SearcharxivSearch

arXiv subjects

P. Cancio Pastor

Publications and source records attributed to P. Cancio Pastor.

3 recordsLinked to original sources

Measuring molecular frequencies in the 1--10 μm range at 11-digits accuracy

Mid infrared (MIR) photonics is a key region for molecular physics [1]. High-resolution spectroscopy in the 1--10 μm region, though, has never been fully tackled for the lack of widely-tunable and practical light sources. Indeed, all solutions proposed thus far suffer from at least one of three issues: they are feasible only in a narrow spectral range; the power available for spectroscopy is limited; the frequency accuracy is poor. Here, we present a setup for high-resolution spectroscopy that can be applied in the whole 1--10 μm range by combining the power of quantum cascade lasers (QCLs) and the accuracy achievable by difference frequency generation using an OP-GaP crystal. The frequency is measured against a primary frequency standard using the Italian metrological fibre link network. We demonstrate the performance of the setup by measuring a vibrational transition in a highly-excited metastable state of CO around 6 μm with 11 digits of precision, four orders of magnitude better than the value available in the literature [2].

physics.atom-ph

Quantum electrodynamic calculation of the hyperfine structure of 3He

The combined fine and hyperfine structure of the $2^3P$ states in $^3$He is calculated within the framework of nonrelativistic quantum electrodynamics. The calculation accounts for the effects of order $mα^6$ and increases the accuracy of theoretical predictions by an order of magnitude. The results obtained are in good agreement with recent spectroscopic measurements in $^3$He.

physics.atom-ph

Frequency metrology of helium around 1083 nm and determination of the nuclear charge radius

We measure the absolute frequency of seven out of the nine allowed transitions between the 2$^3${\it S} and 2$^3${\it P} hyperfine manifolds in a metastable $^3$He beam by using an optical frequency comb synthesizer-assisted spectrometer. The relative uncertainty of our measurements ranges from $1\times 10^{-11}$ to $5\times 10^{-12}$, which is, to our knowledge, the most precise result for any optical $^3$He transition to date. The resulting $2^3${\it P}-2$^3${\it S} centroid frequency is $276\,702\,827\,204.8\,(2.4)$kHz. Comparing this value with the known result for the $^4$He centroid and performing {\em ab initio} QED calculations of the $^4$He-$^3$He isotope shift, we extract the difference of the squared nuclear charge radii $δr^2$ of $^3$He and $^4$He. Our result for $δr^2=1.074 (3)$ fm$^2$ disagrees by about $4\,σ$ with the recent determination [R. van Rooij {\em et al.}, Science {\bf 333}, 196 (2011)].

physics.atom-ph