SearcharxivSearch

arXiv subjects

P. E. Mueller

Publications and source records attributed to P. E. Mueller.

At least 19 recordsLinked to original sources

Gamma Backgrounds for Experiments at the High Flux Isotope Reactor

This article describes the deployment of a germanium detector at Oak Ridge National Lab's High Flux Isotope Reactor (HFIR) for the purpose of understanding the energy and spatial distribution of the gamma field in the experiment hall where the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT) took data and future neutrino experiments could be located. The sources from both the reactor and the neutron beamlines are described in detail, along with their temporal variations due to reactor power and their spatial variations due to the geometry of the beamlines and building materials in the vicinity. Additionally, a shielding study was performed to assess the amount that backgrounds in tens of keV range can be mitigated. This work helps inform backgrounds for future experiments at reactors such as IBD-based neutrino measurements and CEvNS measurements.

hep-ex

Probing Long-Lived Particle Production in Muon Decays at the SNS with a Highly Capable Hydrocarbon Detector

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is a prolific muon producer, making it an ideal location for studying dark sector particles produced in muon decays at rest. In this paper, we explore sub-GeV dark particle detection possibilities in a tons-scale, highly capable hydrocarbon scintillator ($HC^2$) detector at the SNS. We consider a search for $e^+e^-$ final states produced by decays of long-lived, $O(10-100)$ MeV axion-like particles and heavy neutral leptons. The $HC^2$ technology space, exemplified by the PROSPECT and Mobile Antineutrino Demonstrator detectors, offers strong rejection capabilities for the cosmic ray backgrounds that would normally dominate this search. By benchmarking on-surface cosmic ray signatures with data from PROSPECT at ORNL, we generate robust predictions for a multi-year SNS deployment of a range of $HC^2$ detector implementations. Results indicate the potential for order-of-magnitude improvements in sensitivity to axion-like particles and heavy neutral leptons in the 10-100 MeV mass regime compared to current global limits. We also comment on the neutrino detection possibilities of a $HC^2$ deployment at the SNS.

hep-ex

New Deep Learning Data Analysis Method for PROSPECT using GAPE: Genetic Algorithm Powered Evolution

We propose a genetic algorithm powered evolution (GAPE) method to create deep learning solutions for energy and position estimation for reactor antineutrino interactions in the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT) at the highly enriched High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. We also apply GAPE to create classification models to distinguish signatures of inverse beta decay (IBD) interactions of reactor antineutrinos from common background types. The GAPE method can also be adopted for optimization of other types of problems that utilize machine learning (ML) models for particle physics applications. When applied in the PROSPECT context, we find that the models selected by GAPE can, in some cases, outperform the traditional models previously used for PROSPECT data analysis. In particular, when benchmarked against conventional PROSPECT neutrino identification pathways using the same underlying information, the classifier offers the promise of improving the signal-to-background ratio by nearly 2.8 times. Performance biases uncovered during initial IBD classifier validation were primarily caused by differences in time-dependent response between background and signal training datasets. Biases were effectively mitigated through a data-period-specific training regimen, offering a pathway towards realizing an unbiased IBD signal classifier for future reactor neutrino datasets.

physics.data-an

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT's Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe a on-beam excess of 20.6 +7.1 -6.3 counts with a total exposure of 10.22 GWhkg and we reject the no-CEvNS hypothesis with 3.9 sigma significance. The result agrees with the predicted standard model of particle physics signal rate within 2 sigma.

hep-ex

From Commissioning to Precision Data-Taking: Resolving Operational Challenges in the Nab Detector Systems

Our understanding of the weak mixing of quarks, described by the Cabibbo Kobayashi Maskawa (CKM) matrix, currently presents an anomaly. Thanks to major strides in both theory and experiment, improved precision in determinations of the first row of matrix elements has revealed disagreement with the expectation of unitarity. The Nab experiment at the Spallation Neutron Source is designed to precisely extract the first matrix element $V_{ud}$ and shed light on experimental tensions within the neutron beta decay dataset. Nab's asymmetric spectrometer allows coincident reconstruction of the decay proton and electron energies, which will be used to determine the electron-neutrino correlation coefficient, and thus (with the neutron lifetime) determine $V_{ud}$. This unique approach has provided a more comprehensive view of neutron beta decay, including a first observation of the full momentum phase space of the decay above detector thresholds and limits on exotic neutron states. Recent upgrades to the Nab detector system have improved the robustness and stability of the detector performance in terms of proton detection efficiency, noise performance, and detector segment availability, setting the stage for high precision physics data-taking.

