SearcharxivSearch

arXiv subjects

P. Alfaurt

Publications and source records attributed to P. Alfaurt.

5 recordsLinked to original sources

High-precision beam profile measurement with a microchannel-plate detector in the high magnetic field of the WISArD experiment

We present the development and characterization of a compact low-energy ion beam diagnostic for the WISArD (Weak Interaction Studies with $\mathrm{^{32}Ar}$ Decay) experiment at ISOLDE/CERN. The microchannel plate (MCP) detector, which is configured in a Z-stack and has a resistive position sensitive anode, was tested with both stable and radioactive beams. This work focuses on the image reconstruction method, which corrects the pincushion distortion inherent to the square-shaped resistive anode, and investigates the influence of the magnetic field on the detector performance. Our results demonstrate that the detector achieves beam profile measurements with sub-millimeter accuracy, while coping with the spatial and high-magnetic field (4 T) constraints of the experiment. These capabilities meet the precision requirements of the WISArD experiment for extracting the modified beta-neutrino angular correlation coefficient, \~a$_{\beta\nu}$, with an uncertainty of 0.1%.

physics.ins-det

First simultaneous measurement of the gamma-ray and neutron emission probabilities in inverse kinematics at a heavy-ion storage ring

The probabilities for gamma-ray and particle emission as a function of the excitation energy of a decaying nucleus are valuable observables for constraining the ingredients of the models that describe the de-excitation of nuclei near the particle emission threshold. These models are essential in nuclear astrophysics and applications. In this work, we have for the first time simultaneously measured the gamma-ray and neutron emission probabilities of 208Pb. The measurement was performed in inverse kinematics at the Experimental Storage Ring (ESR) of the GSI/FAIR facility, where a 208Pb beam interacted through the 208Pb(p,p') reaction with a hydrogen gas jet target. Instead of detecting the gamma-rays and neutrons emitted by 208Pb, we detected the heavy beam-like residues produced after gamma and neutron emission. These heavy residues were fully separated by a dipole magnet of the ESR and were detected with outstanding efficiencies. The comparison of the measured probabilities with model calculations has allowed us to test and select different descriptions of the gamma-ray strength function and the nuclear level density available in the literature.

nucl-ex

First measurement of the neutron-emission probability with a surrogate reaction in inverse kinematics at a heavy-ion storage ring

Neutron-induced reaction cross sections of short-lived nuclei are imperative to understand the origin of heavy elements in stellar nucleosynthesis and for societal applications, but their measurement is extremely complicated due to the radioactivity of the targets involved. One way of overcoming this issue is to combine surrogate reactions with the unique possibilities offered by heavy-ion storage rings. In this work, we describe the first surrogate-reaction experiment in inverse kinematics, which we successfully conducted at the Experimental Storage Ring (ESR) of the GSI/FAIR facility, using the 208Pb(p,p') reaction as a surrogate for neutron capture on 207Pb. Thanks to the outstanding detection efficiencies possible at the ESR, we were able to measure for the first time the neutron-emission probability as a function of the excitation energy of 208Pb. We have used this probability to select different descriptions of the gamma-ray strength function and nuclear level density, and provide reliable results for the neutron-induced radiative capture cross section of 207Pb at energies for which no experimental data exist.

nucl-ex

Status on the DESIR High Resolution Separator Commissioning

Many nuclear reactions used to create radioactive isotopes for nuclear research produce, in addition to the isotope of interest, many contaminants, which are often produced in much larger amounts than the isotope of interest. Many installations using the ISOL approach are therefore equipped with high-resolution mass separators to remove at least isotopes with a different mass number. In the present paper, we present the results of the commissioning of the DESIR HRS presently under development at LP2I Bordeaux (formerly CENBG). Optical aberrations are corrected up to 3rd order and a mass resolution of M/$Δ$M of 25000 is reached with a transmission of about 70% for a 133Cs+ beam at 25 keV.

physics.ins-det

Simultaneous Measurements of the Beta Neutrino Angular Correlation in $^{32}$Ar Pure Fermi and Pure Gamow-Teller Transitions using Beta-Proton Coincidences

We report first time measurements of the beta-neutrino angular correlation based on the kinetic energy shift of protons emitted in parallel or anti-parallel directions with respect to the positron in the beta decay of $^{32}$Ar. This proof of principle experiment provided simultaneous measurements for the superallowed 0$^+$~$\rightarrow$~0$^+$ transition followed by a 3356~keV proton emission and for a Gamow-Teller transition followed by a 2123~keV proton emission. The results, respectively ${\tilde a_{βν}}=1.01(3)_{(stat)}(2)_{(syst)}$ and ${\tilde a_{βν}}=-0.22(9)_{(stat)}(2)_{(syst)}$, are found in agreement with the Standard Model. A careful analysis of the data shows that future measurements can reach a precision level of 10$^{-3}$ for both pure Fermi and pure Gamow-Teller decay channels, providing new constraints on both scalar and tensor weak interactions.

nucl-ex