Searcharxiv⌕ Search

arXiv subjects

P. Göttlicher

Publications and source records attributed to P. Göttlicher.

29 records · Page 2Linked to original sources

Production of Z0 bosons in elastic and quasi-elastic ep collisions at HERA

The production of Z0 bosons in the reaction ep -> eZ0p*, where p* stands for a proton or a low-mass nucleon resonance, has been studied in ep collisions at HERA using the ZEUS detector. The analysis is based on a data sample collected between 1996 and 2007, amounting to 496 pb-1 of integrated luminosity. The Z0 was measured in the hadronic decay mode. The elasticity of the events was ensured by a cut on eta_max < 3.0, where eta_max is the maximum pseudorapidity of energy deposits in the calorimeter defined with respect to the proton beam direction. A signal was observed at the Z0 mass. The cross section of the reaction ep -> eZ0p* was measured to be sigma(ep -> eZ0p*) = 0.13 +/- 0.06 (stat.) +/- 0.01 (syst.) pb, in agreement with the Standard Model prediction of 0.16 pb. This is the first measurement of Z0 production in ep collisions.

hep-ex↗

Hadronic energy resolution of a highly granular scintillator-steel hadron calorimeter using software compensation techniques

The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to be approximately 58%/sqrt(E/GeV}. This resolution is improved to approximately 45%/sqrt(E/GeV) with software compensation techniques. These techniques take advantage of the event-by-event information about the substructure of hadronic showers which is provided by the imaging capabilities of the calorimeter. The energy reconstruction is improved either with corrections based on the local energy density or by applying a single correction factor to the event energy sum derived from a global measure of the shower energy density. The application of the compensation algorithms to Geant4 simulations yield resolution improvements comparable to those observed for real data.

physics.ins-det↗

Search for single-top production in ep collisions at HERA

A search for single-top production, $ep \rightarrow etX$, has been performed with the ZEUS detector at HERA using data corresponding to an integrated luminosity of $0.37\fbi$. No evidence for top production was found, consistent with the expectation from the Standard Model. Limits were computed for single-top production via flavour changing neutral current transitions. The result was combined with a previous ZEUS result yielding a total luminosity of 0.50fb-1. A 95% credibility level upper limit of 0.13 pb was obtained for the cross section at the centre-of-mass energy of $\sqrt{s}=315\gev$.

hep-ex↗

Exclusive electroproduction of two pions at HERA

The exclusive electroproduction of two pions in the mass range 0.4 < Mππ < 2.5 GeV has been studied with the ZEUS detector at HERA using an integrated luminosity of 82 pb-1. The analysis was carried out in the kinematic range of 2 < Q2 < 80 GeV2, 32 < W < 180 GeV and |t| < 0.6 GeV2, where Q2 is the photon virtuality, W is the photon-proton centre-of-mass energy and t is the squared four-momentum transfer at the proton vertex. The two-pion invariant-mass distribution is interpreted in terms of the pion electromagnetic form factor, |F(Mππ)|, assuming that the studied mass range includes the contributions of the ρ, ρ' and ρ" vector-meson states. The masses and widths of the resonances were obtained and the Q2 dependence of the cross-section ratios σ(ρ' \rightarrow ππ)/σ(ρ) and σ(ρ" \rightarrow ππ)/σ(ρ) was extracted. The pion form factor obtained in the present analysis is compared to that obtained in e+e- \rightarrow π+π-.

hep-ex↗

Electromagnetic response of a highly granular hadronic calorimeter

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM). A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes. The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described.

physics.ins-det↗

Measurement of heavy-quark jet photoproduction at HERA

Photoproduction of beauty and charm quarks in events with at least two jets has been measured with the ZEUS detector at HERA using an integrated luminosity of 133 $pb^{-1}$. The fractions of jets containing b and c quarks were extracted using the invariant mass of charged tracks associated with secondary vertices and the decay-length significance of these vertices. Differential cross sections as a function of jet transverse momentum, $p_{T}^{\text{jet}}$, and pseudorapidity, $η^{\text{jet}}$, were measured. The data are compared with previous measurements and are well described by next-to-leading-order QCD predictions.

hep-ex↗

Measurement of beauty production in deep inelastic scattering at HERA using decays into electrons

The production of beauty quarks in ep interactions has been studied with the ZEUS detector at HERA for exchanged four-momentum squared Q^2 > 10 GeV^2, using an integrated luminosity of 363 pb^{-1}. The beauty events were identified using electrons from semileptonic b decays with a transverse momentum 0.9 < p_T^e < 8 GeV and pseudorapidity |eta^e| < 1.5. Cross sections for beauty production were measured and compared with next-to-leading-order QCD calculations. The beauty contribution to the proton structure function F_2 was extracted from the double-differential cross section as a function of Bjorken-x and Q^2.

hep-ex↗

Study of the interactions of pions in the CALICE silicon-tungsten calorimeter prototype

A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the design of a full-sized detector. The interactions of pions in the Si-W calorimeter are therefore confronted with the predictions of various physical models implemented in the GEANT4 simulation framework.

physics.ins-det↗

Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype

An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab.

physics.ins-det↗

The ZEUS Forward Plug Calorimeter with Lead-Scintillator Plates and WLS Fiber Readout

A Forward Plug Calorimeter (FPC) for the ZEUS detector at HERA has been built as a shashlik lead-scintillator calorimeter with wave length shifter fiber readout. Before installation it was tested and calibrated using the X5 test beam facility of the SPS accelerator at CERN. Electron, muon and pion beams in the momentum range of 10 to 100 GeV/c were used. Results of these measurements are presented as well as a calibration monitoring system based on a $^{60}$Co source.

hep-ex↗