physics.ins-det

Final Search for Short-Baseline Neutrino Oscillations with the PROSPECT-I Detector at HFIR

The PROSPECT experiment is designed to perform precise searches for antineutrino disappearance at short distances (7 - 9~m) from compact nuclear reactor cores. This Letter reports results from a new neutrino oscillation analysis performed using the complete data sample from the PROSPECT-I detector operated at the High Flux Isotope Reactor in 2018. The analysis uses a multi-period selection of inverse beta decay neutrino interactions with reduced backgrounds and enhanced statistical power to set limits on electron-flavor disappearance caused by mixing with sterile neutrinos with 0.2 - 20 eV$^2$ mass splittings. Inverse beta decay positron energy spectra from six different reactor-detector distance ranges are found to be statistically consistent with one another, as would be expected in the absence of sterile neutrino oscillations. The data excludes at 95% confidence level the existence of sterile neutrinos in regions above 3~eV$^2$ previously unexplored by terrestrial experiments, including all space below 10~eV$^2$ suggested by the recently strengthened Gallium Anomaly. The best-fit point of the Neutrino-4 reactor experiment's claimed observation of short-baseline oscillation is ruled out at more than five standard deviations.

hep-ex

Machine Learning for Single-Ended Event Reconstruction in PROSPECT Experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, was a segmented antineutrino detector that successfully operated at the High Flux Isotope Reactor in Oak Ridge, TN, during its 2018 run. Despite challenges with photomultiplier tube base failures affecting some segments, innovative machine learning approaches were employed to perform position and energy reconstruction, and particle classification. This work highlights the effectiveness of convolutional neural networks and graph convolutional networks in enhancing data analysis. By leveraging these techniques, a 3.3\% increase in effective statistics was achieved compared to traditional methods, showcasing their potential to improve analysis performance. Furthermore, these machine learning methodologies offer promising applications for other segmented particle detectors, underscoring their versatility and impact.

physics.data-an

Reactor Antineutrino Directionality Measurement with the PROSPECT-I Detector

The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. In this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of $ϕ= 40.8\unicode{xB0} \pm 0.7\unicode{xB0}$ and $θ= 98.6\unicode{xB0} \pm 0.4\unicode{xB0}$, the PROSPECT-I detector is able to reconstruct an average neutrino direction of $ϕ= 39.4\unicode{xB0} \pm 2.9\unicode{xB0}$ and $θ= 97.6\unicode{xB0} \pm 1.6\unicode{xB0}$. This measurement is made with approximately 48000 Inverse Beta Decay signal events and is the most precise directional reconstruction of reactor antineutrinos to date.

nucl-ex

The 3He(\vec n,p)3H parity-conserving asymmetry

Recently, the n$^3$He collaboration reported a measurement of the parity-violating (PV) proton directional asymmetry $A_{\mathrm {PV}} = (1.55\pm 0.97~\mathrm {(st\ at)} \pm 0.24~\mathrm {(sys)})\times 10^{-8}$ in the capture reaction of ${}^3$He$(\vec {n},{\mathrm p}){}^3$H at meV incident neutron energies. The result increased the limited inventory of precisely measured and calculable PV observables in few-body systems required to further understand the structure of hadronic weak interaction. In this letter, we report the experimental and theoretical investigation of a parity conserving (PC) asymmetry $A_{\mathrm {PC}}$ in the same reaction (the first ever measured PC observable at meV neutron energies). As a result of S- and P-wave mixing in the reaction, the $A_{\mathrm {PC}}$ is inversely proportional to the neutron wavelength $λ$. The experimental value is $(λ\times A_{\mathrm {PC}})\equivβ= (-1.97 \pm 0.28~\mathrm{(stat)}\pm 0.12~\mathrm{(sys)}) \times 10^{-6}$ Amstrongs. We present results for a theoretical analysis of this reaction by solving the four-body scattering problem within the hyperspherical harmonic method. We find that in the ${}^3$He$(\vec {n},{\mathrm p}){}^3$H reaction, $A_{\mathrm {PC}}$ depends critically on the energy and width of the close $0^-$ resonant state of ${}^4$He, resulting in a large sensitivity to the spin-orbit components of the nucleon-nucleon force and even to the three-nucleon force. The analysis of the accurately measured $A_{\mathrm {PC}}$ and $A_{\mathrm {PV}}$ using the same few-body theoretical models gives essential information needed to interpret the PV asymmetry in the ${}^3$He$(\vec {n}, {\mathrm p}){}^3$H reaction.

