stationarities of the interplanetary magnetic field can affect these values during extreme space weather conditions.

astro-ph.IM

Measuring the Galactic Cosmic Ray Flux with the LISA Pathfinder Radiation Monitor

Test mass charging caused by cosmic rays will be a significant source of acceleration noise for space-based gravitational wave detectors like LISA. Operating between December 2015 and July 2017, the technology demonstration mission LISA Pathfinder included a bespoke monitor to help characterise the relationship between test mass charging and the local radiation environment. The radiation monitor made in situ measurements of the cosmic ray flux while also providing information about its energy spectrum. We describe the monitor and present measurements which show a gradual 40% increase in count rate coinciding with the declining phase of the solar cycle. Modulations of up to 10% were also observed with periods of 13 and 26 days that are associated with co-rotating interaction regions and heliospheric current sheet crossings. These variations in the flux above the monitor detection threshold (approximately 70 MeV) are shown to be coherent with measurements made by the IREM monitor on-board the Earth orbiting INTEGRAL spacecraft. Finally we use the measured deposited energy spectra, in combination with a GEANT4 model, to estimate the galactic cosmic ray differential energy spectrum over the course of the mission.

astro-ph.IM