SearcharxivSearch

arXiv subjects

P. Cristaudo

Publications and source records attributed to P. Cristaudo.

4 recordsLinked to original sources

Simulation of the response of a diamond-based radiation detector to ultra-short and intense high-energy electron pulses

Single-crystal synthetic diamond sensors have been widely used in radiation dosimetry and beam diagnostics. The foreseen harsh radiation environment in electron-positron colliders at the luminosity frontier requires a thorough investigation of diamond's response to large radiation burst, in particular, to intense high-energy electron pulses. In this article, a two-step numerical simulation approach (Sentaurus~+~LTspice) is proposed to explore this topic. Time response of the diamond detector is simulated via TCAD-Sentaurus while the transmission effect of the electronic circuit is taken into account using LTspice. Good agreement is observed between results of the numerical simulation and preliminary experimental data from detector's exposure to high-energy sub-picosecond electron pulses, on both the amplitude and the shape of the induced signals. This simulation combination is a novel approach to designing and optimising diamond detectors for radiation and beam loss monitoring in particle physics experiments.

physics.ins-det

Calibration of diamond detectors for dosimetry in beam-loss monitoring

Artificially-grown diamond crystals have unique properties that make them suitable as solid-state particle detectors and dosimeters in high-radiation environments. We have been using sensors based on single-crystal diamond grown by chemical vapour deposition for dosimetry and beam-loss monitoring at the SuperKEKB collider. Here we describe the assembly and the suite of test and calibration procedures adopted to characterise the diamond-based detectors of this monitoring system. We report the results obtained on 28 detectors and assess the stability and uniformity of response of these devices.

physics.ins-det

Performance of the diamond-based beam-loss monitor system of Belle II

We designed, constructed and have been operating a system based on single-crystal synthetic diamond sensors, to monitor the beam losses at the interaction region of the SuperKEKB asymmetric-energy electron-positron collider. The system records the radiation dose-rates in positions close to the inner detectors of the Belle II experiment, and protects both the detector and accelerator components against destructive beam losses, by participating in the beam-abort system. It also provides complementary information for the dedicated studies of beam-related backgrounds. We describe the performance of the system during the commissioning of the accelerator and during the first physics data taking.

physics.ins-det

First Measurements of Beam Backgrounds at SuperKEKB

The high design luminosity of the SuperKEKB electron-positron collider is expected to result in challenging levels of beam-induced backgrounds in the interaction region. Properly simulating and mitigating these backgrounds is critical to the success of the Belle~II experiment. We report on measurements performed with a suite of dedicated beam background detectors, collectively known as BEAST II, during the so-called Phase 1 commissioning run of SuperKEKB in 2016, which involved operation of both the high energy ring (HER) of 7 GeV electrons as well as the low energy ring (LER) of 4 GeV positrons. We describe the BEAST II detector systems, the simulation of beam backgrounds, and the measurements performed. The measurements include standard ones of dose rates versus accelerator conditions, and more novel investigations, such as bunch-by-bunch measurements of injection backgrounds and measurements sensitive to the energy spectrum and angular distribution of fast neutrons. We observe beam-gas, Touschek, beam-dust, and injection backgrounds. We do not observe significant synchrotron radiation, as expected. Measured LER beam-gas backgrounds and Touschek backgrounds in both rings are slightly elevated, on average three times larger than the levels predicted by simulation. HER beam-gas backgrounds are on on average two orders of magnitude larger than predicted. Systematic uncertainties and channel-to-channel variations are large, so that these excesses constitute only 1-2 sigma level effects. Neutron background rates are higher than predicted and should be studied further. We will measure the remaining beam background processes, due to colliding beams, in the imminent commissioning Phase 2. These backgrounds are expected to be the most critical for Belle II, to the point of necessitating replacement of detector components during the Phase 3 (full-luminosity) operation of SuperKEB.

physics.ins-det