nucl-ex

Measurement of the Electron-Neutrino Charged-Current Cross Sections on ${}^{127}$I with the COHERENT NaI$ν$E detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ${}^{127}$I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy ($\leq$ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of $9.2^{+2.1}_{-1.8} \times 10^{-40}$ cm$^2$. This corresponds to a value that is $\sim$41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on $^{127}$I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be $5.2^{+3.4}_{-3.1} \times 10^{-40}$ and $2.2^{+3.5}_{-2.2} \times 10^{-40}$ cm$^2$, respectively.

nucl-ex

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several beyond-the-standard-model scenarios such as neutrino non-standard interactions and accelerator-produced dark matter. This detector's performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of CsI nuclei and detection of neutrinos from a core-collapse supernova.

hep-ex

Measurement of ${}^{nat}$Pb($ν_e$,X$n$) production with a stopped-pion neutrino source

Using neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL), the COHERENT collaboration has studied the Pb($ν_e$,X$n$) process with a lead neutrino-induced-neutron (NIN) detector. Data from this detector are fit jointly with previously collected COHERENT data on this process. A combined analysis of the two datasets yields a cross section that is $0.29^{+0.17}_{-0.16}$ times that predicted by the MARLEY event generator using experimentally-measured Gamow-Teller strength distributions, consistent with no NIN events at 1.8$σ$. This is the first inelastic neutrino-nucleus process COHERENT has studied, among several planned exploiting the high flux of low-energy neutrinos produced at the SNS.

hep-ex

Final Measurement of the U235 Antineutrino Energy Spectrum with the PROSPECT-I Detector at HFIR

This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely U235-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. The reconstructed energy spectrum is unfolded into antineutrino energy and compared with both the Huber-Mueller model and a spectrum from a commercial reactor burning multiple fuel isotopes. A local excess over the model is observed in the 5MeV to 7MeV energy region. Comparison of the PROSPECT results with those from commercial reactors provides new constraints on the origin of this excess, disfavoring at 2.2 and 3.2 standard deviations the hypotheses that antineutrinos from U235 are solely responsible and non-contributors to the excess observed at commercial reactors respectively.

nucl-ex

COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils

Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in "D. Akimov et al 2022 JINST 17 P10034". We share the data in the form of raw ADC waveforms, provide benchmark values, and share plots to enhance the transparency and reproducibility of our results. This document describes the contents of the data release as well as guidance on the use of the data.

physics.ins-det

Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. The expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

physics.ins-det

First Probe of Sub-GeV Dark Matter Beyond the Cosmological Expectation with the COHERENT CsI Detector at the SNS

The COHERENT collaboration searched for scalar dark matter particles produced at the Spallation Neutron Source with masses between 1 and 220~MeV/c$^2$ using a CsI[Na] scintillation detector sensitive to nuclear recoils above 9~keV$_\text{nr}$. No evidence for dark matter is found and we thus place limits on allowed parameter space. With this low-threshold detector, we are sensitive to coherent elastic scattering between dark matter and nuclei. The cross section for this process is orders of magnitude higher than for other processes historically used for accelerator-based direct-detection searches so that our small, 14.6~kg detector significantly improves on past constraints. At peak sensitivity, we reject the flux consistent with the cosmologically observed dark-matter concentration for all coupling constants $α_D<0.64$, assuming a scalar dark-matter particle. We also calculate the sensitivity of future COHERENT detectors to dark-matter signals which will ambitiously test multiple dark-matter spin scenarios.

hep-ex

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

physics.ins-det

PROSPECT-II Physics Opportunities

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum from $^{235}$U, and demonstrated the observation of reactor antineutrinos in an aboveground detector with good energy resolution and well-controlled backgrounds. The PROSPECT collaboration is now preparing an upgraded detector, PROSPECT-II, to probe yet unexplored parameter space for sterile neutrinos and contribute to a full resolution of the Reactor Antineutrino Anomaly, a longstanding puzzle in neutrino physics. By pressing forward on the world's most precise measurement of the $^{235}$U antineutrino spectrum and measuring the absolute flux of antineutrinos from $^{235}$U, PROSPECT-II will sharpen a tool with potential value for basic neutrino science, nuclear data validation, and nuclear security applications. Following a two-year deployment at HFIR, an additional PROSPECT-II deployment at a low enriched uranium reactor could make complementary measurements of the neutrino yield from other fission isotopes. PROSPECT-II provides a unique opportunity to continue the study of reactor antineutrinos at short baselines, taking advantage of demonstrated elements of the original PROSPECT design and close access to a highly enriched uranium reactor core.

hep-ex