Searcharxiv⌕ Search

arXiv subjects

P. Ade

Publications and source records attributed to P. Ade.

At least 73 records · Page 4Linked to original sources

QUBIC IV: Performance of TES Bolometers and Readout Electronics

A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of 256 NbSi transition edge sensors (TES) cooled to 320 mK. The readout system is a 128:1 time domain multiplexing scheme based on 128 SQUIDs cooled at 1 K that are controlled and amplified by an SiGe application specific integrated circuit at 40 K. We report the performance of this readout chain and the characterization of the TES. The readout system has been functionally tested and characterized in the lab and in QUBIC. The low noise amplifier demonstrated a white noise level of 0.3 nV.Hz^-0.5. Characterizations of the QUBIC detectors and readout electronics includes the measurement of I-V curves, time constant and the noise equivalent power. The QUBIC TES bolometer array has approximately 80% detectors within operational parameters. It demonstrated a thermal decoupling compatible with a phonon noise of about 5.10^-17 W.Hz^-0.5 at 410 mK critical temperature. While still limited by microphonics from the pulse tubes and noise aliasing from readout system, the instrument noise equivalent power is about 2.10^-16 W.Hz^-0.5, enough for the demonstration of bolometric interferometry.

astro-ph.IM↗

QUBIC I: Overview and ScienceProgram

The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematic effects with those of bolometric detectors in terms of wide-band, background-limited sensitivity. The QUBIC synthesized beam has a frequency-dependent shape that results in the ability to produce maps of the CMB polarization in multiple sub-bands within the two physical bands of the instrument (150 and 220 GHz). These features make QUBIC complementary to other instruments and makes it particularly well suited to characterize and remove Galactic foreground contamination. In this article, first of a series of eight, we give an overview of the QUBIC instrument design, the main results of the calibration campaign, and present the scientific program of QUBIC including not only the measurement of primordial B-modes, but also the measurement of Galactic foregrounds. We give forecasts for typical observations and measurements: with three years of integration on the sky and assuming perfect foreground removal as well as stable atmospheric conditions from our site in Argentina, our simulations show that we can achieve a statistical sensitivity to the effective tensor-to-scalar ratio (including primordial and foreground B-modes) $σ(r)=0.015$.

astro-ph.IM↗

QUBIC V: Cryogenic system design and performance

Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interferometer for Cosmology) experiment: we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat, using two pulse-tube refrigerators to cool at ~3K a large (~1 m^3) volume, heavy (~165kg) instrument, including the cryogenic polarization modulator, the corrugated feedhorns array, and the lower temperature stages; a 4He evaporator cooling at ~1K the interferometer beam combiner; a 3He evaporator cooling at ~0.3K the focal-plane detector arrays. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33K, while the polarization modulator has been operated from a ~10K base temperature. The system has been tilted to cover the boresight elevation range 20 deg -90 deg without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.

astro-ph.IM↗

QUBIC VIII: Optical design and performance

The Q and U Bolometric Interferometer for Cosmology (QUBIC) is a ground-based experiment that aims to detect B-mode polarisation anisotropies in the CMB at angular scales around the l=100 recombination peak. Systematic errors make ground-based observations of B modes at millimetre wavelengths very challenging and QUBIC mitigates these problems in a somewhat complementary way to other existing or planned experiments using the novel technique of bolometric interferometry. This technique takes advantage of the sensitivity of an imager and the systematic error control of an interferometer. A cold reflective optical combiner superimposes there-emitted beams from 400 aperture feedhorns on two focal planes. A shielding system composedof a fixed groundshield, and a forebaffle that moves with the instrument, limits the impact of local contaminants. The modelling, design, manufacturing and preliminary measurements of the optical components are described in this paper.

