Searcharxiv⌕ Search

arXiv subjects

P. C. F. Di Stefano

Publications and source records attributed to P. C. F. Di Stefano.

At least 19 recordsLinked to original sources

Scintillating properties of Cs${_2}$ZrCl${_6}$ crystals in the temperature range of 5-300 K

A new comprehensive study on the Cs${_2}$ZrCl${_6}$ (CZC) crystal scintillating properties under different types of irradiation was performed over a wide temperature range from 5 to 300 K. The light yield (LY) at room temperature (RT), measured under irradiation by 662 keV $γ$ quanta of $^{137}$Cs, was evaluated to be 53,300 $\pm$ 4,700 photons/MeV corresponding to approximately 71% of its estimated absolute value. The maximum light emission was observed in the temperature interval 135-165 K, where the LY reached 56,900 photons/MeV and 19,700 photons/MeV for $γ$ quanta and $α$ particles, respectively. The quenching factor (QF) for $α$ particles increases smoothly from QF = 0.30 at RT to QF = 0.36 at 135 K. The shape of scintillation pulses induced by $α$ particles is characterized by three time-constants (0.3, 2.5 and 11.8 $μ$s at RT), whereas the average pulse of $γ$ induced events is characterized by two time-constants (1.3 and 11.5 $μ$s at RT). At the same time, scintillating properties and pulse-shape discrimination capability of the CZC exhibit an acute deterioration at temperatures below 135 K. The optimal operating conditions to maximize the scintillating performance of undoped CZC crystals are discussed.

physics.ins-det↗

Rare $^{40}$K decay with implications for fundamental physics and geochronology

Potassium-40 is a widespread, naturally occurring isotope whose radioactivity impacts subatomic rare-event searches, nuclear structure theory, and estimated geological ages. A predicted electron-capture decay directly to the ground state of argon-40 has never been observed. The KDK (potassium decay) collaboration reports strong evidence of this rare decay mode. A blinded analysis reveals a non-zero ratio of intensities of ground-state electron-captures ($I_{\text{EC}^0}$) over excited-state ones ($I_\text{EC*}$) of $ I_{\text{EC}^0} / I_\text{EC*} = 0.0095 \stackrel{\text{stat}}{\pm} 0.0022 \stackrel{\text{sys}}{\pm} 0.0010 $ (68% C.L.), with the null hypothesis rejected at 4$σ$. In terms of branching ratio, this signal yields $I_{\text{EC}^0} = 0.098\% \stackrel{\text{stat}}{\pm} 0.023\% \stackrel{\text{sys}}{\pm} 0.010\% $, roughly half of the commonly used prediction, with consequences for various fields [L. Hariasz et al., companion paper, DOI: 10.1103/PhysRevC.108.014327].

nucl-ex↗

Precision measurement of $^{65}$Zn electron-capture decays with the KDK coincidence setup

$^{65}$Zn is a common calibration source, moreover used as a radioactive tracer in medical and biological studies. In many cases, $γ$-spectroscopy is a preferred method of $^{65}$Zn standardization, which relies directly on the branching ratio of $J π(^{65}\text{Zn} ) = 5/2^- \rightarrow J π(^{65}\text{Cu}) = 5/2^- $ via electron capture (EC*). We measure the relative intensity of this branch to that proceeding directly to the ground state (EC$^0$) using a novel coincidence technique, finding $I_{\text{EC}^0}/I_{\text{EC*}} = 0.9684 \pm 0.0018$. Re-evaluating the decay scheme of $^{65}$Zn by adopting the commonly evaluated branching ratio of $I_{β^+}= 1.4271(7)\%$ we obtain $I_{\text{EC*}} = (50.08 \pm 0.06)\%$, and $I_\text{EC^0} = (48.50 \pm 0.06) \%$. The associated 1115 keV gamma intensity agrees with the previously reported NNDC value, and is now accessible with a factor of ~2 increase in precision. Our re-evaluation removes reliance on the deduction of this gamma intensity from numerous measurements, some of which disagree and depend directly on total activity determination. The KDK experimental technique provides a new avenue for verification or updates to the decay scheme of $^{65}$Zn, and is applicable to other isotopes.

