SearcharxivSearch

arXiv subjects

P. Falferi

Publications and source records attributed to P. Falferi.

At least 19 recordsLinked to original sources

Synthetic-lattice Bloch wave dynamics in a single-mode microwave resonator

Frequency-based synthetic dimensions are a promising avenue for expanding the dimensionality of photonic systems. In this work, we show how a tilted synthetic lattice is naturally realised by periodically modulating a single-mode resonator under a coherent monochromatic drive. We theoretically study the Bloch wave dynamics in the tilted synthetic lattice, which gives rise to peculiar features in the spectral distribution of the cavity field. Our predictions are experimentally confirmed using a planar tunable superconducting microwave resonator.

cond-mat.mes-hall

Search for Axion dark matter with the QUAX-LNF tunable haloscope

We report the first experimental results obtained with the new haloscope of the QUAX experiment located at Laboratori Nazionali di Frascati of INFN (LNF). The haloscope is composed of a OFHC Cu resonant cavity cooled down to about 30 mK and immersed in a magnetic field of 8 T. The cavity frequency was varied in a 6 MHz range between 8.831496 and 8.83803 GHz. This corresponds to a previously unprobed mass range between 36.52413 and 36.5511 $\mu$eV. We don't observe any excess in the power spectrum and set limits on the axion-photon coupling in this mass range down to $g_{a\gamma\gamma} < 0.861 \times 10^{-13}$ GeV$^{-1}$ with the confidence level set at $90\%$.

physics.ins-det

Search for galactic axions with a traveling wave parametric amplifier

A traveling wave parametric amplifier has been integrated in the haloscope of the QUAX experiment. A search for dark matter axions has been performed with a high Q dielectric cavity immersed in a 8 T magnetic field and read by a detection chain having a system noise temperature of about 2.1 K at the frequency of 10.353 GHz. Scanning has been conducted by varying the cavity frequency using sapphire rods immersed into the cavity. At multiple operating frequencies, the sensitivity of the instrument was at the level of viable axion models.

hep-ex

Search for galactic axions with a high-Q dielectric cavity

A haloscope of the QUAX--$a\gamma$ experiment, composed of an high-Q resonant cavity immersed in a 8 T magnet and cooled to $\sim 4.5$~K is operated to search for galactic axion with mass $m_a\simeq42.8~\mu\text{eV}$. The design of the cavity with hollow dielectric cylinders concentrically inserted in a OFHC Cu cavity, allowed us to maintain a loaded quality-factor Q $\sim 300000$ during the measurements in presence of magnetic field. Through the cavity tuning mechanism it was possible to modulate the resonance frequency of the haloscope in the region $10.35337-10.35345$~GHz and thus acquire different dataset at different resonance frequencies. Acquiring each dataset for about 50 minutes, combining them and correcting for the axion's signal estimation-efficiency we set a limit on the axion-photon coupling $g_{a\gamma\gamma}< 0.731\times10^{-13}$ GeV$^{-1}$ with the confidence level set at $90\%$.

hep-ex

Progress in the development of a KITWPA for the DARTWARS project

DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) is a three years project that aims to develop high-performing innovative Traveling Wave Parametric Amplifiers (TWPAs) for low temperature detectors and qubit readout (C-band). The practical development follows two different promising approaches, one based on the Josephson junctions (TWJPA) and the other one based on the kinetic inductance of a high-resistivity superconductor (KITWPA). This paper presents the advancements made by the DARTWARS collaboration to produce a first working prototype of a KITWPA.

quant-ph

Ultra low noise readout with travelling wave parametric amplifiers: the DARTWARS project

The DARTWARS project has the goal of developing high-performing innovative travelling wave parametric amplifiers with high gain, large bandwidth, high saturation power, and nearly quantum-limited noise. The target frequency region for its applications is 5 - 10 GHz, with an expected noise temperature of about 600 mK. The development follows two different approaches, one based on Josephson junctions and one based on kinetic inductance of superconductors. This contribution mainly focuses on the Josephson travelling wave parametric amplifier, presenting its design, preliminary measurements and the test of homogeneity of arrays of Josephson junctions.

quant-ph

A high-Q microwave dielectric resonator for axion dark matter haloscopes

The frequency band 1-15 GHz provides exciting prospects for resonant axion haloscopes as indicated by cosmological and astrophysical arguments. Among the challenges currently addressed to reach the required sensitivity, the development of high quality factor cavities that tolerate multi-Tesla fields plays a central role. We report a 3D resonator based on a right circular copper cavity with hollow cylinders that confine higher order modes around the cylinder axis. Its effective volume at 10.3\,GHz is $3.4 \cdot 10^{-2}$ liters, and under an 8\,T-field we measured an internal quality factor of more than 9 millions. These parameters demonstrate the potential of this unique resonator to probe galactic dark matter axion at remarkable scan rates of 15\,MHz/day when the cavity is readout by a quantum-limited receiver.