astro-ph.IM↗

CONCERTO at APEX: installation and technical commissioning

We describe the deployment and first tests on Sky of CONCERTO, a large field-of-view (18.6arc-min) spectral-imaging instrument. The instrument operates in the range 130-310GHz from the APEX 12-meters telescope located at 5100m a.s.l. on the Chajnantor plateau. Spectra with R=1-300 are obtained using a fast (2.5Hz mechanical frequency) Fourier Transform Spectrometer (FTS), coupled to a continuous dilution cryostat with a base temperature of 60mK. Two 2152-pixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) are installed in the cryostat that also contains the cold optics and the front-end electronics. CONCERTO, installed in April 2021, generates more than 20k spectra per second during observations. We describe the final development phases, the installation and the first results obtained on Sky.

astro-ph.IM↗

GASTON: Galactic Star Formation with NIKA2. Evidence for the mass growth of star-forming clumps

Determining the mechanism by which high-mass stars are formed is essential for our understanding of the energy budget and chemical evolution of galaxies. By using the New IRAM KIDs Array 2 (NIKA2) camera on the Institut de Radio Astronomie Millimétrique (IRAM) 30-m telescope, we have conducted high-sensitivity and large-scale mapping of a fraction of the Galactic plane in order to search for signatures of the transition between the high- and low-mass star-forming modes. Here, we present the first results from the Galactic Star Formation with NIKA2 (GASTON) project, a Large Programme at the IRAM 30-m telescope which is mapping $\approx$2 deg$^2$ of the inner Galactic plane (GP), centred on $\ell$=23.9$^\circ$, $b$=0.05$^\circ$, as well as targets in Taurus and Ophiuchus in 1.15 and 2.00 mm continuum wavebands. In this paper we present the first of the GASTON GP data taken, and present initial science results. We conduct an extraction of structures from the 1.15 mm maps using a dendrogram analysis and, by comparison to the compact source catalogues from Herschel survey data, we identify a population of 321 previously-undetected clumps. Approximately 80 per cent of these new clumps are 70 $μ$m-quiet, and may be considered as starless candidates. We find that this new population of clumps are less massive and cooler, on average, than clumps that have already been identified. Further, by classifying the full sample of clumps based upon their infrared-bright fraction - an indicator of evolutionary stage - we find evidence for clump mass growth, supporting models of clump-fed high-mass star formation.

astro-ph.GA↗

QUBIC VI: cryogenic half wave plate rotator, design and performances

Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used technique is the Stokes Polarimetry that uses a rotating half-wave plate (HWP) and a linear polarizer to separate and modulate the polarization components with low residual cross-polarization. This paper describes the QUBIC Stokes Polarimeter highlighting its design features and its performances. A common systematic with these devices is the generation of large spurious signals synchronous with the rotation and proportional to the emissivity of the optical elements. A key feature of the QUBIC Stokes Polarimeter is to operate at cryogenic temperature in order to minimize this unwanted component. Moving efficiently this large optical element at low temperature constitutes a big engineering challenge in order to reduce friction power dissipation. Big attention has been given during the designing phase to minimize the differential thermal contractions between parts. The rotation is driven by a stepper motor placed outside the cryostat to avoid thermal load dissipation at cryogenic temperature. The tests and the results presented in this work show that the QUBIC polarimeter can easily achieve a precision below 0.1° in positioning simply using the stepper motor precision and the optical absolute encoder. The rotation induces only few mK of extra power load on the second cryogenic stage (~ 8 K).

astro-ph.IM↗

Exploiting NIKA2/XMM-Newton imaging synergy for intermediate mass, high-$z$ galaxy clusters within the NIKA2 SZ Large Program