nucl-ex↗

Evidence for ground-state electron capture of $^{40}$K

Potassium-40 is a widespread isotope whose radioactivity impacts estimated geological ages spanning billions of years, nuclear structure theory, and subatomic rare-event searches - including those for dark matter and neutrinoless double-beta decay. The decays of this long-lived isotope must be precisely known for its use as a geochronometer, and to account for its presence in low-background experiments. There are several known decay modes for $^{40}$K, but a predicted electron-capture decay directly to the ground state of argon-40 has never been observed, while theoretical predictions span an order of magnitude. The KDK Collaboration reports on the first observation of this rare decay, obtained using a novel combination of a low-threshold X-ray detector surrounded by a tonne-scale, high-efficiency $γ$-ray tagger at Oak Ridge National Laboratory. A blinded analysis reveals a distinctly nonzero ratio of intensities of ground-state electron-captures ($I_{\text{EC}^0}$) over excited-state ones ($I_{\text{EC}^*}$) of $I_{\text{EC}^0} / I_{\text{EC}^*}=0.0095\stackrel{\text{stat}}{\pm}0.0022\stackrel{\text{sys}}{\pm}0.0010$ (68% CL), with the null hypothesis rejected at 4$σ$ [Stukel et al., DOI:10.1103/PhysRevLett.131.052503]. This unambiguous signal yields a branching ratio of $I_{\text{EC}^0}=0.098\%\stackrel{\text{stat}}{\pm}0.023\%\stackrel{\text{sys}}{\pm}0.010$, roughly half of the commonly used prediction. This first observation of a third-forbidden unique electron capture improves understanding of low-energy backgrounds in dark-matter searches and has implications for nuclear-structure calculations. A shell-model based theoretical estimate for the $0νββ$ decay half-life of calcium-48 is increased by a factor of $7^{+3}_{-2}$. Our nonzero measurement shifts geochronological ages by up to a percent; implications are illustrated for Earth and solar system chronologies.

nucl-ex↗

Development and characterization of a slow wavelength shifting coating for background rejection in liquid argon detectors

We describe a technique, applicable to liquid-argon-based dark matter detectors, allowing for discrimination of alpha-decays in detector regions with incomplete light collection from nuclear-recoil-like events. Nuclear recoils and alpha events preferentially excite the liquid argon (LAr) singlet state, which has a decay time of ~6 ns. The wavelength-shifter TPB, which is typically applied to the inside of the active detector volume to make the LAr scintillation photons visible, has a short re-emission time that preserves the LAr scintillation timing. We developed a wavelength-shifting polymeric film - pyrene-doped polystyrene - for the DEAP-3600 detector and describe the production method and characterization. At liquid argon temperature, the film's re-emission timing is dominated by a modified exponential decay with time constant of 279(14) ns and has a wavelength-shifting efficiency of 46.4(2.9) % relative to TPB, measured at room temperature. By coating the detector neck (a region outside the active volume where the scintillation light collection efficiency is low) with this film, the visible energy and the scintillation pulse shape of alpha events in the neck region are modified, and we predict that through pulse shape discrimination, the coating will afford a suppression factor of O($10^{5}$) against these events.

physics.ins-det↗

Investigation of the cryogenic scintillation of pure and doped sodium-iodine

We have studied the scintillation of pure and doped sodium iodide crystals handled in low humidity conditions under external $α$ and $γ$ excitation from room temperature down to 4K. The light yield of pure sodium iodide was seen to increase at low temperatures by a factor 30 compared to room temperature, up to a maximum of 40 photons/keV under $γ$ excitation at 60K, stabilizing to 30 photons/keV at lower temperatures. Thallium doped sodium iodide fluctuates by 20% around the room temperature value, stabilizing at 40 photons/keV at low temperature. $α/ γ$ quenching factor stabilizes at roughly 0.7 for both materials beneath 50K. Time constants of both materials slow greatly at low temperature, reaching tens of microseconds. Cryogenic applications of these materials are complexified by their mechanical fragility and hygroscopicity.

physics.ins-det↗

Ultraviolet-induced fluorescence of poly(methyl methacrylate) compared to 1,1,4,4-tetraphenyl-1,3-butadiene down to 4 K

Several particle-physics experiments use poly(methyl methacrylate) (a.k.a. PMMA or acrylic) vessels to contain liquid scintillators. Superluminal charged particles emitted from radioactive impurities in or near the acrylic can emit Cherenkov radiation in the ultraviolet (UV) spectra range. If acrylic fluoresces in the visible range due to this UV light, it could be a source of background in experiments where the main signal is visible scintillation light, or UV scintillation light that is absorbed and re-emitted at visible wavelengths by a wavelength shifter. Some of these experiments operate at low temperature. The fluorescence of these materials could change with temperature so we have studied the fluorescence of the acrylic used in the DEAP-3600 experiment down to a temperature of 4 K, and compared it to the common wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene (TPB). The light yield and wavelength spectra of these materials were characterized by exciting the sample with 285 nm UV light which acted as a proxy for Cherenkov light in the detector. Spectral measurements indicate at least part of the fluorescence of the acrylic is due to additives. Time-resolved measurements show the light yields of our acrylic sample, TPB sample, and the relative light between both samples, all increase when cooling down. At room temperature, the light yield of our acrylic sample relative to the TPB sample is 0.3 %, while it reaches 0.5 % at 4 K. The main fluorescence time constant of the acrylic is less than a few nanoseconds.