physics.ins-det

Detector Array Readout with Traveling Wave Amplifiers

Noise at the quantum limit over a large bandwidth is a fundamental requirement for future applications operating at millikelvin temperatures, such as the neutrino mass measurement, the next-generation x-ray observatory, the CMB measurement, the dark matter and axion detection, and the rapid high-fidelity readout of superconducting qubits. The read out sensitivity of arrays of microcalorimeter detectors, resonant axion-detectors, and qubits, is currently limited by the noise temperature and bandwidth of the cryogenic amplifiers. The DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project has the goal of developing high-performing innovative traveling wave parametric amplifiers (TWPAs) with a high gain, a high saturation power, and a quantum-limited or nearly quantum-limited noise. The practical development follows two different promising approaches, one based on the Josephson junctions and the other one based on the kinetic inductance of a high-resistivity superconductor. In this contribution we present the aims of the project, the adopted design solutions and preliminary results from simulations and measurements.

cond-mat.supr-con

Bimodal Approach for Noise Figures of Merit Evaluation in Quantum-Limited Josephson Traveling Wave Parametric Amplifiers

The advent of ultra-low noise microwave amplifiers revolutionized several research fields demanding quantum-limited technologies. Exploiting a theoretical bimodal description of a linear phase-preserving amplifier, in this contribution we analyze some of the intrinsic properties of a model architecture (i.e., an rf-SQUID based Josephson Traveling Wave Parametric Amplifier) in terms of amplification and noise generation for key case study input states (Fock and coherents). Furthermore, we present an analysis of the output signals generated by the parametric amplification mechanism when thermal noise fluctuations feed the device.

cond-mat.supr-con

Search for invisible axion dark matter of mass m$_a=43~\mu$eV with the QUAX--$a\gamma$ experiment

A haloscope of the QUAX--$a\gamma$ experiment composed of an oxygen-free high thermal conductivity-Cu cavity inside an 8.1 T magnet and cooled to $\sim200$ mK is put in operation for the search of galactic axion with mass $m_a\simeq43~\mu\text{eV}$. The power emitted by the resonant cavity is amplified with a Josephson parametric amplifier whose noise fluctuations are at the standard quantum limit. With the data collected in about 1 h at the cavity frequency $\nu_c=10.40176$ GHz, the experiment reaches the sensitivity necessary for the detection of galactic QCD-axion, setting the $90\%$ confidence level limit to the axion-photon coupling $g_{a\gamma\gamma}<0.639\times10^{-13}$ GeV$^{-1}$.

hep-ex

Search of spin-dependent fifth forces with precision magnetometry

Spin-dependent fifth-forces are associated with particles beyond the standard model. In particular, light pseudo-scalar bosons mediate long-range forces, allowing mass to interact with spins. The search of these interactions can be performed by periodically varying the distance between a source mass and a spin ensemble, in order to modulate the force intensity and detect it with precision magnetometry techniques. In our setup the force arises from room temperature lead masses and is detected in a paramagnetic crystal at 4.2\,K, whose magnetisation is monitored by a SQUID-based magnetometer with the sensitivity of $53\,\mathrm{aT/\sqrt{Hz}}$. Our measurement places the most stringent constraints on a spin-mass interaction in the ranges 1\,cm to 10\,m and 10\,km to 300\,km, improving existing limits up to more than two orders of magnitude. We show that this experimental technique may be further leveraged to explore a vast region of the fifth force's parameter space, with an interaction range longer than a few centimetres.

hep-ex

Realization of a high quality factor resonator with hollow dielectric cylinders for axion searches

The realization and characterization of a high quality factor resonator composed of two hollow-dielectric cylinders with its pseudo-TM$_{030}$ mode resonating at 10.9 GHz frequency is discussed. The quality factor was measured at the temperatures 300 K and 4 K obtaining $\mbox{Q}_{300\mbox{K}}=(150,000\pm 2,000)$ and $\mbox{Q}_{4\mbox{K}}=(720,000\pm 10,000)$respectively, the latter corresponding to a gain of one order of magnitude with respect to a traditional copper cylindrical-cavity with the corresponding TM$_{010}$ mode resonating at the same frequency. The implications to dark-matter axion-searches with cavity experiments are discussed showing that the gain in quality factor is not spoiled by a reduced geometrical coupling $C_{030}$ of the cavity mode to the axion field. This reduction effect is estimated to be at most 20%. Numerical simulations show that frequency tuning of several hundreds MHz is feasible.

physics.ins-det

Narrowing the parameter space of collapse models with ultracold layered force sensors

Despite the unquestionable empirical success of quantum theory, witnessed by the recent uprising of quantum technologies, the debate on how to reconcile the theory with the macroscopic classical world is still open. Spontaneous collapse models are one of the few testable solutions so far proposed. In particular, the continuous spontaneous localization (CSL) model has become subject of an intense experimental research. Experiments looking for the universal force noise predicted by CSL in ultrasensitive mechanical resonators have recently set the strongest unambiguous bounds on CSL; further improving these experiments by direct reduction of mechanical noise is technically challenging. Here, we implement a recently proposed alternative strategy, that aims at enhancing the CSL noise by exploiting a multilayer test mass attached on a high quality factor microcantilever. The test mass is specifically designed to enhance the effect of CSL noise at the characteristic length $r_c=10^{-7}$ m. The measurements are in good agreement with pure thermal motion for temperatures down to 100 mK. From the absence of excess noise we infer a new bound on the collapse rate at the characteristic length $r_c=10^{-7}$ m, which improves over previous mechanical experiments by more than one order of magnitude. Our results are explicitly challenging a well-motivated region of the CSL parameter space proposed by Adler.