High-resolution mapping of the intra-cluster medium (ICM) up to high redshift and down to low masses is crucial to derive accurate mass estimates of the galaxy cluster and to understand the systematic effects affecting cosmological studies based on galaxy clusters. We present a spatially-resolved Sunyaev-Zel'dovich (SZ)/X-ray analysis of ACT-CL J0215.4+0030, a high redshift ($z=0.865$) galaxy cluster of intermediate mass ($M_{500}\simeq3.5\times10^{14}\;\mathrm{M_\odot}$) observed as part of the ongoing NIKA2 SZ Large Program, a follow up of a representative sample of objects at $0.5 \leqslant z \leqslant 0.9$. In addition to the faintness and small angular size induced by its mass and redshift, the cluster is contaminated by point sources that significantly affect the SZ signal. Therefore, this is an interesting case study for the most challenging sources of the NIKA2 cluster sample. We present the NIKA2 observations of this cluster and the resulting data. We reconstruct the ICM pressure profile by performing a joint analysis of the SZ signal and of the point sources in the NIKA2 150 GHz map. We obtain high-quality estimates of the ICM thermodynamical properties with NIKA2. We compare the pressure profile extracted from the NIKA2 map to the pressure profile obtained from X-ray data only by deprojecting XMM-Newton observations of the cluster. We combine the NIKA2 pressure profile with the X-ray deprojected density to extract detailed information on the ICM. The radial distribution of its thermodynamic properties indicate that the cluster has a disturbed core. The hydrostatic mass of the cluster is to be compatible with estimations from SZ and X-rays scaling relations. We conclude that the NIKA2 SZ large program can deliver quality information on the thermodynamics of the ICM even for one of its faintest clusters, after a careful treatment of the contamination by point sources.

astro-ph.CO↗

A wide field-of-view low-resolution spectrometer at APEX: instrument design and science forecast

Characterise the large-scale structure in the Universe from present times to the high redshift epoch of reionisation is essential to constraining the cosmology, the history of star formation and reionisation, measuring the gas content of the Universe and obtaining a better understanding of the physical process that drive galaxy formation and evolution. Using the integrated emission from unresolved galaxies or gas clouds, line intensity mapping (LIM) provides a new observational window to measure the larger properties of structure. This very promising technique motivates the community to plan for LIM experiments. We describe the development of a large field-of-view instrument, named CONCERTO, operating in the range 130-310 GHz from the APEX 12-meters telescope. CONCERTO is a low-resolution spectrometer based on the Lumped Element Kinetic Inductance Detectors technology. Spectra are obtained using a fast Fourier Transform Spectrometer (FTS), coupled to a dilution cryostat with base temperature of 0.1K. Two 2 kilo-pixels arrays of LEKID are mounted inside the cryostat that also contains the cold optics and the front-end electronics. We present in detail the technological choices leading to the instrumental concept, together with the design and fabrication of the instrument and preliminary laboratory tests on the detectors. We also give our best estimates of CONCERTO sensitivity and give predictions for two of the main scientific goals of CONCERTO, i.e. a [CII]-intensity mapping survey and observations of galaxy clusters. We provide a detail description of the instrument design. Based on realistic comparisons with existing instruments developed by our group (NIKA, NIKA2, and KISS), and on laboratory detectors characterisation, we provide an estimate of CONCERTO sensitivity on sky. Finally, we describe in detail two out of the main science goals offered by CONCERTO at APEX.

astro-ph.IM↗

The XXL Survey XLIV. Sunyaev-Zel'dovich mapping of a low-mass cluster at z~1: a multi-wavelength approach

In this paper, we present resolved observations of the Sunyaev-Zel'dovich (SZ) effect, obtained with the NIKA2 camera, towards the cluster of galaxies XLSSC102, a relatively low-mass system ($M_{500} \sim 2 \times 10^{14}$ M$_{\odot}$) at $z = 0.97$ detected from the XXL survey. We combine NIKA2 SZ data, XMM-Newton X-ray data, and Megacam optical data to explore, respectively, the spatial distribution of the gas electron pressure, the gas density, and the galaxies themselves. We find significant offsets between the X-ray peak, the SZ peak, the brightest cluster galaxy, and the peak of galaxy density. Additionally, the galaxy distribution and the gas present elongated morphologies. This is interpreted as the sign of a recent major merging event, which induced a local boost of the gas pressure towards the north of XLSSC102 and stripped the gas out of the galaxy group. The NIKA2 data are also combined with XXL data to construct the thermodynamic profiles of XLSSC102, obtaining relatively tight constraints up to about $\sim r_{500}$, and revealing properties that are typical of disturbed systems. We also explore the impact of the cluster centre definition and the implication of local pressure substructure on the recovered profiles. Finally, we derive the global properties of XLSSC102 and compare them to those of high-mass-and-low-redshift systems, finding no strong evidence for non-standard evolution. We also use scaling relations to obtain alternative mass estimates from our profiles. The variation between these different mass estimates reflects the difficulty to accurately measure the mass of low-mass clusters at z$\sim$1, especially with low signal-to-noise ratio (S/N) data and for a disturbed system. However, it also highlights the strength of resolved SZ observations alone and in combination with survey-like X-ray data.