physics.ins-det↗

Fluorescence of pyrene-doped polystyrene films from room temperature down to 4 K for wavelength-shifting applications

In liquid argon-based particle detectors, slow wavelength shifters (WLSs) could be used alongside the common, nanosecond scale, WLS tetraphenyl butadiene (TPB) for background mitigation purposes. At room temperature, pyrene has a moderate fluorescence light yield (LY) and a time constant of the order of hundreds of nanoseconds. In this work, four pyrene-doped polystyrene films with various purities and concentrations were characterized in terms of LY and decay time constants in a range of temperature between 4 K and 300 K under ultraviolet excitation. These films were found to have a LY between 35 and 50% of that of evaporated TPB. All light yields increase when cooling down, while the decays slow down. At room temperature, we observed that pyrene purity is strongly correlated with emission lifetime: highest obtainable purity samples were dominated by decays with emission time constants of $\sim$ 250-280 ns, and lower purity samples were dominated by an $\sim$ 80 ns component. One sample was investigated further to better understand the monomer and excimer emissions of pyrene. The excimer-over-monomer intensity ratio decreases when the temperature goes down, with the monomer emission dominating below $\sim$ 87 K.

physics.ins-det↗

A novel experimental system for the KDK measurement of the $^{40}$K decay scheme relevant for rare event searches

Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpreting certain results or can lead to lack of precision depending on the field and analysis technique. The KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited $^{40}$K source inside the Modular Total Absorption Spectrometer. This setup has been characterized in terms of energy calibration, gamma tagging efficiency, live time and false negatives and positives. A complementary, homogeneous, method is also discussed; it employs a KSr$_2$I$_5$:Eu scintillator as source and detector.

physics.ins-det↗

First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector

We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.

hep-ex↗

Temperature-dependent fluorescence emission spectra of acrylic (PMMA) and tetraphenyl butadiene (TPB) excited with UV light

Acrylic (poly(methyl methacrylate) or PMMA) is commonly used as a vessel to hold scintillating liquids in rare-event searches. Certain types of PMMA can fluoresce with a low efficiency at room temperature. We have investigated the fluorescence spectra under 280nm ultraviolet (UV) excitation of the PMMA used in the DEAP dark matter search at various low temperatures. Fluorescence of this PMMA is observed, with an increasing intensity as the sample is cooled from a temperature of 300K down to 4K. The common wavelength-shifter tetraphenyl butadiene (TPB) is also measured for use as a reference.

physics.ins-det↗

Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors

The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.

physics.ins-det↗

Low-Mass Dark Matter Search with CDMSlite

The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$

astro-ph.CO↗

The KDK (potassium decay) experiment

Potassium-40 (${}^{40}$K) is a background in many rare-event searches and may well play a role in interpreting results from the DAMA dark-matter search. The electron-capture decay of ${}^{40}$K to the ground state of ${}^{40}$Ar has never been measured and contributes an unknown amount of background. The KDK (potassium decay) collaboration will measure this branching ratio using a ${}^{40}$K source, an X-ray detector, and the Modular Total Absorption Spectrometer at Oak Ridge National Laboratory.

nucl-ex↗

Results from the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at Soudan

We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times 10^{-44}$ ($1.0 \times 10^{-44}$) cm$^2$ at 46 GeV/$c^2$. These results set the strongest limits for WIMP--germanium-nucleus interactions for masses $>$12 GeV/$c^2$.

hep-ex↗

Projected Sensitivity of the SuperCDMS SNOLAB experiment

SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.

physics.ins-det↗

Dark matter effective field theory scattering in direct detection experiments

We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.

astro-ph.CO↗

A Multi-Channel Setup to Study Fractures in Scintillators

To investigate fractoluminescence in scintillating crystals used for particle detection, we have developed a multi-channel setup built around samples of double-cleavage drilled compression (DCDC) geometry in a controllable atmosphere. The setup allows the continuous digitization over hours of various parameters, including the applied load, and the compressive strain of the sample, as well as the acoustic emission. Emitted visible light is recorded with nanosecond resolution, and crack propagation is monitored using infrared lighting and camera. An example of application to Bi4Ge3O12 (BGO) is provided.

physics.ins-det↗