quant-ph

Ultralow mechanical damping with Meissner-levitated ferromagnetic microparticles

Levitated nanoparticles and microparticles are excellent candidates for the realization of extremely isolated mechanical systems, with a huge potential impact in sensing applications and in quantum physics. Magnetic levitation based on static fields is a particularly interesting approach, due to the unique property of being completely passive and compatible with low temperatures. Here, we show experimentally that micromagnets levitated above type-I superconductors feature very low damping at low frequency and low temperature. In our experiment, we detect 5 out of 6 rigid-body mechanical modes of a levitated ferromagnetic microsphere, using a dc SQUID (Superconducting Quantum Interference Device) with a single pick-up coil. The measured frequencies are in agreement with a finite element simulation based on ideal Meissner effect. For two specific modes we find further substantial agreement with analytical predictions based on the image method. We measure damping times $τ$ exceeding $10^4$ s and quality factors $Q$ beyond $10^7$, improving by $2-3$ orders of magnitude over previous experiments based on the same principle. We investigate the possible residual loss mechanisms besides gas collisions, and argue that much longer damping time can be achieved with further effort and optimization. Our results open the way towards the development of ultrasensitive magnetomechanical sensors with potential applications to magnetometry and gravimetry, as well as to fundamental and quantum physics.

quant-ph

High quality factor photonic cavity for dark matter axion searches

Searches for dark matter axion involve the use of microwave resonant cavities operating in a strong magnetic field. Detector sensitivity is directly related to the cavity quality factor, which is limited, however, by the presence of the external magnetic field. In this paper we present a cavity of novel design whose quality factor is not affected by a magnetic field. It is based on a photonic structure by the use of sapphire rods. The quality factor at cryogenic temperature is in excess of $5 \times 10^5$ for a selected mode.

physics.ins-det

Axion search with a quantum-limited ferromagnetic haloscope

A ferromagnetic axion haloscope searches for Dark Matter in the form of axions by exploiting their interaction with electronic spins. It is composed of an axion-to-electromagnetic field transducer coupled to a sensitive rf detector. The former is a photon-magnon hybrid system, and the latter is based on a quantum-limited Josephson parametric amplifier. The hybrid system consists of ten 2.1 mm diameter YIG spheres coupled to a single microwave cavity mode by means of a static magnetic field. Our setup is the most sensitive rf spin-magnetometer ever realized. The minimum detectable field is $5.5\times10^{-19}\,$T with 9 h integration time, corresponding to a limit on the axion-electron coupling constant $g_{aee}\le1.7\times10^{-11}$ at 95% CL. The scientific run of our haloscope resulted in the best limit on DM-axions to electron coupling constant in a frequency span of about 120 MHz, corresponding to the axion mass range $42.4$-$43.1\,μ$eV. This is also the first apparatus to perform an axion mass scanning by changing the static magnetic field.

hep-ex

KLASH Conceptual Design Report

The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals that started a real race towards their discovery. This paper is the Conceptual Design Report of the KLASH (KLoe magnet for Axion SearcH) experiment at the Laboratori Nazionali di Frascati (LNF). The idea of this experiment has been stimulated by the availability of the large volume superconducting magnet, with a moderate magnetic field of 0.6 T, used in the KLOE detector at the DAFNE collider. The main conclusion we draw from this report is the possibility to build and put in operation at LNF in 2-3 years a large haloscope with the sensitivity to KSVZ axions in the low mass range between 0.2 and 1 $μ$eV, complementary to that of other experiments. Timeline and cost are competitive with respect to other proposals in the same mass region thanks to the availability of most of the infrastructure, in particular the superconducting magnet and the cryogenics plant.

physics.ins-det

Galactic axions search with a superconducting resonant cavity

To account for the dark matter content in our Universe, post-inflationary scenarios predict for the QCD axion a mass in the range $(10-10^3)\,μ\mbox{eV}$. Searches with haloscope experiments in this mass range require the monitoring of resonant cavity modes with frequency above 5\,GHz, where several experimental limitations occur due to linear amplifiers, small volumes, and low quality factors of Cu resonant cavities. In this paper we deal with the last issue, presenting the result of a search for galactic axions using a haloscope based on a $36\,\mbox{cm}^3$ NbTi superconducting cavity. The cavity worked at $T=4\,\mbox{K}$ in a 2\,T magnetic field and exhibited a quality factor $Q_0= 4.5\times10^5$ for the TM010 mode at 9\,GHz. With such values of $Q$ the axion signal is significantly increased with respect to copper cavity haloscopes. Operating this setup we set the limit $g_{aγγ}<1.03\times10^{-12}\,\mbox{GeV}^{-1}$ on the axion photon coupling for a mass of about 37\,$μ$eV. A comprehensive study of the NbTi cavity at different magnetic fields, temperatures, and frequencies is also presented.

physics.ins-det