astro-ph.CO↗

QUBIC: the Q & U Bolometric Interferometer for Cosmology

The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addresses these requirements using an innovative approach combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with the deep control of systematics characteristic of interferometers. This makes QUBIC unique with respect to others classical imagers experiments devoted to the CMB polarization. In this contribution we report a description of the QUBIC instrument including recent achievements and the demonstration of the bolometric interferometry performed in lab. QUBIC will be deployed at the observation site in Alto Chorrillos, in Argentina at the end of 2019.

astro-ph.IM↗

Cluster cosmology with the NIKA2 SZ Large Program

The main limiting factor of cosmological analyses based on thermal Sunyaev-Zel'dovich (SZ) cluster statistics comes from the bias and systematic uncertainties that affect the estimates of the mass of galaxy clusters. High-angular resolution SZ observations at high redshift are needed to study a potential redshift or morphology dependence of both the mean pressure profile and of the mass-observable scaling relation used in SZ cosmological analyses. The NIKA2 camera is a new generation continuum instrument installed at the IRAM 30-m telescope. With a large field of view, a high angular resolution and a high-sensitivity, the NIKA2 camera has unique SZ mapping capabilities. In this paper, we present the NIKA2 SZ large program, aiming at observing a large sample of clusters at redshifts between 0.5 and 0.9, and the characterization of the first cluster oberved with NIKA2.

astro-ph.CO↗

Calibration and Performance of the NIKA2 camera at the IRAM 30-meter Telescope

NIKA2 is a dual-band millimetric continuum camera of 2900 Kinetic Inductance Detectors (KID), operating at $150$ and $260\,\rm{GHz}$, installed at the IRAM 30-meter telescope. We present the performance assessment of NIKA2 after one year of observation using a dedicated point-source calibration method, referred to as the \emph{baseline} method. Using a large data set acquired between January 2017 and February 2018 that span the whole range of observing elevations and atmospheric conditions encountered at the IRAM 30-m telescope, we test the stability of the performance parameters. We report an instantaneous field of view (FOV) of 6.5' in diameter, filled with an average fraction of $84\%$ and $90\%$ of valid detectors at $150$ and $260\,\rm{GHz}$, respectively. The beam pattern is characterized by a FWHM of $17.6'' \pm 0.1''$ and $11.1''\pm 0.2''$, and a beam efficiency of $77\% \pm 2\%$ and $55\% \pm 3\%$ at $150$ and $260\,\rm{GHz}$, respectively. The rms calibration uncertainties are about $3\%$ at $150\,\rm{GHz}$ and $6\%$ at $260\,\rm{GHz}$. The absolute calibration uncertainties are of $5\%$ and the systematic calibration uncertainties evaluated at the IRAM 30-m reference Winter observing conditions are below $1\%$ in both channels. The noise equivalent flux density (NEFD) at $150$ and $260\,\rm{GHz}$ are of $9 \pm 1\, \rm{mJy}\cdot s^{1/2}$ and $30 \pm 3\, \rm{mJy}\cdot s^{1/2}$. This state-of-the-art performance confers NIKA2 with mapping speeds of $1388 \pm 174$ and $111 \pm 11 \,\rm{arcmin}^2\cdot \rm{mJy}^{-2}\cdot \rm{h}^{-1}$ at $150$ and $260\,\rm{GHz}$. With these unique capabilities of fast dual-band mapping at high (better that 18'') angular resolution, NIKA2 is providing an unprecedented view of the millimetre Universe.

astro-ph.IM↗

Observing with NIKA2Pol from the IRAM 30m telescope. Early results on the commissioning phase

The NIKA2 polarization channel at 260 GHz (1.15 mm) has been proposed primarily to observe galactic star-forming regions and probe the critical scales between 0.01-0.05 pc at which magnetic field lines may channel the matter of interstellar filaments into growing dense cores. The NIKA2 polarimeter consists of a room temperature continuously rotating multi-mesh HWP and a cold polarizer that separates the two orthogonal polarizations onto two 260 GHz KIDs arrays. We describe in this paper the preliminary results obtained during the most recent commissioning campaign performed in December 2018. We concentrate here on the analysis of the extended sources, while the observation of compact sources is presented in a companion paper [12]. We present preliminary NIKA2 polarization maps of the Crab nebula. We find that the integrated polarization intensity flux measured by NIKA2 is consistent with expectations.In terms of polarization angle, we are still limited by systematic uncertainties that will be further investigated in the forthcoming commissioning campaigns.

astro-ph.IM↗

QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB

QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province. The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors (TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at 1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K allowing to reach an unprecedented multiplexing (MUX) factor equal to 128. The QUBIC experiment is currently being characterized in the lab with a reduced number of detectors before upgrading to the full instrument. I will present the last results of this characterization phase with a focus on the detectors and readout system.

astro-ph.IM↗

Debris disks around stars in the NIKA2 era

The new NIKA2 camera at the IRAM 30m radiotelescope was used to observe three known debris disks in order to constrain the SED of their dust emission in the millimeter wavelength domain. We have found that the spectral index between the two NIKA2 bands (1mm and 2mm) is consistent with the Rayleigh-Jeans regime (lambda^{-2}), unlike the steeper spectra (lambda^{-3}) measured in the submillimeter-wavelength domain for two of the three disks $-$ around the stars Vega and HD107146. We provide a succesful proof of concept to model this spectral inversion in using two populations of dust grains, those smaller and those larger than a grain radius a0 of 0.5mm. This is obtained in breaking the slope of the size distribution and the functional form of the absorption coefficient of the standard model at a0. The third disk - around the star HR8799 - does not exhibit this spectral inversion but is also the youngest.

astro-ph.EP↗

The NIKA polarimeter on science targets. Crab nebula observations at 150 GHz and dual-band polarization images of Orion Molecular Cloud OMC-1

We present here the polarization system of the NIKA camera and give a summary of the main results obtained and performed studies on Orion and the Crab nebula. The polarization system was equipped with a room temperature continuously rotating multi-mesh half wave plate and a grid polarizer facing the NIKA cryostat window. NIKA even though less sensitive than NIKA2 had polarization capability in both 1 and 2 millimiter bands. NIKA polarization observations demonstrated the ability of such a technology in detecting the polarization of different targets, compact and extended sources like the Crab nebula and Orion Molecular Cloud region OMC-1. These measurements together with the developed techniques to deal with systematics, opened the way to the current observations of NIKA2 in polarization that will provide important advances in the studies of galactic and extra-galactic emission and magnetic fields.

astro-ph.GA↗

NIKA2 mapping and cross-instrument SED extraction of extended sources with Scanamorphos

The steps taken to tailor to NIKA2 observations the Scanamorphos algorithm (initially developed to subtract low-frequency noise from Herschel on-the-fly observations) are described, focussing on the consequences of the different instrument architecture and observation strategy. The method, making the most extensive use of the redundancy built in the multi-scan coverage with large arrays of a given region of the sky, is applicable to extended sources, while the pipeline is so far optimized for compact sources. An example of application is given. A related tool to build consistent broadband SEDs from 60 microns to 2 mm, combining Herschel and NIKA2 data, has also been developed. Its main task is to process the data least affected by low-frequency noise and coverage limitations (i.e. the Herschel data) through the same transfer function as the NIKA2 data, simulating the same scan geometry and applying the same noise and atmospheric signal as extracted from the 1 mm and 2 mm data.

astro-ph.IM↗